SHSem Hoogteijling

Sem Hoogteijling

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sem Hoogteijling has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Interpretable metrics for evaluating fidelity, diversity, and privacy in synthetic EEG data

    by Inês Silveira, Luís Silva, Dania Furk, Beatriz Marques, Nianfei Ao, Sem Hoogteijling, Irene Heijink, Maeike Zijlmans, Hugo Gamboa

  • Open Access

    Multi-channel intraoperative ECoG synthesis through ioECoGAN

    by Inês Silveira, Sem Hoogteijling, Beatriz Marques, Nianfei Ao, Irene Heijink, Fernando Gómez-Acebo, Hui Liu, Hugo Gamboa, Maeike Zijlmans, Luís Silva

    Large-scale invasive recordings of human brain activity are rare and typically obtained only from diseased individuals, limiting systematic investigation of complex neuronal dynamics. This constraint is particularly evident in epilepsy surgery, where intraoperative electrocorticography (ioECoG) data are scarce due to limited subjects, low-density grids, and short recording durations. Synthetic data offer a potential solution; however, most existing approaches focus on single-channel EEG and evaluate quality primarily through downstream classification performance. We propose a hybrid Transformer–Generative Adversarial Network for multi-channel ioECoG synthesis that explicitly models spatio-temporal dependencies across channels and time. The architecture builds upon a Deep Convolutional Wasserstein GAN with Gradient Penalty (DCWGAN-GP) and introduces a hierarchical transformer-based critic to capture local spatio-temporal interactions and global inter-channel structure. Synthetic data quality was assessed using a structured evaluation framework encompassing fidelity, diversity, privacy, cross-channel organization, and interpretability. Results demonstrate preservation of key statistical dependencies and variability, with limitations primarily in long-range temporal dynamics and subject-specific variability. Cross-channel analyses indicate alignment in global spatial organization between real and synthetic data, albeit with reduced local specificity. Explainability analyses further reveal that the model learns structured spatial, spectral, and temporal dependencies rather than memorizing individual samples. These findings support the generation of realistic multi-channel ioECoG signals with preserved interconnectivity patterns, providing a foundation for reliable synthetic datasets to advance data-driven modeling of neurological disorders, including epileptogenic tissue identification.

  • Open Access

    Interpretable Metrics for Evaluating Fidelity, Diversity, and Privacy in Synthetic EEG Data

    by Inês Silveira, Luís Silva, Dania Furk, Beatriz Marques, Nianfei Ao, Sem Hoogteijling, Irene Heijink, Maeike Zijlmans, Hugo Gamboa

    The generation of synthetic electroencephalography (EEG) data has emerged as a promising strategy to mitigate the scarcity of real datasets in neuroscience. Medical data collection, particularly of intracranial EEG (iEEG), remains constrained by the complexity of acquisition procedures and the limited availability of eligible participants. While generative models offer a powerful means to produce realistic synthetic data, their progress is hindered by the absence of standardized evaluation protocols. Existing metrics are largely confined to basic statistical comparisons and fail to capture the intrinsic multi-domain characteristics of EEG signals such as non-stationarity, spectral complexity and fractal dynamics. To address this gap, we present a comprehensive evaluation framework that assesses synthetic (i)EEG across three complementary dimensions: fidelity, diversity, and privacy. The framework introduces novel metrics to quantify time-, frequency-, time–frequency-, and complexity-based similarities, evaluate population-level coverage and variability, and estimate identity disclosure risk. Each metric is provided with interpretation guidelines and integrated into composite scores, enabling transparent benchmarking and systematic comparison across generative models. This framework, released as the open-source Python library seege_, advances methodological rigour and interpretability, providing a comprehensive and standardized evaluation toolkit for generative models in clinical and neuroscientific applications.


  • Open Access

    Advancing intraoperative brain mapping: First-in-human evaluation of flexible high-density electrocorticography grids for epilepsy surgery

    by Sem Hoogteijling, Carmen Gelpke, Eline V. Schaft, Ziyi Wang, Tessa Souhoka, Pieter van Eijsden, Anna Diop, Karolina Janikowska, Willem M. Otte, Nicole E.C. van Klink, et al.

  • Open Access

    Spectral entropy variability of intraoperative electrocorticography predicts outcome after epilepsy surgery in people with focal cortical dysplasia

    by Eline V Schaft, Sem Hoogteijling, Dongqing Sun, Cyrille H Ferrier, Pieter van Eijsden, Wim M Otte, Galia Anguelova, Nick F Ramsey, Maryse A Van'T Klooster, Maeike Zijlmans, et al.

    Objective: Epilepsy surgery in people with focal cortical dysplasia (FCD) requires accurate removal of all epileptogenic tissue, and outcome is difficult to predict. We explored whether spectral entropy, a fast computable electroencephalographic (EEG) feature, could estimate epileptic activity in intraoperative electrocorticography (ioECoG) and forecast postsurgical outcomes. Methods: We included people with FCD pathology who underwent ioECoG‐assisted resective surgery. We analyzed ioECoG recordings acquired before and after resection. We computed spectral entropy across eight frequency bands (1–500, 1–4, 4–8, 8–12, 12–20, 20–80, 80–250, 250–500 Hz) in 2‐s epochs during 1 min, and the mean and SD per electrode. The preresection features were the input for a random forest machine learning model to classify channels covering resected from nonresected tissue. Explainable artificial intelligence was used to select features that positively influenced the model predicting resected tissue. We then related these markers measured after the resection to postsurgical outcome using trend analysis (Jonckheere–Terpstra) across outcome groups Engel IA without medication, Engel IA–D, Engel II, Engel III, and Engel IV. Results: We analyzed ioECoG data from 37 patients (age range = 0–61 years, 21 patients were ≤16 years), including 2270 preresection and 1278 postresection channels. The random forest model discriminated between resected and nonresected cortex (validation fold area under the curve = .84, 95% confidence interval =.74–.95). Features with the strongest positive Shapley Additive Explanations values included high spectral entropy variability (SEV) in the 80–500‐Hz bands. In postresection recordings, higher mean SEV and greater spatial variability of SEV were associated with poorer Engel outcome across several frequency bands. After multiple comparison correction, the positive relationship of high mean SEV ( p = .004) and high spatial variability ( p = .001) at 250–500 Hz with poor seizure outcome remained statistically significant. Significance: SEV is a real‐time computable invasive EEG marker that represents persisting epileptic activity after resection. SEV may be used to evaluate resection adequacy directly or may reflect residual epileptic activity. This would enable epilepsy surgery guidance and postsurgical counseling and decision‐making.


  • Open Access

    Rethinking Trust in Synthetic Health Data: Lessons from Seven European Research Initiatives (Preprint)

    by Jens Declerck, Dipak Kalra, Antti Airola, Ahmed Youssef Ali Amer, Christos Chatzichristos, Maria del Mar Mañu, Bruno M. de Brito Robalo, Francesco Ghini, Alberto Gutierrez-Torre, Sem Hoogteijling, et al.

    Synthetic data generation (SDG) structured health data is increasingly promoted as a solution to longstanding barriers in health data access. It is offering the promise of privacy-preserving data reuse for research, innovation, and policy. Despite rapid technical advances, the adoption of synthetic health data in real-world settings remains limited. Shaped by challenges around data quality, representativeness, infrastructure readiness, trust, and legal uncertainty, this viewpoint draws on experiences from 7 European research initiatives within the HealthData4EU cluster to reflect on how SDG is being operationalized in practice. It synthesizes cross-project insights to highlight recurring methodological and governance tensions and to examine their implications for trust and responsible use. The analysis argues that trustworthy SDG cannot be achieved through technical optimization alone but requires alignment between evaluation practices, upstream data stewardship, regulatory clarity, and sustained stakeholder engagement. Addressing these conditions is essential for moving synthetic data from experimental pilots toward a credible and sustainable component of European health research ecosystems.


  • Open Access

    Building Trust in Synthetic Health Data: Methodological and Acceptance Challenges across Seven European Projects (Preprint)

    by Jens Declerck, Dipak Kalra, Antti Airola, Ahmed Youssef Ali Amer, Christos Chatzichristos, Maria del Mar Mañu, Bruno M. de Brito Robalo, Francesco Ghini, Alberto Gutierrez-Torre, Sem Hoogteijling, et al.

    BACKGROUND Synthetic data generation (SDG) is increasingly used in health research to address privacy concerns and data sharing barriers, particularly in cross-border and multi-institutional contexts. Despite growing interest, questions remain around the methodological soundness, legal status, and real-world trustworthiness of synthetic health data. OBJECTIVE This paper examines how SDG is operationalized across seven European projects in the HealthData4EU cluster. It identifies common methodological, compliance, and acceptance challenges, and highlights emerging strategies to ensure the quality and utility of synthetic health data. METHODS A qualitative multiple case study approach was used, combining workshop presentations with structured input from each project. Projects were analyzed across four aspects: methodological challenges, data quality assurance, trust and transparency strategies, and contributions to the wider synthetic data ecosystem. RESULTS Results reveal recurring challenges across projects: tension between privacy and utility, lack of shared quality validation standards, institutional readiness gaps, and legal ambiguity under GDPR. Projects employ varied strategies, including federated machine learning and validation pipelines, differential privacy, co-design processes, and metadata transparency tools, but implementation remains uneven. The absence of harmonised legal and evaluation frameworks continues to hinder broader uptake. CONCLUSIONS To scale SDG from isolated pilots to trusted European infrastructure, four priorities are critical: shared evaluation metrics, legal clarity, sustainable platforms, and embedded stakeholder engagement. While rooted in specific projects, the insights offer broader relevance for global SDG efforts, as the core tensions identified are likely to recur across health systems.

  • Open Access

    The optimal montage to mark interictal epileptiform discharges and high-frequency oscillations in intraoperative electrocorticography

    by Ziyi Wang, Jiaojiao Guo, Eline Schaft, Sem Hoogteijling, Cyrille H. Ferrier, Gerhard H. Visser, Dongqing Sun, Friso Hoefnagels, Taku Inada, Sandra van der Salm, et al.


  • Open Access

    Super-resolution for localizing electrode grids as small, deformable objects during epilepsy surgery using augmented reality headsets

    by Hizirwan S. Salim, Abdullah Thabit, Sem Hoogteijling, Maryse A. van ’t Klooster, Theo van Walsum, Maeike Zijlmans, Mohamed Benmahdjoub

    Purpose: Epilepsy surgery is a potential curative treatment for people with focal epilepsy. Intraoperative electrocorticogram (ioECoG) recordings from the brain guide neurosurgeons during resection. Accurate localization of epileptic activity and thus the ioECoG grids is critical for successful outcomes. We aim to develop and evaluate the feasibility of a novel method for localizing small, deformable objects using augmented reality (AR) head-mounted displays (HMDs) and artificial intelligence (AI). AR HMDs combine cameras and patient overlay visualization in a compact design. Methods: We developed an image processing method for the HoloLens 2 to localize a 64-electrode ioECoG grid even when individual electrodes are indistinguishable due to low resolution. The method combines object detection, super-resolution, and pose estimation AI models with stereo triangulation. A synthetic dataset of 90,000 images trained the super-resolution and pose estimation models. The system was tested in a controlled environment against an optical tracker as ground truth. Accuracy was evaluated at distances between 40 and 90 cm. Results: The system achieved sub-5 mm accuracy in localizing the ioECoG grid at distances shorter than 60 cm. At 40 cm, the accuracy remained below 2 mm, with an average standard deviation of less than 0.5 mm. At 60 cm the method processed on average 24 stereo frames per second. Conclusion: This study demonstrates the feasibility of localizing small, deformable objects like ioECoG grids using AR HMDs. While results indicate clinically acceptable accuracy, further research is needed to validate the method in clinical environments and assess its impact on surgical precision and outcomes.

  • Open Access

    Designing for Qualitative Evaluation of Synthetic Medical Data

    by Isabella Barbosa Silva, Elsa Oliveira, Ricardo Melo, Luís Rosado, César Gálvez-Barrón, Irene Bernadet Heijink, Sem Hoogteijling, Iñigo Gabilondo