ESEline V. Schaft

Eline V. Schaft

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eline V. Schaft has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Maeike Zijlmans

    Department of Neurology and Neurosurgery University Medical Center, Utrecht Brain Center, member of European Reference Network EpiCARE Utrecht the Netherlands

    8 shared publications
  • Dongqing Sun

    Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, University Medical Center Utrecht, Utrecht, The Netherlands

    5 shared publications
  • Maryse A. van 'T Klooster

    Department of Neurology and Neurosurgery University Medical Center, Utrecht Brain Center, member of European Reference Network EpiCARE Utrecht the Netherlands

    3 shared publications
  • Sem Hoogteijling

    Department of Neurology and Neurosurgery, Brain Center, University Medical Center Utrecht, Part of ERN EpiCARE, GA Utrecht, The Netherlands

    3 shared publications
  • Cyrille H. Ferrier

    Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, University Medical Center Utrecht, Part of ERN EpiCARE, P.O. box 85500, 3508 GA Utrecht, The Netherlands

    2 shared publications
  • Geertjan Huiskamp

    Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, University Medical Center Utrecht, Part of ERN EpiCARE, P.O. box 85500, 3508 GA Utrecht, The Netherlands

    2 shared publications

Latest Publications

  • Open Access

    Spectral entropy variability of intraoperative electrocorticography predicts outcome after epilepsy surgery in people with focal cortical dysplasia

    by Eline V Schaft, Sem Hoogteijling, Dongqing Sun, Cyrille H Ferrier, Pieter van Eijsden, Wim M Otte, Galia Anguelova, Nick F Ramsey, Maryse A Van'T Klooster, Maeike Zijlmans, et al.

    Objective: Epilepsy surgery in people with focal cortical dysplasia (FCD) requires accurate removal of all epileptogenic tissue, and outcome is difficult to predict. We explored whether spectral entropy, a fast computable electroencephalographic (EEG) feature, could estimate epileptic activity in intraoperative electrocorticography (ioECoG) and forecast postsurgical outcomes. Methods: We included people with FCD pathology who underwent ioECoG‐assisted resective surgery. We analyzed ioECoG recordings acquired before and after resection. We computed spectral entropy across eight frequency bands (1–500, 1–4, 4–8, 8–12, 12–20, 20–80, 80–250, 250–500 Hz) in 2‐s epochs during 1 min, and the mean and SD per electrode. The preresection features were the input for a random forest machine learning model to classify channels covering resected from nonresected tissue. Explainable artificial intelligence was used to select features that positively influenced the model predicting resected tissue. We then related these markers measured after the resection to postsurgical outcome using trend analysis (Jonckheere–Terpstra) across outcome groups Engel IA without medication, Engel IA–D, Engel II, Engel III, and Engel IV. Results: We analyzed ioECoG data from 37 patients (age range = 0–61 years, 21 patients were ≤16 years), including 2270 preresection and 1278 postresection channels. The random forest model discriminated between resected and nonresected cortex (validation fold area under the curve = .84, 95% confidence interval =.74–.95). Features with the strongest positive Shapley Additive Explanations values included high spectral entropy variability (SEV) in the 80–500‐Hz bands. In postresection recordings, higher mean SEV and greater spatial variability of SEV were associated with poorer Engel outcome across several frequency bands. After multiple comparison correction, the positive relationship of high mean SEV ( p = .004) and high spatial variability ( p = .001) at 250–500 Hz with poor seizure outcome remained statistically significant. Significance: SEV is a real‐time computable invasive EEG marker that represents persisting epileptic activity after resection. SEV may be used to evaluate resection adequacy directly or may reflect residual epileptic activity. This would enable epilepsy surgery guidance and postsurgical counseling and decision‐making.


  • Open Access

    Multi-montage visualization of interictal epileptic events in high-density intraoperative electrocorticography

    by Jiaojiao Guo, Ziyi Wang, Nicole van Klink, Eline Schaft, Dongqing Sun, Sandra van der Salm, Maryse van ’T Klooster, Maeike Zijlmans


  • Open Access

    The optimal montage to mark interictal epileptiform discharges and high-frequency oscillations in intraoperative electrocorticography

    by Ziyi Wang, Jiaojiao Guo, Eline Schaft, Sem Hoogteijling, Cyrille H. Ferrier, Gerhard H. Visser, Dongqing Sun, Friso Hoefnagels, Taku Inada, Sandra van der Salm, et al.


  • Open Access

    Implementing intraoperative high‐density electrocorticography during epilepsy surgery

    by Eline V. Schaft, Dongqing Sun, Sem Hoogteijling, Ziyi Wang, Frans S. S. Leijten, Pieter van Eijsden, Nick F. Ramsey, Pierre Robe, Maryse A. van 'T Klooster, Maeike Zijlmans

    Objective: In intraoperative electrocorticography (ioECoG)–tailored epilepsy surgery, standard low‐density (LD) electrode grids (16–20 electrodes, 10 mm inter‐electrode distance) are used, covering ±20 cm 2 of cortex. High‐density (HD) grids have shown advantages in basic research. We wanted to evaluate the clinical use of HD grids during epilepsy surgery. We assessed how often HD‐ioECoG might have altered the presurgical hypothesis by recording highly localized epileptic spikes and high‐frequency oscillations (HFOs) and by facilitating spike‐onset localization. Methods: Patients undergoing HD‐ioECoG–tailored epilepsy surgery (64 electrodes, 5 mm inter‐electrode distance; 2048 Hz sampling) were selected from our registry (2021–2023). We assessed clinical reports to evaluate the impact on surgical strategy. Intraoperative decision‐making was guided mainly by interictal spikes. We visually marked spikes and HFOs (ripples 80–250 Hz and fast ripples [FRs] 250–500 Hz) in 1‐min artifact‐free epochs. We assessed number of events, and compared channels covering the resected and non‐resected tissue and surgical outcome with logistic mixed models. We assessed focal events, which occurred in few channels and could be missed on LD grids. We analyzed spike‐onset localization with Granger's causality. Results: We included 36 HD grid positions from 20 patients. HD‐ioECoG would have confirmed the original surgical plans in 11 patients and adapted it in 6. We found 41–5485 spikes, 0–2243 ripples (one patient none), and 0–1008 FR (three patients none) per patient. More FRs occurred in channels covering the resected areas than outside ( p < .001), particularly in patients who became seizure‐free ( p < .001). Of the spikes, ripples, and FRs, 6.1%, 19.5%, and 46.7%, respectively, occurred on one or two channels; 58.3% of the HD spike‐onset locations might be localized differently with standard LD grids. Significance: HD‐ioECoG can be used clinically for epilepsy surgery guidance. HD‐ioECoG captured increased detail when identifying focal epileptic events, especially FRs, and pinpointing spike onsets, which may be missed with LD‐ioECoG.


  • Open Access

    Robust compression and detection of epileptiform patterns in ECoG using a real-time spiking neural network hardware framework

    by Filippo Costa, Eline V. Schaft, Geertjan Huiskamp, Erik J. Aarnoutse, Maryse A. Van’t Klooster, Niklaus Krayenbühl, Georgia Ramantani, Maeike Zijlmans, Giacomo Indiveri, Johannes Sarnthein

    Interictal Epileptiform Discharges (IED) and High Frequency Oscillations (HFO) in intraoperative electrocorticography (ECoG) may guide the surgeon by delineating the epileptogenic zone. We designed a modular spiking neural network (SNN) in a mixed-signal neuromorphic device to process the ECoG in real-time. We exploit the variability of the inhomogeneous silicon neurons to achieve efficient sparse and decorrelated temporal signal encoding. We interface the full-custom SNN device to the BCI2000 real-time framework and configure the setup to detect HFO and IED co-occurring with HFO (IED-HFO). We validate the setup on pre-recorded data and obtain HFO rates that are concordant with a previously validated offline algorithm (Spearman’s ρ = 0.75, p = 1e-4), achieving the same postsurgical seizure freedom predictions for all patients. In a remote on-line analysis, intraoperative ECoG recorded in Utrecht was compressed and transferred to Zurich for SNN processing and successful IED-HFO detection in real-time. These results further demonstrate how automated remote real-time detection may enable the use of HFO in clinical practice.


  • Open Access

    Spatial and temporal properties of intra-operatively recorded spikes and high frequency oscillations in focal cortical dysplasia

    by Eline V. Schaft, Dongqing Sun, Maryse A. van 'T Klooster, Dorien van Blooijs, Paul L. Smits, Willemiek J.E.M. Zweiphenning, Peter H. Gosselaar, Cyrille H. Ferrier, Maeike Zijlmans


  • Open Access

    Intraoperative mapping of epileptogenic foci and tumor infiltration in neuro-oncology patients with epilepsy

    by Dongqing Sun, Eline V Schaft, Bibi M van Stempvoort, Tineke A Gebbink, Maryse van ‘t Klooster, Pieter van Eijsden, Sandra M A van der Salm, Jan Willem Dankbaar, Maeike Zijlmans, Pierre A Robe

    Epileptogenesis and glioma growth have a bidirectional relationship. We hypothesized people with gliomas can benefit from the removal of epileptic tissue and that tumor-related epileptic activity may signify tumor infiltration in peritumoral regions. We investigated whether intraoperative electrocorticography (ioECoG) could improve seizure outcomes in oncological glioma surgery, and vice versa, what epileptic activity (EA) tells about tumor infiltration. We prospectively included patients who underwent (awake) ioECoG-assisted diffuse-glioma resection through the oncological trajectory. The IoECoG-tailoring strategy relied on ictal and interictal EA (spikes and sharp waves). Brain tissue, where EA was recorded, was assigned for histopathological examination separate from the rest of the tumor. Weibull regression was performed to assess how residual EA and extent of resection (EOR) related to the time-to-seizure recurrence, and we investigated which type of EA predicted tumor infiltration. Fifty-two patients were included. Residual spikes after resection were associated with seizure recurrence in patients with isocitrate dehydrogenase (IDH) mutant astrocytoma or oligodendroglioma (HR = 7.6[1.4–40.0], P-value = .01), independent from the EOR. This was not observed in IDH-wildtype tumors. All tissue samples resected based on interictal spikes were infiltrated by tumor, even if the MRI did not show abnormalities. Complete resection of epileptogenic foci in ioECoG may promote seizure control in IDH-mutant gliomas. The cohort size of IDH-wildtype tumors was too limited to draw definitive conclusions. Interictal spikes may indicate tumor infiltration even when this area appears normal on MRI. Integrating electrophysiology guidance into oncological tumor surgery could contribute to improved seizure outcomes and precise guidance for radical tumor resection.


  • Open Access

    Signaalkarakteristieken in mensen met een focale corticale dysplasie

    by Eline Schaft, Maryse Van 'T Klooster, Maeike Zijlmans

    Het elektrocorticogram wordt toegepast als hulpmiddel bij de afgrenzing tussen epileptogeen weefsel en gezondweefsel tijdens epilepsiechirurgie. Mensen met een focale corticale dysplasie die intra-operatieve elektrocorticografieondergaan hebben vaak een kenmerkend elektrocorticogram. In deze studie worden de lokaliserende en tijd-gerela-teerde eigenschappen van met het elektrocorticogram gemeten pieken en hoogfrequente oscillaties geanalyseerd.