Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Raphael Chukwuka Nnachi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Making waves: toward systems-level interpretation of hormonal and endogenous biomarkers in wastewater-based epidemiology

    by Ahmed S. Abouhend, Walid A. Hanafy, Christopher Watt, Raphael C. Nnachi, Prashant Shenoy, Caitlyn S. Butler

  • Top Cited Papers
    Open Access

    Biosensors for rapid detection of bacterial pathogens in water, food and environment

    by Raphael Chukwuka Nnachi, Ning Sui, Bowen Ke, Zhenhua Luo, Nikhil Bhalla, Daping He, Zhugen Yang


  • Open Access

    An Estimation of the Anthropogenic Heat Emissions in Darwin City Using Urban Microclimate Simulations

    by Shehani Rajapaksha, Raphael Chukwuka Nnachi, Muhammad Atiq Ur Rehman Tariq, Anne W. M. Ng, Malik Muneeb Abid, Paras Sidiqui, Muhammad Farooq Rais, Erum Aamir, Luis Herrera Diaz, Saeed Kimiaei, et al.

    The energy consumption due to urbanization and man-made activities has resulted in production of waste, heat, and pollution in the urban environment. These have further resulted in undesirable environmental issues such as the production of excessive Anthropogenic Heat Emissions (AHE), thus leading to an increased Urban Heat Island (UHI) effect. The aim of this study was to estimate the total AHE based on the contribution of three major sources of waste heat generation in an urban environment, i.e., buildings, vehicular traffic, and human metabolism. Furthermore, a comparison of dominating anthropogenic heat factor of Darwin with that of other major international cities was carried out. Field measurements of microclimate (temperatures, humidity, solar radiation, and other factors of climate measures) were conducted along Smith Street, Darwin City. Then, surveys were conducted to collect information regarding the buildings, vehicle traffic and Human population (metabolism) in the study area. Each individual component of AHE was calculated based on a conceptual framework of the anthropogenic heat model developed within this study. The results showed that AHE from buildings is the most dominant factor influencing the total AHE in Darwin, contributing to about 87% to 95% of total AHE. This is followed by vehicular traffic (4–13%) and lastly, human metabolism (0.1–0.8%). The study also shows that Darwin gains an average of 990 Wm−2 solar power on a peak day. This study proves that building anthropogenic heat is the major dominating factor influencing the UHI in tropical urban climates.


  • Open Access

    Performance Evaluation of Phase Change Materials to Reduce the Cooling Load of Buildings in a Tropical Climate

    by Punita Sangwan, Hooman Mehdizadeh-Rad, Anne Wai Man Ng, Muhammad Atiq Ur Rehman Tariq, Raphael Chukwuka Nnachi

    Tropical region such as Darwin has similar weather patterns throughout the year, thus creating higher energy demands in residential buildings. Typically, buildings consume about 40 per cent of the total energy consumption for indoor heating and cooling. Therefore, building envelopes are linked with design strategies such as the use of thermal energy storage and phase change materials (PCM) to minimize this energy consumption by storing a large amount of thermal energy. Primarily, PCMs are targeted by researchers for use in different components of buildings for thermal efficiency; thus, this study aimed to provide a suitable PCM to optimize indoor thermal comfort and minimize the cooling loads of residential buildings in tropical climates through simulation of a tropical climate building and provide optimum thickness for the selected material. Microencapsulated PCM mixed with gypsum in wallboards were used to reduce the cooling load of a building located in Darwin. The cooling load of the building was calculated using Revit software. A comparison of the cooling load of the building was carried out using PCM-incorporated wallboards of thicknesses of 0 cm, 1 cm and 2 cm in Energy Plus software. The total cooling load decreased by 1.1% when the 1-centimetre-thickness was applied to the wall, whereas a 1.5% reduction was obtained when a 2-centimetre-thick PCM layer was applied. Furthermore, the reduced cooling loads due to impregnation of the PCM-based gypsum wallboard gave reduced energy consumption. Ultimately, the 2-centimetre-thickness PCM-based gypsum wallboard gave a maximum reduction in cooling load with a 7.6% reduction in total site energy and 4.76% energy saving in USD/m2/year.


  • Open Access

    Investigating the Relationship between Human Activity and the Urban Heat Island Effect in Melbourne and Four Other International Cities Impacted by COVID-19

    by Cheuk Yin Wai, Nitin Muttil, Muhammad Atiq Ur Rehman Tariq, Prudvireddy Paresi, Raphael Chukwuka Nnachi, Anne W. M. Ng

    Climate change is one of the biggest challenges of our times, even before the onset of the Coronavirus (COVID-19) pandemic. One of the main contributors to climate change is greenhouse gas (GHG) emissions, which are mostly caused by human activities such as the burning of fossil fuels. As the lockdown due to the pandemic has minimised human activity in major cities, GHG emissions have been reduced. This, in turn, is expected to lead to a reduction in the urban heat island (UHI) effect in the cities. The aim of this paper is to understand the relationship between human activity and the UHI intensity and to provide recommendations towards developing a sustainable approach to minimise the UHI effect and improve urban resilience. In this study, historical records of the monthly mean of daily maximum surface air temperatures collected from official weather stations in Melbourne, New York City, Tokyo, Dublin, and Oslo were used to estimate the UHI intensity in these cities. The results showed that factors such as global climate and geographic features could dominate the overall temperature. However, a direct relationship between COVID-19 lockdown timelines and the UHI intensity was observed, which suggests that a reduction in human activity can diminish the UHI intensity. As lockdowns due to COVID-19 are only temporary events, this study also provides recommendations to urban planners towards long-term measures to mitigate the UHI effect, which can be implemented when human activity returns to normal.