Mario Alberto Garcia Perez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mario Alberto Garcia Perez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Nelson Chávez Gallegos
Universidad Nacional del Callao
2 shared publications - Linett Angélica Velasquez Jimenez
Universidad Nacional del Callao
2 shared publications - Santiago Linder Rubiños Jimenez
Universidad Nacional del Callao
2 shared publications - Abel Carmona Arteaga
Universidad Privada del Norte
1 shared publication - Arcelia Olga Rojas Salazar
Universidad Nacional del Callao, Callao, Peru
1 shared publication - Douglas Sarango
Universidad Nacional Mayor de San Marcos
1 shared publication
Latest Publications
- Open Access
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 505-519
Control of an aquaponic system to improve the yield of gray tilapia and lettuce cultivation
Water quality assessment presents challenges, primarily the paucity of available data and ongoing system maintenance. This research develops an automated monitoring and control of water quality parameters in aquaponic systems with internet of thing (IoT) technology. Proper fish feeding management is important, which is why the fish were fed at 12:00, 16:00 and 07:00. The most significant relative error recorded during the validation of the DS18B20, PH-4502C, SEN0244, SEN0237-A, SEN0189 and DFR0300 sensors is 5.0%. The maximum standard deviation between the mentioned sensors was 1.96, and the highest coefficient of variation reached 7.24%. Before the installation of the aquaponic system, the specific growth rate (SGR) of fish was 4.89±0.17% and after implementing the automated aquaponics system, the SGR of fish increased to 6.21±0.24%. The feed conversion ratio values of the fish, both before and after the installation of the control system, were 1.98±0.14% and 1.53±0.09%, respectively. In addition, an improvement in plant growth was observed, evidenced by the difference in the values of height, number of leaves, leaf length, and weight of the plants before and after the installation of the control system, which was 7.74 cm, 5 leaves, 5.6 cm, and 41.6 g respectively.
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 505-519
Open AccessControl of an aquaponic system to improve the yield of gray tilapia and lettuce cultivation
Water quality assessment presents challenges, primarily the paucity of available data and ongoing system maintenance. This research develops an automated monitoring and control of water quality parameters in aquaponic systems with internet of thing (IoT) technology. Proper fish feeding management is important, which is why the fish were fed at 12:00, 16:00 and 07:00. The most significant relative error recorded during the validation of the DS18B20, PH-4502C, SEN0244, SEN0237-A, SEN0189 and DFR0300 sensors is 5.0%. The maximum standard deviation between the mentioned sensors was 1.96, and the highest coefficient of variation reached 7.24%. Before the installation of the aquaponic system, the specific growth rate (SGR) of fish was 4.89±0.17% and after implementing the automated aquaponics system, the SGR of fish increased to 6.21±0.24%. The feed conversion ratio values of the fish, both before and after the installation of the control system, were 1.98±0.14% and 1.53±0.09%, respectively. In addition, an improvement in plant growth was observed, evidenced by the difference in the values of height, number of leaves, leaf length, and weight of the plants before and after the installation of the control system, which was 7.74 cm, 5 leaves, 5.6 cm, and 41.6 g respectively.
- Open Access
- 1 January 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 33 (1) , 135-150
Application of remote monitoring of biosignals and geolocation with a Wearable for patients with sequelae of the coronavirus
Several patients who have overcome coronavirus disease (COVID-19) have been left with cardiovascular and pulmonary sequelae and most medical centers lack a remote monitoring system for each patient that notifies them of any complications during rehabilitation. The objective of this research was to implement a Wearable that monitors the patient's health and alerts in case of detecting any anomaly. For this reason, a Wearable was developed that displays the patient's heart rate, oxygen saturation level and body temperature on the Light Emitting Diode (LCD) and the application mobile, sending an alert and geolocation message if anomalies are detected in vital signs. The standard deviation of heart rate, temperature and oxygen saturation was obtained, which was 1.4930, 0.1558 and 0.4364 in the rest stage, respectively, and 6.3442, 0.2365 and 0.9186 in the physical activity stage respectively with a maximum duration of 42 hours and 52 minutes of battery, managing to send alert messages and store the information in the cloud, which allows to conclude that the Wearable can facilitate the management of the database and the location of the patient, that the measurement error increases with physical activity, and that battery life varies with the number of biosignal readings per hour.
- 1 January 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 33 (1) , 135-150
Open AccessApplication of remote monitoring of biosignals and geolocation with a Wearable for patients with sequelae of the coronavirus
Several patients who have overcome coronavirus disease (COVID-19) have been left with cardiovascular and pulmonary sequelae and most medical centers lack a remote monitoring system for each patient that notifies them of any complications during rehabilitation. The objective of this research was to implement a Wearable that monitors the patient's health and alerts in case of detecting any anomaly. For this reason, a Wearable was developed that displays the patient's heart rate, oxygen saturation level and body temperature on the Light Emitting Diode (LCD) and the application mobile, sending an alert and geolocation message if anomalies are detected in vital signs. The standard deviation of heart rate, temperature and oxygen saturation was obtained, which was 1.4930, 0.1558 and 0.4364 in the rest stage, respectively, and 6.3442, 0.2365 and 0.9186 in the physical activity stage respectively with a maximum duration of 42 hours and 52 minutes of battery, managing to send alert messages and store the information in the cloud, which allows to conclude that the Wearable can facilitate the management of the database and the location of the patient, that the measurement error increases with physical activity, and that battery life varies with the number of biosignal readings per hour.
- Open Access
- 16 December 2021
- Published by Universidad Nacional Mayor de San Marcos, Vicerectorado de Investigacion in Revista de Investigación de Física
- Vol. 24 (3) , 68-77
Generación de precipitaciones y caudales de máximas avenidas para las cuencas del río Biabo
Este trabajo se enfoca en el cálculo y validación de los parámetros usados para la generación de caudales de máximas avenidas a lo largo de 16 puntos de interés en el cauce principal del río Biabo. Debido a la insuficiente información de mediciones meteorológicas e hidrométricas dentro de la cuenca, se utilizó la información grillada de precipitación diaria de la base de datos PISCO v2.1 del SENAMHI, el modelo de curvas de duración frecuencia del estudio ILLA-SENAMHI-UNI, y el hidrograma unitario de Snyder, y los resultados obtenidos fueron calibrados en base a los registros de caudales máximos de la estación hidrométrica Requena-Biabo. Así, por ejemplo, para la cuenca de la estación Requena-Biabo, la comparación entre los caudales de máximas avenidas generados con los caudales registrados para diferentes tiempos de retorno, el error obtenido fluctúa entre ±5%.
- 16 December 2021
- Published by Universidad Nacional Mayor de San Marcos, Vicerectorado de Investigacion in Revista de Investigación de Física
- Vol. 24 (3) , 68-77
Open AccessGeneración de precipitaciones y caudales de máximas avenidas para las cuencas del río Biabo
Este trabajo se enfoca en el cálculo y validación de los parámetros usados para la generación de caudales de máximas avenidas a lo largo de 16 puntos de interés en el cauce principal del río Biabo. Debido a la insuficiente información de mediciones meteorológicas e hidrométricas dentro de la cuenca, se utilizó la información grillada de precipitación diaria de la base de datos PISCO v2.1 del SENAMHI, el modelo de curvas de duración frecuencia del estudio ILLA-SENAMHI-UNI, y el hidrograma unitario de Snyder, y los resultados obtenidos fueron calibrados en base a los registros de caudales máximos de la estación hidrométrica Requena-Biabo. Así, por ejemplo, para la cuenca de la estación Requena-Biabo, la comparación entre los caudales de máximas avenidas generados con los caudales registrados para diferentes tiempos de retorno, el error obtenido fluctúa entre ±5%.