Shilin Hou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shilin Hou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jiyan Y. Dai
Department of Applied Physics The Hong Kong Polytechnic University Hong Kong China
3 shared publications Qiandong Sun
Department of Biomedical Engineering, Fudan University, Shanghai 200438, China
3 shared publicationsChunxiao Zou
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Provincial Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Health Sciences Center, Shenzhen, China
2 shared publicationsHu Tang
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Provincial Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Health Sciences Center, Shenzhen, China
2 shared publications- Jue Peng
School of Biomedical Engineering, Shenzhen University Medical School Shenzhen University
2 shared publications - Kailiang Xu
College of Biomedical Engineering, Fudan University, Shanghai, China
2 shared publications
Latest Publications
- 14 September 2025
- Published by Elsevier in Ultrasonics
- Vol. 158, 107814
A new row-column-addressed transducer for 3D ultrasound imaging
- 14 September 2025
- Published by Elsevier in Ultrasonics
- Vol. 158, 107814
A new row-column-addressed transducer for 3D ultrasound imaging
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 698-708
Single-Crystal Row–Column Array-Based Rat Brain 3-D Ultrasound Localization Microscopy
Ultrasound localization microscopy (ULM) enables imaging of cerebral vasculature at microscopic scale with deep penetration. However, conventional two-dimensional (2D) ULM suffers from the elevation projection and cannot capture the outof- plane vessels. Recently developed volumetric ULM overcomes the limitations by providing isotropic resolution and enabling comprehensive visualization of the microvascular architecture in three dimensions. In this study, we developed a single crystal 128 + 128 row-column addressed (RCA) probe centered at 13 MHz, with a bandwidth of 80% and a large aperture of 15.36 × 15.36 mm2, which is suitable for volumetric imaging of small animals and superficial organs. Three-dimensional rendering of superresolved vascular density and velocity maps was performed to visualize the cerebral vasculature at an improved spatial resolution of 24.7 μm. The developed methodology demonstrated the performance of single-crystal RCA based in vivo volumetric imaging of micro-cerebrovascular, highlighting its high potential for studying neurodegenerative diseases, intracranial aneurysms, and stroke.
- 23 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 698-708
Single-Crystal Row–Column Array-Based Rat Brain 3-D Ultrasound Localization Microscopy
Ultrasound localization microscopy (ULM) enables imaging of cerebral vasculature at microscopic scale with deep penetration. However, conventional two-dimensional (2D) ULM suffers from the elevation projection and cannot capture the outof- plane vessels. Recently developed volumetric ULM overcomes the limitations by providing isotropic resolution and enabling comprehensive visualization of the microvascular architecture in three dimensions. In this study, we developed a single crystal 128 + 128 row-column addressed (RCA) probe centered at 13 MHz, with a bandwidth of 80% and a large aperture of 15.36 × 15.36 mm2, which is suitable for volumetric imaging of small animals and superficial organs. Three-dimensional rendering of superresolved vascular density and velocity maps was performed to visualize the cerebral vasculature at an improved spatial resolution of 24.7 μm. The developed methodology demonstrated the performance of single-crystal RCA based in vivo volumetric imaging of micro-cerebrovascular, highlighting its high potential for studying neurodegenerative diseases, intracranial aneurysms, and stroke.
- 11 March 2024
- Published by Elsevier in Ultrasonics
- Vol. 139, 107289
A single crystal row–column-array for 3D ultrasound imaging
- 11 March 2024
- Published by Elsevier in Ultrasonics
- Vol. 139, 107289
A single crystal row–column-array for 3D ultrasound imaging
- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (2) , 744-750
Development of Cardiac Phased Array With Large-Size PZN-5.5 %PT Single Crystals
In recent years, the manufacturing process of lead zinc niobate-lead titanate [Pb(Zn1/3Nb2/3)O3-PbTiO3, also called PZN-PT], has been enhanced with improvements in size, consistency, and a suitable compromise between piezoelectric properties and phase transition temperature, which means that it is possible to obtain PZN-PT single crystals in sufficient size for performance characterization studies and batch manufacturing to produce high-performance medical ultrasonic transducers. This article mainly focuses on the development of the 64-element phased array ultrasonic transducer based on novel large-size PZN-PT piezoelectric single crystals. The composition of the single crystal was chosen as PZN-5.5 %PT. The designed center frequency of the phased array is 3.0 MHz, which is suitable for cardiac ultrasound imaging. The array elements were spaced at a 0.254-mm pitch, and interconnected through a custom-designed flexible circuit. Double matching layers with a light backing structure were applied in the transducer fabrication process to improve the performance of the array. The test results of the developed phased array showed a center frequency of 3.0 MHz, and an average -6 dB fractional bandwidth of 72%. In the vicinity of the center frequency, the two-way insertion loss (IL) was about −46 dB, while a crosstalk between the adjacent elements was less than −31 dB. The wire phantom can be distinctly imaged with the phased array, and the axial and lateral resolutions were measured to be 660 and$1299 \mu \text{m}$ , respectively. The image of a standard phantom was acquired to present the imaging performance of the transducer. The final results indicate that the transducer arrays based on novel large-size PZN-PT single crystals are quite promising for use in medical ultrasound imaging applications.- 19 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (2) , 744-750
Development of Cardiac Phased Array With Large-Size PZN-5.5 %PT Single Crystals
In recent years, the manufacturing process of lead zinc niobate-lead titanate [Pb(Zn1/3Nb2/3)O3-PbTiO3, also called PZN-PT], has been enhanced with improvements in size, consistency, and a suitable compromise between piezoelectric properties and phase transition temperature, which means that it is possible to obtain PZN-PT single crystals in sufficient size for performance characterization studies and batch manufacturing to produce high-performance medical ultrasonic transducers. This article mainly focuses on the development of the 64-element phased array ultrasonic transducer based on novel large-size PZN-PT piezoelectric single crystals. The composition of the single crystal was chosen as PZN-5.5 %PT. The designed center frequency of the phased array is 3.0 MHz, which is suitable for cardiac ultrasound imaging. The array elements were spaced at a 0.254-mm pitch, and interconnected through a custom-designed flexible circuit. Double matching layers with a light backing structure were applied in the transducer fabrication process to improve the performance of the array. The test results of the developed phased array showed a center frequency of 3.0 MHz, and an average -6 dB fractional bandwidth of 72%. In the vicinity of the center frequency, the two-way insertion loss (IL) was about −46 dB, while a crosstalk between the adjacent elements was less than −31 dB. The wire phantom can be distinctly imaged with the phased array, and the axial and lateral resolutions were measured to be 660 and$1299 \mu \text{m}$ , respectively. The image of a standard phantom was acquired to present the imaging performance of the transducer. The final results indicate that the transducer arrays based on novel large-size PZN-PT single crystals are quite promising for use in medical ultrasound imaging applications.- 22 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 283-290
A Novel Distal Micromotor-Based Side-Looking Intravascular Ultrasound Transducer
Cardiovascular disease has become one of the leading causes of death in China, accounting for 45.5% of all deaths in rural areas and 43.16% in urban areas. Hence, its early diagnosis is important. With the development of intravascular imaging technology, the intravascular ultrasound (IVUS) is widely used. The available commercial mechanical rotary side-looking IVUS (SL-IVUS) transducers are driven by external motors that use long flexible shafts to transmit the rotation. However, when the transducer passes through a long-curved blood vessel, it easily causes the nonuniform rotation distortion (NURD) of the image. A catheter which contains a distal motor and sodium chloride (NaCl) solution is presented in this study as an attempt to solve such issues. The NaCl solution is used to connect the transducer and micromotor so that the motor can directly drive the transducer to rotate and acquire the information of the blood vessel. The results showed that the center frequency and −6-dB fraction bandwidth of the single element were 47 MHz and 98%, respectively. The SL-IVUS catheter consists of a distal motor, with speed stability and high resolution, and has the potential to diagnose cardiovascular disease. This novel structure can decrease the dimension at the top of the catheter and reduce the risks of clinical diagnosis.
- 22 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 283-290
A Novel Distal Micromotor-Based Side-Looking Intravascular Ultrasound Transducer
Cardiovascular disease has become one of the leading causes of death in China, accounting for 45.5% of all deaths in rural areas and 43.16% in urban areas. Hence, its early diagnosis is important. With the development of intravascular imaging technology, the intravascular ultrasound (IVUS) is widely used. The available commercial mechanical rotary side-looking IVUS (SL-IVUS) transducers are driven by external motors that use long flexible shafts to transmit the rotation. However, when the transducer passes through a long-curved blood vessel, it easily causes the nonuniform rotation distortion (NURD) of the image. A catheter which contains a distal motor and sodium chloride (NaCl) solution is presented in this study as an attempt to solve such issues. The NaCl solution is used to connect the transducer and micromotor so that the motor can directly drive the transducer to rotate and acquire the information of the blood vessel. The results showed that the center frequency and −6-dB fraction bandwidth of the single element were 47 MHz and 98%, respectively. The SL-IVUS catheter consists of a distal motor, with speed stability and high resolution, and has the potential to diagnose cardiovascular disease. This novel structure can decrease the dimension at the top of the catheter and reduce the risks of clinical diagnosis.