PSPeter Stalmans

Peter Stalmans

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Stalmans has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • General anesthesia significantly decreases arterial retrobulbar blood flow velocity in glaucoma patients

    by Joana Pargana, Koen Willekens, Karel Van Keer, Joachim Van Calster, Kathleen Deckers, Jan Vertommen, Evelien Vandewalle, Peter Stalmans, Ingeborg Stalmans, Luís Abegão Pinto

    Purpose: To investigate the influence of general anesthesia (GA)-induced systemic hypotension on retrobulbar blood flow and pressure flow-coupling in glaucomatous versus non-glaucomatous eyes. Methods: Prospective single-center case-control study including glaucoma and non-glaucomatous patients scheduled for ocular surgery under GA. Retrobulbar blood flow velocities were assessed with color Doppler imaging before and 1-min after GA induction simultaneous with blood pressure (BP) measurements. Linear mixed-effects models with random intercepts for subjects were used to evaluate the effects of group, time, and their interaction on MFV, adjusting for age, gender, intraocular pressure, statin, and systemic antihypertensive medication. A three-way interaction model analyzed pressure–flow coupling. Results: Twenty-seven glaucoma patients and 37 controls were included. GA induction caused comparable reductions in systolic BP in both groups ( p < 0.001). A significant group × time interaction was observed for MFV (β=−5.46 cm/s; p = 0.004). MFV remained stable in controls but decreased significantly in glaucoma patients. A significant group × time × MAP interaction ( p = 0.009) revealed altered pressure–flow coupling in glaucoma patients. No differences were observed between primary and secondary glaucoma. Conclusion: Glaucomatous eyes demonstrated impaired autoregulatory responses to GA-induced hypotension, suggesting increased vulnerability to perfusion stress during general anesthesia. Clinical trial registration: ClinicalTrials.gov identifier: NCT01840215

  • Open Access

    Clinical trial to test the safety of the EVA Nexus surgical platform

    by Stalmans Peter

    Background: The EVA Nexus system offers several technical improvements over its predecessor. The newly designed Aveta cannula system for vitrectomy surgery avoids the need for removal of the valve from the infusion cannula. The chamfered leading edge of the cannula also reduces the insertion force needed. The new EquiPhaco needles in combination with SmartIOP provide excellent anterior chamber stability during phaco-emulsification surgery, enabling to work at lower infusion pressures, and the multiburst phaco mode allows easier removal of hard cataracts. The system offers a secondary active infusion line for independent control of pressure to the anterior and posterior chambers, monitoring of flow rate/reflux and warning of infusion bottle emptying. This study evaluated whether these technical improvements result in improved surgical safety. Methods: In total, 250 eyes that underwent vitrectomy (53%) or phaco-vitrectomy (47%) using the EVA Nexus system were prospectively included. The occurrence of intraoperative adverse events was compared to that of historically operated eyes using the EVA system. Results: The average age of the patients was 63 years. A total of 33% of the patients were operated on for retinal detachment, 17% for macular pucker, 11% for treating floaters, 9% for removing silicone oil, 8% for macular hole repair and 22% for other diseases. In 75% of surgeries, 23 G instruments were used, and 27 G instruments were used in 25% of cases. Device issues that occurred included priming cycle issues (n = 4), eye pressure stability problems (n = 6) and vitrectome performance issues (n = 1), all of which in the first 100 patients who were included and were fixed with software updates. The frequency of surgical complications in the anterior segment was lower than that in the historically recorded surgical reports. Intraoperative events in the posterior segment included hemorrhage from retinal vessels, choroidal hematoma, iatrogenic retinal damage/tear, and subchoroidal infusion. Again, these events occurred rarely and less frequently than in the historical surgical reports. Conclusions: The EVA Nexus provides a surgical platform that reduces the incidence of intraoperative adverse events and iatrogenic complications in both anterior and posterior segment surgery. This could increase surgical safety during cataract and vitrectomy surgery. Trial Registration number Clinicaltrials.gov: : NCT05229094 Data 22/5/2021.


  • Efficacy and safety evaluation of Monoblue Dual View and Monoblue ILM View vital stains during vitrectomy surgery

    by Gauthier Blanckaert, Joris Vander Mijnsbrugge, Ann-Laure Delbecq, Jean-François Fils, Joyce Jansen, Joachim Van Calster, Peter Stalmans

    Purpose: To compare the staining properties of Monoblue inner limiting membrane (ILM) View and Monoblue DUAL View (study products) vital stains during vitrectomy surgery to those of ILM Blue or Membrane Blue Dual (control products).Methods: In this study, 105 patients were included in the Ophthalmic Clinic of the University Hospitals Leuven from September 2021 to April 2022. For prospective data collection in this study, patients were randomized between a control group (ILM Blue or Membrane Blue Dual, manufactured and commercialized by DORC®) and a study group (Monoblue ILM View or Monoblue DUAL View, manufactured and commercialized by Arcadophta®-BVI®). For retrospective data collection, patients were divided into similar surgery groups. Efficacy was analyzed using a binary subjective evaluation of the visualization of stained membranes during vitrectomy. The rate and severity of potential adverse events related to the study products were tracked, allowing both treatment groups to be compared with the corresponding control groups (ILM Blue and Membrane Blue Dual).Results: Based on the results and findings, none of the comparisons (primary outcomes) were statistically significant, showing similar efficacy of the dyes used. The study products were found to be safe in this study since no serious adverse events were reported.Conclusions: The present findings indicate that the Monoblue ILM View and Monoblue DUAL View dyes can safely be used during vitrectomy to stain the ILM and/or epiretinal membrane (ERM) when removal is needed.


  • Efficacy and safety of the implantation of a single-piece angulated foldable IOL in the sulcus

    by Gauthier Blanckaert, Joachim Van Calster, Joyce Jansen, Joris Vander Mijnsbrugge, Ann-Laure Delbecq, Ivo De Clerck, Jean-François Fils, Peter Stalmans

    Purpose To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL. Methods In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry. Results In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (p > 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (p < 0.05). Conclusion This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.


  • Open Access

    Clinical trial to test the safety of the EVA Nexus surgical platform

    by Stalmans Peter

    Background The EVA Nexus system offers several technical improvements over its predecessor. The newly designed Aveta cannula system for vitrectomy surgery avoids the need for removal of the valve from the infusion cannula. The chamfered leading edge of the cannula also reduces the insertion force needed. The new EquiPhaco needles in combination with SmartIOP provide excellent anterior chamber stability during phaco-emulsification surgery, enabling to work at lower infusion pressures, and the multiburst phaco mode allows easier removal of hard cataracts. The system offers a secondary active infusion line for independent control of pressure to the anterior and posterior chambers, monitoring of flow rate/reflux and warning of infusion bottle emptying. This study evaluated whether these technical improvements result in improved surgical safety. Methods In total, 250 eyes that underwent vitrectomy (53%) or phaco-vitrectomy (47%) using the EVA Nexus systemwere prospectively included. The occurrence of intraoperative adverse events was compared to that of historically operated eyes using the EVA system. Trial Registration number Clinicaltrials.gov: NCT05229094 Data 22/5/2021. Results The average age of the patients was 63 years. A total of 33% of the patients were operated on for retinal detachment, 17% for macular pucker, 11% for treating floaters, 9% for removing silicone oil, 8% for macular hole repair and 22% for other diseases. In 75% of surgeries, 23 G instruments were used, and 27 G instruments were used in 25% of cases. Device issues that occurred included priming cycle issues (n=4), eye pressure stability problems (n=6) and vitrectome performance issues (n=1), all of which in the first 100 patients who were included and were fixed with software updates. The frequency of surgical complications in the anterior segment was lower than that in the historically recorded surgical reports. Intraoperativeevents in the posterior segment included hemorrhage from retinal vessels, choroidal hematoma, iatrogenic retinal damage/tear, and subchoroidal infusion. Again, these events occurred rarely and less frequently than in the historical surgical reports. Conclusions The EVA Nexus provides a surgical platform that reduces the incidence of intraoperative adverse events and iatrogenic complications in both anterior and posterior segment surgery. This could increase surgical safety during cataract and vitrectomy surgery.

  • Patient satisfaction after EDOF intraocular lens implantation in vitrectomized eyes

    by Willem Van Hoe, Joachim Van Calster, Joyce Jansen, Joris Vander Mijnsbrugge, Ann-Laure Delbecq, Jean-François Fils, Peter Stalmans

    Purpose To report patient satisfaction after unilateral/bilateral extended depth-of-focus (EDOF) intraocular lens (IOL) implantation in a young population after vitrectomy. Methods Patients that underwent phaco-vitrectomy or phaco following vitrectomy with an AT LARA EDOF IOL, aged between 18 and 75 years, were asked to fill out a questionnaire to assess overall visual quality, near vision quality, and visual disturbances. The questionnaire was based on the Catquest, NAVQ, and APPLES questionnaires. Results A total of 89 participants (average age 56.7 years) filled out the questionnaire of which 53.9% received a unilateral EDOF IOL. The most common indications for vitrectomy were retinal detachments (38.2%), floaters (36.0%), and epiretinal membranes (16.9%). The Catquest and NAVQ score respectively showed a good overall satisfaction (3.44/4.0), a good intermediate vision (3.55/4.0), and an average near vision (2.75/4.0). The APPLES score showed acceptable visual disturbances. There were no differences between the unilateral and bilateral group, except for a higher spectacle dependency in the unilateral group (40% vs. 10.6%). Participants that underwent vitrectomy in case of floaters reported lower satisfaction rates. Other variables, like the pre-operative refraction, had no impact on both satisfaction and visual disturbances. Conclusion Both unilateral and bilateral implantation of the AT LARA EDOF IOL showed a high satisfaction with no differences between both groups, except for a lower spectacle use in the latter. Hence, The AT LARA seems to be a possible choice in patients undergoing vitrectomy at a younger age, even for unilateral use.


  • Open Access

    Investigation of the effectiveness of a new portable ‘cryopen’ probe for cryotherapy (CryoTreq®)

    by Peter Stalmans, Joris Vander Mijnsbrugge, Filip D’hOllander, Rita Van Ginderdeuren

    Background: To test the effectiveness of a new, innovative, single-use handheld ‘cryopen’ (CryoTreq®), which has been developed and marketed by Vitreq. Methods: Animal testing of cryopexy using the Cryotreq ® in two pig eyes was performed. Results: The biological effects of cryopexy were observed. Conclusions: During the surgery, the handheld device was comfortable to use and offers the surgeon more freedom to move. The cryotherapy caused severe atrophy and thinning of retinal layers, pigment epithelium and choroidea in a relatively uniform thickness. The cryopen is effective and offers advantages over non-handheld cryotherapy devices.


  • Open Access

    A Comparative Study of 23-Gauge and 27-Gauge Vitrectomy for Puckers or Floaters, Including Evaluation of the Effect of Combined Phaco-Vitrectomy Surgery on Postoperative Outcome

    by Peter Stalmans

    Introduction: A single-center, prospective randomized comparison of postoperative recovery between 23-gauge and 27-gauge surgical approaches in vitrectomy was performed. Methods: A single-center, prospective randomized comparison of postoperative recovery between 23-gauge and 27-gauge surgical approaches to evaluate efficiencies and postoperative outcomes of the two surgical gauges. Eighty patients who were scheduled to undergo pars plana vitrectomy (PPV) for floaters or macular surgery were treated with either 27-gauge or 23-gauge techniques and assessed for efficiency of the procedures as well as a variety of postop indicators of pain and inflammation. Results: 27-Gauge vitrectomy took 90 s more time compared to 23-gauge surgery. Wound closure was significantly easier in 27-gauge than 23-gauge. Less postoperative eye reddishness was seen in 27-gauge compared to 23-gauge. A trend towards less inflammation was seen in 27-gauge. Conclusion: Overall, the trial showed that 27-gauge has the better postoperative outcome compared to 23-gauge PPV. Combining vitrectomy with phaco-surgery did not influence the study outcome parameters.


  • Open Access

    Visual Outcome after Vitrectomy with Subretinal tPA Injection to Treat Submacular Hemorrhage Secondary to Age‐Related Macular Degeneration or Macroaneurysm

    by Yasmin Ali Said, Evelien Dewilde, Peter Stalmans

    Purpose . To determine the efficacy and safety of 23G transconjunctival sutureless vitrectomy, subretinal injection of tissue plasminogen activator using the EVA Surgical System, and pneumatic displacement with air to treat submacular hemorrhages. Methods . Retrospective analysis of 93 eyes surgically treated for submacular hemorrhage caused by neovascular AMD or retinal macroaneurysms. Main Outcome Measures . Postoperative visual acuity and surgical complications. Results . After surgery, visual acuity improved after 6 weeks but decreased again at the final postoperative visit at 8 months due to progression of the underlying disease. Complications consisted of 2 cases of retinal pigment epithelial tear, 7 vitreous hemorrhages, 4 hyphema, 6 cases of retinal detachment, and 2 subchoroidal hemorrhages during the follow‐up period. Conclusions . This study suggests that a surgical approach with 23G vitrectomy, subretinal tPA injection, and pneumatic displacement using air may be an effective procedure for submacular hemorrhage displacement in patients with AMD and retinal macroaneurysms. However, visual outcome is limited by the underlying macular pathology. Larger multicenter randomized controlled studies are warranted to determine the therapeutic effect of this surgical approach.


  • Phase I trial on robot assisted retinal vein cannulation with ocriplasmin infusion for central retinal vein occlusion

    by Koen Willekens, Andy Gijbels, Jonas Smits, Laurent Schoevaerdts, Johan Blanckaert, Jean H. M. Feyen, Dominiek Reynaerts, Peter Stalmans

    Purpose: To evaluate the safety and feasibility of robot‐assisted retinal vein cannulation with Ocriplasmin infusion for central retinal vein occlusion.Methods: Prospective phase I trial including four patients suffering from central retinal vein occlusion (CRVO). Diagnosis was confirmed by preoperative fluo‐angiography and followed by a standard three‐port pars plana vitrectomy. Afterwards, a custom‐built microneedle was inserted into a branch retinal vein with robotic assistance and infusion of Ocriplasmin started. Primary outcomes were the occurrence of intra‐operative complications and success of cannulation. Secondary outcomes were change in visual acuity, central macular thickness (CMT) and venous filling times (VFT) during fluo‐angiography two weeks after the intervention.Results: Cannulation with infusion of ocriplasmin was successful in all four eyes with a mean total infusion time of 355 ± 204 seconds (range 120–600 seconds). Best corrected visual acuity (BCVA) remained counting fingers (CF) in case 3 and 4, increased in case 1 from CF to 0.9LogMAR and decreased in case 2 from 0.4 to 1.3 LogMAR. CMT and VFT both showed a trend towards significant decrease comparing preoperative measurements with two weeks postintervention (1061 ± 541 μm versus 477 ± 376 μm, p = 0.068) and 24 ll 4 seconds versus 15 ± 1 seconds, p = 0.068, respectively). In one eye a needle tip broke and could be removed with an endoforceps. There were no other intervention‐related complications.Conclusion: Robot‐assisted retinal vein cannulation is feasible and safe. Local intravenous infusion with Ocriplasmin led to an improved retinal circulation.