Single-Crystal Row–Column Array-Based Rat Brain 3-D Ultrasound Localization Microscopy
- 23 April 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 698-708
Abstract
Ultrasound localization microscopy (ULM) enables imaging of cerebral vasculature at microscopic scale with deep penetration. However, conventional two-dimensional (2D) ULM suffers from the elevation projection and cannot capture the outof- plane vessels. Recently developed volumetric ULM overcomes the limitations by providing isotropic resolution and enabling comprehensive visualization of the microvascular architecture in three dimensions. In this study, we developed a single crystal 128 + 128 row-column addressed (RCA) probe centered at 13 MHz, with a bandwidth of 80% and a large aperture of 15.36 × 15.36 mm2, which is suitable for volumetric imaging of small animals and superficial organs. Three-dimensional rendering of superresolved vascular density and velocity maps was performed to visualize the cerebral vasculature at an improved spatial resolution of 24.7 μm. The developed methodology demonstrated the performance of single-crystal RCA based in vivo volumetric imaging of micro-cerebrovascular, highlighting its high potential for studying neurodegenerative diseases, intracranial aneurysms, and stroke.Keywords
Funding Information
- Hong Kong RGC Collaborative Research Fund (No. C5053-22G)
- National Key Research and Development Program of China (2023YFC2410900)
This publication has 79 references indexed in Scilit:
- 3D ultrasound localization microscopy of the nonhuman primate brainEBioMedicine, 2024
- Evaluation of tumor microvasculature with 3D ultrasound localization microscopy based on 2D matrix arrayEuropean Radiology, 2024
- Three‐dimensional super resolution ultrasound imaging with a multi‐frequency hemispherical phased arrayMedical Physics, 2023
- Sensing ultrasound localization microscopy for the visualization of glomeruli in living rats and humansEBioMedicine, 2023
- Ultrasound localization microscopy of the human kidney allograft on a clinical ultrasound scannerKidney International, 2023
- In vivo whole brain microvascular imaging in mice using transcranial 3D Ultrasound Localization MicroscopyEBioMedicine, 2022
- Coronary Flow Assessment Using 3-Dimensional Ultrafast Ultrasound Localization MicroscopyJACC: Cardiovascular Imaging, 2022
- High‐resolution magnetic resonance angiography in the mouse using a nanoparticle blood‐pool contrast agentMagnetic Resonance in Medicine, 2009
- Measurement of cerebral blood volume in mouse brain regions using micro-computed tomographyNeuroImage, 2009
- The Hungarian method for the assignment problemNaval Research Logistics Quarterly, 1955