JZJing Zhang

Jing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jing Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Online Measuring Method for Tangent Delta of Power Cables Based on an Injected Very-Low-Frequency Signal

    by Jing Zhang, Yang Jiao, Qing Chen, Lei Zhou, Hongbin Li, Yue Tong

    The deterioration of cable insulation is a widely acknowledged problem, and detection lays the foundation for maintenance and overhaul. The measurement of Tangent delta (tan $\boldsymbol {\delta }$ ) at very low frequency (VLF) works well on cable insulation detection, nevertheless the conventional method could only be conducted offline, where the power outage is usually required, interrupting the normal operation. To break thus a limitation, an advanced online method is proposed, and tan $\boldsymbol {\delta }$ would be calculated based on the measurement of an artificially injected VLF voltage and that of the VLF leakage current through cable insulation. To coordinate with this method, an injecting source, with the comprehensive self-protection and the by-pass channel for power-frequency signals, is developed to safely inject a VLF voltage to the power system, and a monitoring system, with an accuracy better than $\pm 0.3~\boldsymbol {\mu }\text{A}$ , is established to obtain the injected voltage’s and leakage current’s waveforms, which would be used to further calculate tan $\boldsymbol {\delta }$ with the cross-correlation algorithm. In addition, this method, as well as developed devices, is applied on several cables in China Electric Power Research Institute, and the measuring results keep consistent with the actual conditions, which verifies the validity.


  • Multi-Band Field-Circuit Coupling Analysis Method for Very Fast Transient Overvoltage

    by Jing Zhang, Qing Chen, Hongbin Li, Yang Jiao, Lei Zhou, Yunwu Xu

    Very fast transient overvoltage (VFTO) is one of the most serious threats to gas insulated substations (GIS), while its formation mechanism has not been analyzed clearly by existing methods. Aimed at solving this problem, this paper proposes a multi-band field-circuit coupling analysis method from the perspective of energy exchange. To validate the proposed method's effectiveness, three equivalent models with different principle types are established to accurately model the GIS system, and a field test is conducted in China Electric Power Research Institute. The experimental results show that the measured waveforms are close to the simulation waveforms in the time domain, and the proposed method could accurately analyze VFTO in the full frequency domain.