Efficacy and safety of the implantation of a single-piece angulated foldable IOL in the sulcus
Authors:
- 11 April 2024
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 262 (9) , 2907-2915
Abstract
Purpose To study the visual results and tolerance of a Zeiss CT Lucia 601P intraocular lens (IOL) implanted in the sulcus after complicated cataract surgery or during IOL exchange for clouded IOL. Methods In total, 64 patients who underwent sulcus implantation were recalled to the hospital to undergo subjective and objective refraction, best corrected visual acuity measurement, tonometry, optical coherence tomography, laser flare photometry, biometry, and wavefront aberrometry. Results In spite of a large variation in preoperative refraction, the target refraction was obtained within 1.5 diopters in approximately 97% of patients and within 0.5 diopter in 53% of patients. Average BCVA was high (Snellen 0.86) and related to concomitant (mostly retinal) pathologies in eyes with poorer visual performance. Wavefront aberrometry showed no evidence of IOL tilting or decentration after long-term implantation in the sulcus. Tonometry was not different from the fellow eye of the patient (p > 0.5). In 53 patients with bilateral pseudophakia, the laser flare photometry was not significantly different from the fellow eye (p < 0.05). Conclusion This study demonstrates that this single-piece angulated foldable acrylic IOL can be considered for implantation in the sulcus. The visual results are favorable, and the IOL can be well-positioned and tolerated in the sulcus. Moreover, there were no safety issues found since there was no evidence of elevated IOP or chronic uveitis.Keywords
Funding Information
- Carl-Zeiss-Stiftung (Grant number S64878)
This publication has 13 references indexed in Scilit:
- Frequency of cataract surgery and its impact on visual function—results from the German Gutenberg Health StudyGraefe's Archive for Clinical and Experimental Ophthalmology, 2020
- Non-invasive Instrument-Based Tests for Quantifying Anterior Chamber Flare in Uveitis: A Systematic ReviewOcular Immunology and Inflammation, 2020
- Pseudouveitis and Iris Atrophy in Pigment Dispersion Syndrome after Sulcus Implantation of a One-Piece IOL with Square Edge Haptics (SN6AT6)Klinische Monatsblätter für Augenheilkunde, 2019
- Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchangeInternational Ophthalmology, 2017
- The importance of quantitative measurement methods for uveitis: laser flare photometry endorsed in Europe while neglected in Japan where the technology measuring quantitatively intraocular inflammation was developedInternational Ophthalmology, 2016
- Manual Small Incision Cataract Surgery2016
- Increasing incidence of cataract surgery: Population-based studyJournal of Cataract & Refractive Surgery, 2013
- Complications of sulcus placement of single-piece acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Laser flare-cell measurement of inflammation after uneventful extracapsular cataract extraction and intraocular lens implantationJournal of Cataract & Refractive Surgery, 1996
- Noncicatricial oval deformation of the pupil induced by sulcus-fixated one-piece posterior chamber lensesJournal of Cataract & Refractive Surgery, 1990