Valeriy Konshin
Research Subjects
Valeriy Konshin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Sergey I. Kosenko
Department of Nuclear Power Plants of the Educational and Scientific Institute of Energy of the National University "Odesa Polytechnic
3 shared publications - Vadym Kondratyuk
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», просп. Берестейський, 37, Київ, 03056, Україна
3 shared publications - Volodymyr I. Skalozubov
Міжвідомчий центр фундаментальних наукових досліджень в галузі енергетики та екології НАН України, «Одеської політехніки» та Мінекології України
3 shared publications - Andriy Ostapovets
Акціонерне товариство «Національна енергогенеруюча компанія «Енергоатом», м. Київ, Україна
1 shared publication - Anna Aniushkina1 shared publication
- Bohdan Hodunok1 shared publication
Latest Publications
- Open Access
- 31 October 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
ASSESSMENT OF THE IMPACT OF DIFFERENT CORE LAYOUT ON THE RADIATION LOAD OF VVER-1000 REACTOR INTERNAL DEVICES
When operating the power units of nuclear power plants beyond their projected lifespan, it is crucial to consider the impact of various operational factors, such as neutron irradiation, elevated temperatures, and cyclic loading, on the reactor core and internal structures. These factors lead to significant changes in the properties of the metal used in these components. It is also important to note that each change in reactor power results in a considerable variation in gamma radiation, which, in turn, contributes to the cyclic loading of the core baffle and the reactor barrel. This effect is primarily manifested in the reduced resistance to brittle fracture, commonly referred to as embrittlement, and it also leads to an increase in radiation exposure for the reactor core and internal devices. The implementation of core layouts that minimize neutron leakage from the active zone is one of the key measures to reduce the radiation impact on the discussed elements of internal structures. This is achieved by strategically placing spent fuel assemblies still in operation at the periphery of the active zone and fresh fuel in the central region. Different configurations of fuel loadings in nuclear reactors significantly influence the unevenness of energy release, which can introduce additional safety risks. In this article, various configurations of the reactor's active zone have been examined using thermal power assemblies of the types TVSA and FA-WR. Additionally, a comparison was made regarding the influence of these assemblies on the radiation exposure of the shielding structures under the considered fuel loading configurations. As a result of the calculations performed, values for the fast neutron flux were obtained at selected calculation points within the active zone of the VVER-1000 reactor and at the center of the internal core shaft. Furthermore, the distribution of power outputs from the core baffle in the axial layer of maximum loading was also determined.
- 31 October 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
Open AccessASSESSMENT OF THE IMPACT OF DIFFERENT CORE LAYOUT ON THE RADIATION LOAD OF VVER-1000 REACTOR INTERNAL DEVICES
When operating the power units of nuclear power plants beyond their projected lifespan, it is crucial to consider the impact of various operational factors, such as neutron irradiation, elevated temperatures, and cyclic loading, on the reactor core and internal structures. These factors lead to significant changes in the properties of the metal used in these components. It is also important to note that each change in reactor power results in a considerable variation in gamma radiation, which, in turn, contributes to the cyclic loading of the core baffle and the reactor barrel. This effect is primarily manifested in the reduced resistance to brittle fracture, commonly referred to as embrittlement, and it also leads to an increase in radiation exposure for the reactor core and internal devices. The implementation of core layouts that minimize neutron leakage from the active zone is one of the key measures to reduce the radiation impact on the discussed elements of internal structures. This is achieved by strategically placing spent fuel assemblies still in operation at the periphery of the active zone and fresh fuel in the central region. Different configurations of fuel loadings in nuclear reactors significantly influence the unevenness of energy release, which can introduce additional safety risks. In this article, various configurations of the reactor's active zone have been examined using thermal power assemblies of the types TVSA and FA-WR. Additionally, a comparison was made regarding the influence of these assemblies on the radiation exposure of the shielding structures under the considered fuel loading configurations. As a result of the calculations performed, values for the fast neutron flux were obtained at selected calculation points within the active zone of the VVER-1000 reactor and at the center of the internal core shaft. Furthermore, the distribution of power outputs from the core baffle in the axial layer of maximum loading was also determined.
- Open Access
- 28 December 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Innovation researches in students’ scientific work
- No. 2 (1368),p. 47-52
CRITERION-BASED METHOD FOR QUALIFYING THE STRATEGY OF INCREASING THE NOMINAL POWER OF NUCLEAR REACTORS
In the materials of the article, examples the analysis of known approaches to the substantiation (qualification) of strategies for operating VVER/PWR nuclear reactors at increased nominal power levels is presented. It has been established that the main shortcomings of the existing approaches to qualifying upgrades of the nuclear reactor core lie in the dependence of qualification results on the implementation methods of the reactor operation strategy in high nominal power modes, as well as on the effects of differences in deterministic codes and/or user expertise with such codes. These factors ultimately complicate the objective interpretation of qualification results. A criterion-based method for qualifying the strategy for operating nuclear reactors at increased nominal power levels has been developed. This method is based on upgrading the thermophysical properties of nuclear fuel and the design and technical parameters of fuel element components. It eliminates the influence of variations in deterministic codes and/or user expertise with such codes and considers safety assurance conditions under the maximum allowable temperatures for fuel cladding and nuclear fuel.
- 28 December 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Innovation researches in students’ scientific work
- No. 2 (1368),p. 47-52
Open AccessCRITERION-BASED METHOD FOR QUALIFYING THE STRATEGY OF INCREASING THE NOMINAL POWER OF NUCLEAR REACTORS
In the materials of the article, examples the analysis of known approaches to the substantiation (qualification) of strategies for operating VVER/PWR nuclear reactors at increased nominal power levels is presented. It has been established that the main shortcomings of the existing approaches to qualifying upgrades of the nuclear reactor core lie in the dependence of qualification results on the implementation methods of the reactor operation strategy in high nominal power modes, as well as on the effects of differences in deterministic codes and/or user expertise with such codes. These factors ultimately complicate the objective interpretation of qualification results. A criterion-based method for qualifying the strategy for operating nuclear reactors at increased nominal power levels has been developed. This method is based on upgrading the thermophysical properties of nuclear fuel and the design and technical parameters of fuel element components. It eliminates the influence of variations in deterministic codes and/or user expertise with such codes and considers safety assurance conditions under the maximum allowable temperatures for fuel cladding and nuclear fuel.
- 17 December 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 4
REACTOR NOZZLES AREA BIOLOGICAL SHIELDING ASSESSMENT OF THE ZNPP UNIT 5 FOR THE PURPOSE OF EXTENDING SERVICE LIFE
Extension of the service life of nuclear power plants in Ukraine beyond the design life, as in most countries operating nuclear power units, is an accepted strategy and is being implemented in practice. In this regard, verification calculations are needed to determine the service life of the main elements of power equipment. The paper is devoted to determining the causes and mechanisms of the ageing of the biological protection elements of the spigot zone and developing measures to manage the ageing of the biological protection of the spigot zone. An attempt was made to develop a calculation justification for the residual life of the biological protection of the spigot zone, based on which it is possible to conclude that the life of the biological protection can be extended. The work was carried out by adapting the results of the reporting documentation related to determining the effectiveness and reassignment of the service life of biological protection of ZNPP Units 1-4. The technical condition of the biological protection elements was assessed based on the data of gamma radiation effective dose rate (EDR) based on measurements on standard stationary dose rate sensors in the GA701 room for a ten-year period of operation. The method of ‘relaxation lengths’ was used to determine the group of technical condition parameters that determine protection against neutron radiation in the area of the spigots. Recursive analysis of changes in the radiation situation at ZNPP Unit 5 was performed to assess the degree of degradation of biological protection elements during the operating period, which allowed to assess the regularities of the radiation situation development at the unit and to predict changes in the parameters of the BP for short- and long-term periods. The results of the technical condition assessment allow us to recommend extending the lifetime of Zaporizhzhia NPP Unit 5 (in terms of compliance with the biological protection of the spigot area of the reactor) for an over-design period of up to 50 years.
- 17 December 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 4
REACTOR NOZZLES AREA BIOLOGICAL SHIELDING ASSESSMENT OF THE ZNPP UNIT 5 FOR THE PURPOSE OF EXTENDING SERVICE LIFE
Extension of the service life of nuclear power plants in Ukraine beyond the design life, as in most countries operating nuclear power units, is an accepted strategy and is being implemented in practice. In this regard, verification calculations are needed to determine the service life of the main elements of power equipment. The paper is devoted to determining the causes and mechanisms of the ageing of the biological protection elements of the spigot zone and developing measures to manage the ageing of the biological protection of the spigot zone. An attempt was made to develop a calculation justification for the residual life of the biological protection of the spigot zone, based on which it is possible to conclude that the life of the biological protection can be extended. The work was carried out by adapting the results of the reporting documentation related to determining the effectiveness and reassignment of the service life of biological protection of ZNPP Units 1-4. The technical condition of the biological protection elements was assessed based on the data of gamma radiation effective dose rate (EDR) based on measurements on standard stationary dose rate sensors in the GA701 room for a ten-year period of operation. The method of ‘relaxation lengths’ was used to determine the group of technical condition parameters that determine protection against neutron radiation in the area of the spigots. Recursive analysis of changes in the radiation situation at ZNPP Unit 5 was performed to assess the degree of degradation of biological protection elements during the operating period, which allowed to assess the regularities of the radiation situation development at the unit and to predict changes in the parameters of the BP for short- and long-term periods. The results of the technical condition assessment allow us to recommend extending the lifetime of Zaporizhzhia NPP Unit 5 (in terms of compliance with the biological protection of the spigot area of the reactor) for an over-design period of up to 50 years.
- 10 December 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
SPECIFIC OF THERMOHYDRAULIC CALCULATIONS OF CORE PRESSURIZED WATER SMALL MODULAR REACTORS IN CASE NATURAL CIRCULATION OF THE COOLANT
The article has been devoted to the study of the main features of pressurized water small modular reactors and an analysis of the influence of the specified features on the thermohydraulic calculation of the core. Special attention is given to small modular reactors with natural circulation of the coolant. It was determined that in the calculation of the core, natural circulation affects the determination of pressure losses and the heat transfer coefficient. When determining pressure losses, the difference between natural and forced coolant circulation lies in the components of pressure losses that need to be considered. In the determination of the heat transfer coefficient, the key factor is the determination of the Nusselt number, where the circulation flow regime affects determining criteria. The issue of determining the critical heat flow using the CHF LOOK UP TABLET method is also considered for the further determination of the departure from nuclear boiling, which serves to assess the safety of operation of the installation. As an example, during the study, a thermohydraulic calculation of the core of the small modular reactor Holtec SMR-160, as one of the advanced representatives of this type of reactor, was performed. As a result of the conducted calculation, the value of pressure losses, the distribution of the heat transfer coefficient and the minimum departure from nuclear boiling were obtained. The study shows the departure from nuclear boiling obtained as a result of the calculation is close to the minimum allowable value, but it is quite acceptable considering the characteristics of natural coolant circulation. However, it necessitates further analysis during the assessment of the reactor facility's safety.
- 10 December 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 3
SPECIFIC OF THERMOHYDRAULIC CALCULATIONS OF CORE PRESSURIZED WATER SMALL MODULAR REACTORS IN CASE NATURAL CIRCULATION OF THE COOLANT
The article has been devoted to the study of the main features of pressurized water small modular reactors and an analysis of the influence of the specified features on the thermohydraulic calculation of the core. Special attention is given to small modular reactors with natural circulation of the coolant. It was determined that in the calculation of the core, natural circulation affects the determination of pressure losses and the heat transfer coefficient. When determining pressure losses, the difference between natural and forced coolant circulation lies in the components of pressure losses that need to be considered. In the determination of the heat transfer coefficient, the key factor is the determination of the Nusselt number, where the circulation flow regime affects determining criteria. The issue of determining the critical heat flow using the CHF LOOK UP TABLET method is also considered for the further determination of the departure from nuclear boiling, which serves to assess the safety of operation of the installation. As an example, during the study, a thermohydraulic calculation of the core of the small modular reactor Holtec SMR-160, as one of the advanced representatives of this type of reactor, was performed. As a result of the conducted calculation, the value of pressure losses, the distribution of the heat transfer coefficient and the minimum departure from nuclear boiling were obtained. The study shows the departure from nuclear boiling obtained as a result of the calculation is close to the minimum allowable value, but it is quite acceptable considering the characteristics of natural coolant circulation. However, it necessitates further analysis during the assessment of the reactor facility's safety.
- Open Access
- 14 June 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 2
THE FUTURE OF ATOMIС ENERGY IN UKRAINE FROM THE POSITION OF THE DEVELOPMENT OF A LOW-СARBON EСONOMY
This article studies the future development of the energy industry with the aim of reducing greenhouse gas emissions. Three different options for planning the use of electricity-generating enterprises and determining the most optimal for the environment and economy of the country based on graphs of the dynamics of greenhouse gas emissions into the atmosphere are considered. The assessment and selection of the most optimal option is based on the Low-Carbon Development Strategy of Ukraine. The types of electricity generation that most pollute the environment and those that practically do not pollute have been determined. The share of produced electricity accounted for by each type of generation and the dynamics of electricity production in recent years were considered in percentage terms. Also, this article provides an example of one of the countries abandoning nuclear energy, and what consequences this had for the energy balance and the development of a low-carbon economy. The most appropriate option for the development of power plants in Ukraine was determined and it was considered how in the future it is possible to increase the share of electricity produced at nuclear power plants and reduce the share of electricity produced at thermal power plants. The development of nuclear energy has a positive effect on the country's energy independence, so it must be developed and, if possible, switched to new types of reactors in order to make energy even more secure.
- 14 June 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 2
Open AccessTHE FUTURE OF ATOMIС ENERGY IN UKRAINE FROM THE POSITION OF THE DEVELOPMENT OF A LOW-СARBON EСONOMY
This article studies the future development of the energy industry with the aim of reducing greenhouse gas emissions. Three different options for planning the use of electricity-generating enterprises and determining the most optimal for the environment and economy of the country based on graphs of the dynamics of greenhouse gas emissions into the atmosphere are considered. The assessment and selection of the most optimal option is based on the Low-Carbon Development Strategy of Ukraine. The types of electricity generation that most pollute the environment and those that practically do not pollute have been determined. The share of produced electricity accounted for by each type of generation and the dynamics of electricity production in recent years were considered in percentage terms. Also, this article provides an example of one of the countries abandoning nuclear energy, and what consequences this had for the energy balance and the development of a low-carbon economy. The most appropriate option for the development of power plants in Ukraine was determined and it was considered how in the future it is possible to increase the share of electricity produced at nuclear power plants and reduce the share of electricity produced at thermal power plants. The development of nuclear energy has a positive effect on the country's energy independence, so it must be developed and, if possible, switched to new types of reactors in order to make energy even more secure.
- Open Access
- 11 June 2023
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 49 (2) , 95-102
APPROACHES TO MODELING CONDITIONS OF THERMOACOUSTIC INSTABILITY IN NON-EQUILIBRIUM TWO-PHASE COOLANT OF NUCLEAR REACTORS
The consequences of thermoacoustic instability of the coolant in the active zone of nuclear reactors can be high-amplitude, high-frequency dynamic loads on the internal structures and a violation of the tightness of the TVEL shells. However, until now, there are no reactor control/diagnostic systems and operational instructions for managing accidents in conditions of thermoacoustic instability of the coolant in the reactor core. The main reason for this situation is the lack of substantiated methods for modeling the criteria and conditions for the occurrence of thermoacoustic instability in the active zone. The purpose of the work is the development of a criterion method for modeling the conditions of thermoacoustic instability of the coolant in the active zone of the reactor to substantiate the appropriate reactor control systems and symptom-oriented emergency instructions. An original method of determining the criteria and conditions of thermoacoustic instability of the coolant in the active zone depending on the determining parameters of the thermodynamic state of the reactor plant has been developed.. Based on the thermodynamic approach, which takes into account the level of completion of interphase heat and mass transfer processes in acoustic pressure waves, the criteria and area of thermoacoustic instability of the coolant in the reactor core are determined. The established area of thermoacoustic instability of the coolant in the reactor core was verified on the basis of known experimental data obtained at the experimental installation, which meets the criteria of thermodynamic similarity to the core of the VVER-1000 core. Based on the developed criterion method, the main provisions and requirements for the relevant reactor control/diagnostic systems and symptom-oriented instructions for managing accidents in conditions of thermoacoustic instability of the coolant in the active zone of the reactors are defined.
- 11 June 2023
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 49 (2) , 95-102
Open AccessAPPROACHES TO MODELING CONDITIONS OF THERMOACOUSTIC INSTABILITY IN NON-EQUILIBRIUM TWO-PHASE COOLANT OF NUCLEAR REACTORS
The consequences of thermoacoustic instability of the coolant in the active zone of nuclear reactors can be high-amplitude, high-frequency dynamic loads on the internal structures and a violation of the tightness of the TVEL shells. However, until now, there are no reactor control/diagnostic systems and operational instructions for managing accidents in conditions of thermoacoustic instability of the coolant in the reactor core. The main reason for this situation is the lack of substantiated methods for modeling the criteria and conditions for the occurrence of thermoacoustic instability in the active zone. The purpose of the work is the development of a criterion method for modeling the conditions of thermoacoustic instability of the coolant in the active zone of the reactor to substantiate the appropriate reactor control systems and symptom-oriented emergency instructions. An original method of determining the criteria and conditions of thermoacoustic instability of the coolant in the active zone depending on the determining parameters of the thermodynamic state of the reactor plant has been developed.. Based on the thermodynamic approach, which takes into account the level of completion of interphase heat and mass transfer processes in acoustic pressure waves, the criteria and area of thermoacoustic instability of the coolant in the reactor core are determined. The established area of thermoacoustic instability of the coolant in the reactor core was verified on the basis of known experimental data obtained at the experimental installation, which meets the criteria of thermodynamic similarity to the core of the VVER-1000 core. Based on the developed criterion method, the main provisions and requirements for the relevant reactor control/diagnostic systems and symptom-oriented instructions for managing accidents in conditions of thermoacoustic instability of the coolant in the active zone of the reactors are defined.
- Open Access
- 19 April 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
METHOD OF QUALIFICATION OF PASSIVE SAFETY SYSTEMS OF MODULAR NUCLEAR REACTORS WITH CIRCULATION CIRCUIT FLOWS
Low-power modular reactors are a promising direction for increasing the safety of nuclear power, because accident management in modular reactors is carried out only by passive safety systems (without electric pumps). Critical for the safety of modular reactors are accidents with a violation of the tightness of the natural circulation circuits of passive safety systems. The main limitations of using traditional accident modeling approaches with deterministic codes to qualify the reliability and operability of passive safety systems of modular reactors are related to the possibility of negative effects of "code differences" and "code user differences", as well as the unfoundedness of code verification/validation results. An original qualification method has been developed to ensure the safety conditions of the passive safety systems of the Westinghouse low-power modular reactor (SMR) in the event of accidents with a violation of the tightness of the natural circulation circuits. The assumptions adopted in the developed method ensure the conservatism of qualification results. Based on the preliminary calculation qualification of the natural circulation circuits of the SMR passive safety systems, it was established that for the relative sizes of the leaks, greater than 5% of the pipeline cross-section, a violation of safety conditions and drainage of the active zone may occur less than 24 hours after the start of the accident. It is necessary to modernize the SMR with regard to systems for diagnosing leaks in natural circulation circuits of passive safety systems and isolating damaged sections of circuits.
- 19 April 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
Open AccessMETHOD OF QUALIFICATION OF PASSIVE SAFETY SYSTEMS OF MODULAR NUCLEAR REACTORS WITH CIRCULATION CIRCUIT FLOWS
Low-power modular reactors are a promising direction for increasing the safety of nuclear power, because accident management in modular reactors is carried out only by passive safety systems (without electric pumps). Critical for the safety of modular reactors are accidents with a violation of the tightness of the natural circulation circuits of passive safety systems. The main limitations of using traditional accident modeling approaches with deterministic codes to qualify the reliability and operability of passive safety systems of modular reactors are related to the possibility of negative effects of "code differences" and "code user differences", as well as the unfoundedness of code verification/validation results. An original qualification method has been developed to ensure the safety conditions of the passive safety systems of the Westinghouse low-power modular reactor (SMR) in the event of accidents with a violation of the tightness of the natural circulation circuits. The assumptions adopted in the developed method ensure the conservatism of qualification results. Based on the preliminary calculation qualification of the natural circulation circuits of the SMR passive safety systems, it was established that for the relative sizes of the leaks, greater than 5% of the pipeline cross-section, a violation of safety conditions and drainage of the active zone may occur less than 24 hours after the start of the accident. It is necessary to modernize the SMR with regard to systems for diagnosing leaks in natural circulation circuits of passive safety systems and isolating damaged sections of circuits.
- Open Access
- 8 February 2023
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 45 (1) , 91-96
APPROACHES TO MODELING CONDITIONS OF THERMOACOUSTIC INSTABILITY IN NON-EQUILIBRIUM TWO-PHASE COOLANT OF NUCLEAR REACTORS
The occurrence of thermoacoustic instability in the non-equilibrium two-phase flow of the coolant can significantly affect the reliability and integrity of the nuclear reactor's internal devices. At present, the development of adequate and justified methods for modeling thermoacoustic instability in the active zone of a nuclear reactor is an urgent issue. The purpose of the study is to develop a criterion method for determining the conditions for the occurrence of TAN in the active zone of nuclear reactors, which will increase operational safety and provide an opportunity to develop an operational system for diagnosing the conditions of TAN in the active zone of high-power reactor installations. For the conditions of transient and emergency modes of nuclear power plants with VVER, the thermodynamic approach of determining the conditions for the occurrence of thermoacoustic instability of a non-equilibrium two-phase coolant is more justified. Based on the thermodynamic approach, the conditions of thermoacoustic instability of the coolant in the active zone of the reactor were obtained. They depend on the defining thermodynamic parameters – reactor power, coolant consumption, pressure and temperature of the coolant at the entrance and exit of the active zone. It was established that in the nominal operating mode of the reactor, the coolant is stable with respect to thermoacoustic fluctuations. Based on the analysis of the well-known resonance approach to modeling the conditions for the occurrence of thermoacoustic instability (on the example of a single condensing bubble), it was established that the resonance effects of the coincidence of the frequency of propagation of acoustic waves and the frequency of condensation of steam bubbles can be significant for relatively short channels (less than 1 m) at relatively low pressures. For the conditions of transient and emergency modes of nuclear power plants with VVER, the thermodynamic approach of determining the conditions for the occurrence of thermoacoustic instability of a non-equilibrium two-phase coolant, based on the regularities of the conditions for the occurrence of oscillatory processes during acoustic perturbations of the thermodynamic parameters of the coolant flow in the active zone of a nuclear reactor, is more justified.
- 8 February 2023
- Published by Institute of Engineering Thermophysics of NAS of Ukraine in Thermophysics and Thermal Power Engineering
- Vol. 45 (1) , 91-96
Open AccessAPPROACHES TO MODELING CONDITIONS OF THERMOACOUSTIC INSTABILITY IN NON-EQUILIBRIUM TWO-PHASE COOLANT OF NUCLEAR REACTORS
The occurrence of thermoacoustic instability in the non-equilibrium two-phase flow of the coolant can significantly affect the reliability and integrity of the nuclear reactor's internal devices. At present, the development of adequate and justified methods for modeling thermoacoustic instability in the active zone of a nuclear reactor is an urgent issue. The purpose of the study is to develop a criterion method for determining the conditions for the occurrence of TAN in the active zone of nuclear reactors, which will increase operational safety and provide an opportunity to develop an operational system for diagnosing the conditions of TAN in the active zone of high-power reactor installations. For the conditions of transient and emergency modes of nuclear power plants with VVER, the thermodynamic approach of determining the conditions for the occurrence of thermoacoustic instability of a non-equilibrium two-phase coolant is more justified. Based on the thermodynamic approach, the conditions of thermoacoustic instability of the coolant in the active zone of the reactor were obtained. They depend on the defining thermodynamic parameters – reactor power, coolant consumption, pressure and temperature of the coolant at the entrance and exit of the active zone. It was established that in the nominal operating mode of the reactor, the coolant is stable with respect to thermoacoustic fluctuations. Based on the analysis of the well-known resonance approach to modeling the conditions for the occurrence of thermoacoustic instability (on the example of a single condensing bubble), it was established that the resonance effects of the coincidence of the frequency of propagation of acoustic waves and the frequency of condensation of steam bubbles can be significant for relatively short channels (less than 1 m) at relatively low pressures. For the conditions of transient and emergency modes of nuclear power plants with VVER, the thermodynamic approach of determining the conditions for the occurrence of thermoacoustic instability of a non-equilibrium two-phase coolant, based on the regularities of the conditions for the occurrence of oscillatory processes during acoustic perturbations of the thermodynamic parameters of the coolant flow in the active zone of a nuclear reactor, is more justified.
- Open Access
- 20 December 2022
- Published by The Gas Institute of the National Academy of Sciences of Ukraine in Energy Technologies & Resource Saving
- No. 4,p. 35-44
THERMOPHYSICAL PROPERTIES OF MULTICOMPONENT OZONE-SAFE REFRIGERANTS
The paper presents the results of the analysis of the use of multi-component working bodies in throttle cooling systems of an open or closed cycle using the Joule-Thompson effect (cryocoolers). The use of multicomponent refrigerants makes it possible to obtain the required thermodynamic efficiency of the cooling cycle at low throttling pressure values of 1.5...2.0 MPa. This effect becomes possible due to the introduction of components with a higher boiling point into the composition of the working fluid. In order to obtain higher operational characteristics, irreversible losses in J-T cryocoolers must be analyzed and ways of their reduction determined. The thermodynamic analysis of the installation cycle and subsequent design of the heat exchange equipment of cryocoolers formulates the conclusion that in order to optimize the design of the heat exchange equipment of the installation, which consists in solving hydrodynamic and thermal problems, a careful determination of the thermophysical properties of mixed working bodies is necessary. It should be taken into account that the principle of additivity is not always possible to apply for different compositions. By choosing certain components of the working body and changing their mass composition, it is possible to obtain the necessary properties. On the basis of experimental studies conducted at Ltd «DNIPRO MTV», the main components of the refrigerant were determined. When using mixed refrigerants, their thermophysical and calorific properties are determined taking into account the polarity of the molecules and the mass amount of the components of the mixture. Methods for determining thermophysical properties were analyzed, proposed by generalizing dependencies for determining the caloric properties of mixed refrigerants. the main components of the refrigerant are determined, namely: methane CH4, ethylene С2Н4, propane С3Н8 and isobutane С4Н10. The peculiarity of these substances is that they belong to hydrocarbons of the alkane series and are characterized by different values of thermophysical parameters. When calculating the parameters of the throttling and heat exchange processes, it is necessary to determine not only the integral characteristics, but also their values at certain parameters at the characteristic points of the process on the cycle diagram. Therefore, there is a need for obtained generalized dependencies both for individual components and for the mixture as a whole. With a significant number of options for parameters and components of the mixture, when determining the thermophysical properties of refrigerants, it is advisable to use empirical dependencies, where the values of the coefficients are obtained by processing experimental data. Bibl. 15, Fig. 1, Tab. 1.
- 20 December 2022
- Published by The Gas Institute of the National Academy of Sciences of Ukraine in Energy Technologies & Resource Saving
- No. 4,p. 35-44
Open AccessTHERMOPHYSICAL PROPERTIES OF MULTICOMPONENT OZONE-SAFE REFRIGERANTS
The paper presents the results of the analysis of the use of multi-component working bodies in throttle cooling systems of an open or closed cycle using the Joule-Thompson effect (cryocoolers). The use of multicomponent refrigerants makes it possible to obtain the required thermodynamic efficiency of the cooling cycle at low throttling pressure values of 1.5...2.0 MPa. This effect becomes possible due to the introduction of components with a higher boiling point into the composition of the working fluid. In order to obtain higher operational characteristics, irreversible losses in J-T cryocoolers must be analyzed and ways of their reduction determined. The thermodynamic analysis of the installation cycle and subsequent design of the heat exchange equipment of cryocoolers formulates the conclusion that in order to optimize the design of the heat exchange equipment of the installation, which consists in solving hydrodynamic and thermal problems, a careful determination of the thermophysical properties of mixed working bodies is necessary. It should be taken into account that the principle of additivity is not always possible to apply for different compositions. By choosing certain components of the working body and changing their mass composition, it is possible to obtain the necessary properties. On the basis of experimental studies conducted at Ltd «DNIPRO MTV», the main components of the refrigerant were determined. When using mixed refrigerants, their thermophysical and calorific properties are determined taking into account the polarity of the molecules and the mass amount of the components of the mixture. Methods for determining thermophysical properties were analyzed, proposed by generalizing dependencies for determining the caloric properties of mixed refrigerants. the main components of the refrigerant are determined, namely: methane CH4, ethylene С2Н4, propane С3Н8 and isobutane С4Н10. The peculiarity of these substances is that they belong to hydrocarbons of the alkane series and are characterized by different values of thermophysical parameters. When calculating the parameters of the throttling and heat exchange processes, it is necessary to determine not only the integral characteristics, but also their values at certain parameters at the characteristic points of the process on the cycle diagram. Therefore, there is a need for obtained generalized dependencies both for individual components and for the mixture as a whole. With a significant number of options for parameters and components of the mixture, when determining the thermophysical properties of refrigerants, it is advisable to use empirical dependencies, where the values of the coefficients are obtained by processing experimental data. Bibl. 15, Fig. 1, Tab. 1.
- Open Access
- 29 August 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (8 (118)) , 51-59
Determining the influence of geometric factors and the type of heat carrier on the thermal resistance of miniature two-phase thermosyphons
This paper reports experimental data on the total thermal resistance of copper two-phase thermosiphons with internal diameters of 3 mm, 5 mm, and 9 mm, 700 mm long. Water, ethanol, methanol, and freon-113 were used as heat carriers. During the study, thermosiphons were located vertically. The length of the heating zone varied from 45 mm to 200 mm while the length of the condensation zone was constant and equaled 200 mm. The filling coefficient of thermosiphons varied from 0.3 to 2.0. Two series of experiments were conducted. The first series was distinguished by the fact that the filling coefficient of three thermosiphons with an internal diameter of 9 mm varied from 0.3 to 0.8 with the same length of the heating zone of 200 mm. The second series of experiments was carried out on thermosiphons with internal diameters of 3 mm and 5 mm. With the same amount of heat carrier, the length of the heating zone changed from 45 mm to 200 mm. As a result of research, it was determined that the total thermal resistance of thermosiphons is influenced by both their geometric factors (internal diameter and filling coefficient) and the type of heat carrier. The main factor that influenced the value of thermal resistance was also the transmitted heat flux. An increase in heat flow led to a significant decrease in thermal resistance. The maximum heat flux was determined with minimal thermal resistance. To calculate the value of the thermal resistance of thermosiphons, two dimensionless dependences were derived, which hold for two ranges of Reynolds numbers. For small Reynolds numbers (until 2000), which characterize the beginning of the action of vaporization centers and their gradual increase, the degree indicator was –0.8, and for larger Reynolds numbers, up to critical phenomena, the degree indicator was at the level of –0.3.
- 29 August 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 4 (8 (118)) , 51-59
Open AccessDetermining the influence of geometric factors and the type of heat carrier on the thermal resistance of miniature two-phase thermosyphons
This paper reports experimental data on the total thermal resistance of copper two-phase thermosiphons with internal diameters of 3 mm, 5 mm, and 9 mm, 700 mm long. Water, ethanol, methanol, and freon-113 were used as heat carriers. During the study, thermosiphons were located vertically. The length of the heating zone varied from 45 mm to 200 mm while the length of the condensation zone was constant and equaled 200 mm. The filling coefficient of thermosiphons varied from 0.3 to 2.0. Two series of experiments were conducted. The first series was distinguished by the fact that the filling coefficient of three thermosiphons with an internal diameter of 9 mm varied from 0.3 to 0.8 with the same length of the heating zone of 200 mm. The second series of experiments was carried out on thermosiphons with internal diameters of 3 mm and 5 mm. With the same amount of heat carrier, the length of the heating zone changed from 45 mm to 200 mm. As a result of research, it was determined that the total thermal resistance of thermosiphons is influenced by both their geometric factors (internal diameter and filling coefficient) and the type of heat carrier. The main factor that influenced the value of thermal resistance was also the transmitted heat flux. An increase in heat flow led to a significant decrease in thermal resistance. The maximum heat flux was determined with minimal thermal resistance. To calculate the value of the thermal resistance of thermosiphons, two dimensionless dependences were derived, which hold for two ranges of Reynolds numbers. For small Reynolds numbers (until 2000), which characterize the beginning of the action of vaporization centers and their gradual increase, the degree indicator was –0.8, and for larger Reynolds numbers, up to critical phenomena, the degree indicator was at the level of –0.3.