Jeongin Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeongin Moon has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jooeun Ahn
Department of Physical Education, Seoul National University, Seoul, South Korea
5 shared publications Changhyun Roh
Affiliation WI Robotics, Suwon, Gyeonggi, Republic of Korea
2 shared publications- Eunsik Choi
Sports Engineering Laboratory in the Department of Physical Education; Institute of Sport Science, Seoul National University, Seoul, South Korea
2 shared publications - Jangwhan Ahn
North Carolina State University
2 shared publications - Prabhat Pathak
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
2 shared publications Se-Gon Roh
Affiliation Robot Center in Samsung Seoul R&D Campus, Samsung Electronics Co., Ltd., Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0361338
Dissociation between muscle activation, spinal joint load, and subjective perception in passive back support exoskeleton use
One important purpose of back support exoskeletons (BSEs) is to reduce the stress to the lumbar spine and alleviate the low back pain. However, most previous studies introducing BSEs have argued for their effectiveness based only on easily measurable physiological outcomes such as muscle activation. Motivated by this gap, we examined whether the muscle activation of the back muscle during load handling with a passive BSE can faithfully reflect the estimated L5–S1 joint reaction forces and subjective perceptions. Experiments involving 12 healthy young adults revealed that the BSE significantly reduced average thoracic erector spinae muscle activation during both lifting and lowering the load, and lumbar erector spinae muscle activation during lowering. The BSE also reduced integrated thoracic erector spinae muscle activation during lowering. L5–S1 joint reaction forces were also significantly reduced by the BSE (p < 0.001). Participants reported a lower rate of perceived exertion (p < 0.05). However, the lack of associations among all metrics suggests that inferring one measure from another remains limited when evaluating the efficacy of a BSE.
- 26 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0361338
Open AccessDissociation between muscle activation, spinal joint load, and subjective perception in passive back support exoskeleton use
One important purpose of back support exoskeletons (BSEs) is to reduce the stress to the lumbar spine and alleviate the low back pain. However, most previous studies introducing BSEs have argued for their effectiveness based only on easily measurable physiological outcomes such as muscle activation. Motivated by this gap, we examined whether the muscle activation of the back muscle during load handling with a passive BSE can faithfully reflect the estimated L5–S1 joint reaction forces and subjective perceptions. Experiments involving 12 healthy young adults revealed that the BSE significantly reduced average thoracic erector spinae muscle activation during both lifting and lowering the load, and lumbar erector spinae muscle activation during lowering. The BSE also reduced integrated thoracic erector spinae muscle activation during lowering. L5–S1 joint reaction forces were also significantly reduced by the BSE (p < 0.001). Participants reported a lower rate of perceived exertion (p < 0.05). However, the lack of associations among all metrics suggests that inferring one measure from another remains limited when evaluating the efficacy of a BSE.
- Open Access
- 13 August 2025
- Published by The Royal Society in Royal Society Open Science
- Vol. 12 (8) , 250106
The effect of sampling methods on the validity and reliability of the estimation of the orbital stability of human gait
Floquet multiplier (FM) is a commonly used metric for evaluating gait orbital stability in biomechanics. However, variability of human gait and noise from various sources can induce significant bias and variance in the estimation of FM. Furthermore, FM is employed in gait analysis without standardized protocols, leading to highly case-dependent outcomes. To address these challenges, we quantify the effects of sampling conditions on the accuracy and consistency of FM estimations. We recruited 20 healthy participants and conducted five trials of 10 minutes of walking per participant. Using individualized Jacobian matrices calculated from the walking experiments, we synthesized multiple sets of virtual time series with varying lengths and trial counts. Using stochastic linear models, we simulated the error dynamics depending on the sampling methods. The bias and variance of FM estimates decreased as the time series lengthened, achieving a strong correlation with the true value after 140 strides for 14-dimensional state vector. Our results further suggest that partitioning a long time series into appropriately sized segments can yield more reliable FM estimates, reducing both bias and variance in FM estimations.
- 13 August 2025
- Published by The Royal Society in Royal Society Open Science
- Vol. 12 (8) , 250106
Open AccessThe effect of sampling methods on the validity and reliability of the estimation of the orbital stability of human gait
Floquet multiplier (FM) is a commonly used metric for evaluating gait orbital stability in biomechanics. However, variability of human gait and noise from various sources can induce significant bias and variance in the estimation of FM. Furthermore, FM is employed in gait analysis without standardized protocols, leading to highly case-dependent outcomes. To address these challenges, we quantify the effects of sampling conditions on the accuracy and consistency of FM estimations. We recruited 20 healthy participants and conducted five trials of 10 minutes of walking per participant. Using individualized Jacobian matrices calculated from the walking experiments, we synthesized multiple sets of virtual time series with varying lengths and trial counts. Using stochastic linear models, we simulated the error dynamics depending on the sampling methods. The bias and variance of FM estimates decreased as the time series lengthened, achieving a strong correlation with the true value after 140 strides for 14-dimensional state vector. Our results further suggest that partitioning a long time series into appropriately sized segments can yield more reliable FM estimates, reducing both bias and variance in FM estimations.
- Open Access
- 6 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0266597
Supra-threshold vibration applied to the foot soles enhances jump height under maximum effort
Previous studies have shown that absence or reduction of cutaneous sensory feedback can diminish human motor performance under maximum effort. However, it has not been explored whether any appropriate intervention in the cutaneous sensory input can augment the output motor performance, particularly in motor tasks such as jumping that involve the kinematic chain of the entire body. Using shoes with active vibrating insoles, we applied mechanical vibration to the soles of 20 young and healthy adults and evaluated the change in the jump height and muscle activation using within-participants repeated measures. The noise-like vibration having an amplitude of 130% of the sensory threshold of each participant led to an average increase of 0.38 cm in the jump height (p = 0.008) and activation of the rectus femoris of the dominant leg (p = 0.011). These results indicate that application of a properly designed cutaneous stimulus to the soles, the distal end effectors of motor tasks, can augment the output performance by involving the prime movers distant from the end effector.
- 6 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0266597
Open AccessSupra-threshold vibration applied to the foot soles enhances jump height under maximum effort
Previous studies have shown that absence or reduction of cutaneous sensory feedback can diminish human motor performance under maximum effort. However, it has not been explored whether any appropriate intervention in the cutaneous sensory input can augment the output motor performance, particularly in motor tasks such as jumping that involve the kinematic chain of the entire body. Using shoes with active vibrating insoles, we applied mechanical vibration to the soles of 20 young and healthy adults and evaluated the change in the jump height and muscle activation using within-participants repeated measures. The noise-like vibration having an amplitude of 130% of the sensory threshold of each participant led to an average increase of 0.38 cm in the jump height (p = 0.008) and activation of the rectus femoris of the dominant leg (p = 0.011). These results indicate that application of a properly designed cutaneous stimulus to the soles, the distal end effectors of motor tasks, can augment the output performance by involving the prime movers distant from the end effector.
- Open Access
- 4 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0261732
Application of vibration to the soles reduces minimum toe clearance variability during walking
Minimum toe clearance (MTC) is an important indicator of the risk of tripping. Aging and neuromuscular diseases often decrease MTC height and increase its variability, leading to a higher risk of tripping. Previous studies have developed visual feedback-based gait training systems to modify MTC. However, these systems are bulky and expensive, and the effects of the training continue only for a short time. We paid attention to the efficacy of vibration in decreasing the variability of gait parameters, and hypothesized that proper vibration applied to soles can reduce the MTC variability. Using shoes embedded with active vibrating insoles, we assessed the efficacy of both sub- and supra-threshold vibration in affecting MTC distribution. Experiment results with 17 young and healthy adults showed that vibration applied throughout the walking task with constant intensity of 130% of sensory threshold significantly decreased MTC variability, whereas sub-threshold vibration yielded no significant effect. These results demonstrate that a properly designed tactile sensory input which is controlled and delivered by a simple wearable device, the active insole, can reduce the MTC variability during walking.
- 4 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0261732
Open AccessApplication of vibration to the soles reduces minimum toe clearance variability during walking
Minimum toe clearance (MTC) is an important indicator of the risk of tripping. Aging and neuromuscular diseases often decrease MTC height and increase its variability, leading to a higher risk of tripping. Previous studies have developed visual feedback-based gait training systems to modify MTC. However, these systems are bulky and expensive, and the effects of the training continue only for a short time. We paid attention to the efficacy of vibration in decreasing the variability of gait parameters, and hypothesized that proper vibration applied to soles can reduce the MTC variability. Using shoes embedded with active vibrating insoles, we assessed the efficacy of both sub- and supra-threshold vibration in affecting MTC distribution. Experiment results with 17 young and healthy adults showed that vibration applied throughout the walking task with constant intensity of 130% of sensory threshold significantly decreased MTC variability, whereas sub-threshold vibration yielded no significant effect. These results demonstrate that a properly designed tactile sensory input which is controlled and delivered by a simple wearable device, the active insole, can reduce the MTC variability during walking.