Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rianne van Melzen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nursing Accountability and Nurse Sensitive Outcomes: A Qualitative Focus Group Study With Nurses and Patients

    by Marije K. Valk, Hillegonda A. Stallinga, Marieke Timpener, Amber C. P. Boskma, Rianne V. A. N. Melzen, Evelyn J. Finnema

    Aim: To explore nursing accountability in relation to nurse sensitive outcomes (NSOs) from nurses' and patients' perspectives. Design: Qualitative descriptive study. Methods: Five focus groups were conducted (November–December 2024) at a university medical centre: four with nurses from different divisions and one with patients. Discussions were guided by empathy mapping and questions addressing five NSOs (pressure ulcers, delirium, catheter‐associated urinary tract infections, line infections, fall incidents). The Fundamentals of Care (FOC) Framework informed the analysis of empathy‐map data, while inductive analysis was applied to responses related to the NSOs. Results: Nurses and patients identified elements of nursing accountability, although their perspectives sometimes diverged. Nearly all FOC elements were represented in focus groups. For nurses, accountability emerged as a complex, layered concept. Across NSOs, implementation of interventions, especially for fall incidents, was emphasised. For pressure ulcers, prevention and recognition are key, while delirium was mainly seen as a medical accountability. Conclusion: NSOs provide measurable indicators of nursing accountability; however, current quantifications do not fully capture the complexity of nursing practice. Nurses emphasised accountability for their professional actions, including preventive care, while recognising patient outcomes may still be unfavourable. Although NSOs conceptually allow for a broader view, their present operationalisation supports only partial representation of accountability distribution and outcome evaluation. This underscores the need for broader approaches to evaluating nursing accountability. Implications for the Profession and/or Patient Care: Strengthening nursing accountability requires professional autonomy in multidisciplinary decision‐making. It also requires access to NSO data, the ability to interpret these data, and opportunities to act on influencing factors. Supporting reflective practice and constructive use of outcomes data are equally important. Future research should refine NSOs to better capture nursing contributions without narrowing the scope of the nursing profession. Impact: This study highlights the multifaceted nature of nursing accountability as perceived by nurses and patients, providing insights into the potential and limitations of nurse sensitive outcomes. Reporting Method: Standards for reporting qualitative research (SRQR). Patient or Public Contribution: This study did not include patient or public involvement in its design, conduct, or reporting.

  • Open Access

    Validity and Reliability of Wearable Sensors for Continuous Postoperative Vital Signs Monitoring in Patients Recovering from Trauma Surgery

    by Rianne van Melzen, Marjolein E. Haveman, Richte C. L. Schuurmann, Kai van Amsterdam, Mostafa El Moumni, Monique Tabak, Michel M. R. F. Struys, Jean-Paul P. M. de Vries

    (1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.


  • Open Access

    Postoperative continuous telemonitoring at the surgical ward

    by Rianne van Melzen, Marjolein Haveman

  • Open Access

    Implementing Wearable Sensors for Clinical Application at a Surgical Ward: Points to Consider before Starting

    by Rianne van Melzen, Marjolein E. Haveman, Richte C. L. Schuurmann, Michel M. R. F. Struys, Jean-Paul P. M. de Vries

    Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.


  • Open Access

    Determining the Reliable Measurement Period for Preoperative Baseline Values With Telemonitoring Before Major Abdominal Surgery: Pilot Cohort Study

    by Marjolein E Haveman, Rianne van Melzen, Mostafa El Moumni, Richte C L Schuurmann, Hermie J Hermens, Monique Tabak, Jean-Paul P M de Vries

    Background: Preoperative telemonitoring of vital signs, physical activity, and well-being might be able to optimize prehabilitation of the patient’s physical and mental condition prior to surgery, support setting alarms during in-hospital monitoring, and allow personalization of the postoperative recovery process. Objective: The primary aim of this study was to evaluate when and how long patients awaiting major abdominal surgery should be monitored to get reliable preoperative individual baseline values of heart rate (HR), daily step count, and patient-reported outcome measures (PROMs). The secondary aim was to describe the perioperative course of these measurements at home. Methods: In this observational single-center cohort study, patients used a wearable sensor during waking hours and reported PROMs (pain, anxiety, fatigue, nausea) on a tablet twice a day. Intraclass correlation coefficients (ICCs) were used to evaluate the reliability of mean values on 2 specific preoperative days (the first day of telemonitoring and the day before hospital admission) and randomly selected preoperative periods compared to individual reference values. Mean values of HR, step count, and PROMs per day were visualized in a boxplot from 14 days before hospital admission until 30 days after surgery. Results: A total of 16 patients were included in the data analyses. The ICCs of mean values on the first day of telemonitoring were 0.91 for HR, 0.71 for steps, and at least 0.86 for PROMs. The day before hospital admission showed reliability coefficients of 0.76 for HR, 0.71 for steps, and 0.92-0.99 for PROMs. ICC values of randomly selected measurement periods increased over the continuous period of time from 0.68 to 0.99 for HR and daily step counts. A lower bound of the 95% CI of at least 0.75 was determined after 3 days of measurements. The ICCs of randomly selected PROM measurements were 0.89-0.94. Visualization of mean values per day mainly showed variable preoperative daily step counts (median 2409, IQR 1735-4661 steps/day) and lower postoperative daily step counts (median 884, IQR 474-1605 steps/day). In addition, pain was visually reduced until 30 days after surgery at home. Conclusions: In this prospective pilot study, for patients awaiting major abdominal surgery, baseline values for HR and daily step count could be measured reliably by a wearable sensor worn for at least 3 consecutive days and PROMs during any preoperative day. No clear conclusions were drawn from the description of the perioperative course by showing mean values of HR, daily step count, and PROM values over time in the home situation.


  • Open Access

    Feasibility and patient’s experiences of perioperative telemonitoring in major abdominal surgery: an observational pilot study

    by Marjolein E. Haveman, Rianne van Melzen, Richte C.L. Schuurmann, Hermie J. Hermens, Monique Tabak, Jean-Paul P.M. de Vries

    Telemonitoring during the perioperative trajectory may improve patient outcomes and self-management. The aim of this study is to assess the feasibility of and patient’s experiences with telemonitor...


  • Open Access

    Continuous monitoring of vital signs with the Everion biosensor on the surgical ward: a clinical validation study

    by Marjolein E. Haveman, Rianne van Melzen, Richte C.L. Schuurmann, Mostafa El Moumni, Hermie J. Hermens, Monique Tabak, Jean-Paul P.M. de Vries

    Wearable sensors enable continuous vital sign monitoring, although information about their performance on nursing wards is scarce. Vital signs measured by telemonitoring and nurse measurements on a...