Eunsik Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eunsik Choi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jooeun Ahn
Department of Physical Education, Seoul National University, Seoul, South Korea
3 shared publications - Jangwhan Ahn
North Carolina State University
2 shared publications - Jeongin Moon
University of Massachusetts Lowell
2 shared publications Beomdo Kim
Sports Engineering Laboratory in the Department of Physical Education; Institute of Sport Science, Seoul National University, Seoul, South Korea
1 shared publication- Chihyeong Lee
Sports Engineering Laboratory in the Department of Physical Education; Institute of Sport Science, Seoul National University, Seoul, South Korea
1 shared publication Hyeonhee Jung
Asan Institute for Life Sciences, Asan Medical Center
1 shared publication
Latest Publications
- Open Access
- 26 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0361338
Dissociation between muscle activation, spinal joint load, and subjective perception in passive back support exoskeleton use
One important purpose of back support exoskeletons (BSEs) is to reduce the stress to the lumbar spine and alleviate the low back pain. However, most previous studies introducing BSEs have argued for their effectiveness based only on easily measurable physiological outcomes such as muscle activation. Motivated by this gap, we examined whether the muscle activation of the back muscle during load handling with a passive BSE can faithfully reflect the estimated L5–S1 joint reaction forces and subjective perceptions. Experiments involving 12 healthy young adults revealed that the BSE significantly reduced average thoracic erector spinae muscle activation during both lifting and lowering the load, and lumbar erector spinae muscle activation during lowering. The BSE also reduced integrated thoracic erector spinae muscle activation during lowering. L5–S1 joint reaction forces were also significantly reduced by the BSE (p < 0.001). Participants reported a lower rate of perceived exertion (p < 0.05). However, the lack of associations among all metrics suggests that inferring one measure from another remains limited when evaluating the efficacy of a BSE.
- 26 October 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (10) , e0361338
Open AccessDissociation between muscle activation, spinal joint load, and subjective perception in passive back support exoskeleton use
One important purpose of back support exoskeletons (BSEs) is to reduce the stress to the lumbar spine and alleviate the low back pain. However, most previous studies introducing BSEs have argued for their effectiveness based only on easily measurable physiological outcomes such as muscle activation. Motivated by this gap, we examined whether the muscle activation of the back muscle during load handling with a passive BSE can faithfully reflect the estimated L5–S1 joint reaction forces and subjective perceptions. Experiments involving 12 healthy young adults revealed that the BSE significantly reduced average thoracic erector spinae muscle activation during both lifting and lowering the load, and lumbar erector spinae muscle activation during lowering. The BSE also reduced integrated thoracic erector spinae muscle activation during lowering. L5–S1 joint reaction forces were also significantly reduced by the BSE (p < 0.001). Participants reported a lower rate of perceived exertion (p < 0.05). However, the lack of associations among all metrics suggests that inferring one measure from another remains limited when evaluating the efficacy of a BSE.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 4428-4435
Design of a Fully-Soft Lift-Assist Wearable Suit Powered by Flat Inflatable Artificial Muscles
The development of soft pneumatic actuators has expanded their applications due to flexibility and adaptability in wearable systems. Among these, flat inflatable artificial muscles (FIAMs) show a significant potential for wearable robots designed to assist body movements. While existing devices focus on supporting specific joints, an integrated system for multiple joints has not yet been realized. This study introduces a fully soft wearable suit incorporating FIAMs to assist lifting motions through combined actuation of the arms and back. The design and fabrication process of FIAMs are described, along with a force estimation model adapted for integration with the wearable suit. The experimental validation demonstrates robust and consistent performance of FIAMs under cyclic testing. The modular structure allows seamless integration into the wearable suit, enabling active assistance for targeted muscle groups. Human testing is conducted using weight-lifting tasks to evaluate the suit. Muscle activation and respiratory indices are measured to quantify the effects of the suit. The results demonstrate a partial reduction in metabolic cost expenditure, indicating the potential of this wearable suit for physical assistance in daily and occupational tasks.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 4428-4435
Design of a Fully-Soft Lift-Assist Wearable Suit Powered by Flat Inflatable Artificial Muscles
The development of soft pneumatic actuators has expanded their applications due to flexibility and adaptability in wearable systems. Among these, flat inflatable artificial muscles (FIAMs) show a significant potential for wearable robots designed to assist body movements. While existing devices focus on supporting specific joints, an integrated system for multiple joints has not yet been realized. This study introduces a fully soft wearable suit incorporating FIAMs to assist lifting motions through combined actuation of the arms and back. The design and fabrication process of FIAMs are described, along with a force estimation model adapted for integration with the wearable suit. The experimental validation demonstrates robust and consistent performance of FIAMs under cyclic testing. The modular structure allows seamless integration into the wearable suit, enabling active assistance for targeted muscle groups. Human testing is conducted using weight-lifting tasks to evaluate the suit. Muscle activation and respiratory indices are measured to quantify the effects of the suit. The results demonstrate a partial reduction in metabolic cost expenditure, indicating the potential of this wearable suit for physical assistance in daily and occupational tasks.