KKKundan Kumar

Kundan Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kundan Kumar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-Time Cyber-Physical Co-Simulation for Resilient Wide-Area Damping Control Against FDIAs and Communication Disruptions

    by Kundan Kumar, Priyesh Saini, Abhineet Prakash, Sanjoy K. Parida, Khaled Ali Al Jaafari, Hatem H. Zeineldin, Ehab F. El-Saadany

    Integration of Renewable Energy Sources (RESs) into modern power systems presents a myriad of challenges, foremost among them being the pressing demand for a simulation platform capable of accurately replicating the intricate dynamics of these complex systems. This paper presents the implementation and outcomes of a Real-Time Cyber-Physical Testbed Co-simulation with Hardware-in-the-Loop (RTCPTC-HIL) approach to evaluate the effectiveness of the proposed Wide-Area Damping Controller (WADC) with HVDC in mitigating inter-area oscillations in large-scale RESs integrated power systems. The testbed integrates OPAL-RT OP4510 for system modeling and OP8665 for controller development and testing, with real-time communication via physical connections and TCP/IP. Moreover, WADC functionality depends on remote measurements acquired from PMUs, which are vulnerable to disruptions and cyber-attacks, potentially compromising controller performance. To address this, a machine learning-based signal reconstruction framework leveraging CNN-LSTM is proposed to enhance WADC resilience against communication disturbances and anomalies. A 25-generator, 105-bus truncated model of India's Eastern Regional grid is utilized for validation of proposed framework.


  • A Novel Modal Eigenvalue Realignment-Based Design of Wide-Area Damping Controller for Inter-Area Oscillations in Modern Power System

    by Kundan Kumar, Abhineet Prakash, Khaled Al Jaafari, S. K. Parida

    This letter proposes a novel method to extract singlemode feedback signals using a modal eigenvalue realignment (MER) based approach. The single-mode feedback signals those contain information pertinent to the concerned modes are selected, while states with minimal participation are disregarded. These signals are utilized as supplementary inputs to highvoltage direct current (HVDC) tie-line converter and exciters of synchronous generators (SGs) aiming to enhance the damping of inter-area modes (IAMs) of oscillation. The proposed method is thoroughly evaluated and validated using a 25-machine, 105-bus Eastern Regional (ER) truncated power system of India, and further verified through real-time hardware-in-the-loop (HIL) simulation.


  • A Novel Multi-Functional Observer Based Distributed WADC for Large Power System Using Modified Decoupled Control Approach

    by Kundan Kumar, Abhineet Prakash, Sanjoy Kumar Parida, Saibal Ghosh, Chandan Kumar

    Feeble damping of inter-area oscillations presents a consequential threat to modern power systems, leading to power swings, voltage fluctuations, and potential system instability, which could result in blackouts. To tackle this issue, this article introduces a novel Multi-Functional Observer (MFO) based Wide-Area Damping Controller (WADC) design. The WADC gain and selection of feedback signals are determined using the Modified Decoupled Control (MDC) approach. As the direct input signals to the WADC are not available through phasor measurement units (PMUs), the study utilizes MFOs to estimate the chosen feedback signals based on PMU data. These estimated feedback signals are used as supplementary inputs to the High-Voltage Direct Current (HVDC) tie-line converter and exciter of selected machines to enhance system stability in a distributed manner. The proposed approach is rigorously tested and validated on a complex 25-machine, 105-bus practical system, which represents a truncated model of India's Eastern Regional (ER) Grid. Furthermore, Non-linear simulation results indicate that the proposed WADC algorithm effectively dampens multiple inter-area modes while leaving other modes almost unaffected. The proposed MFO-based WADC adopted Interacting Multiple Model (IMM) strategy to validate robust damping performance for large uncertainties in operating points.


  • Damping of Inter-Area Oscillations With Frequency Regulation in Power Systems Considering High Penetration of Renewable Energy Sources

    by Abhineet Prakash, Mohamed Shawky El Moursi, S. K. Parida, Kundan Kumar, Ehab F. El-Saadany

    Due to high penetration of renewable energy sources, inter-area oscillations (IAOs) have become serious concern for power system stability. Hence, a wide-area damping controller (WADC) strategy is proposed for thyristor-controlled series compensator (TCSC) device to effectively damp IAOs. The feedback signals for the WADC design are selected by the modal sparse linear quadratic regulator (MSLQR) method, which are sole signals that modulate simple gains to achieve the desired damping performance. Moreover, the multi-model framework approach is adopted to ensure optimal damping corresponding to any uncertainties such as changing operating scenarios and time latency in feedback signals. However, the proposed primary control does not provide frequency regulation; hence, a secondary control based on the switched integral controller is applied in addition to primary damping control to further maintain the frequency at the steady-state level. Performance of suggested strategy is evaluated and verified on IEEE 4-machine, 11- bus system, and 16-machine, 68- bus system. A comprehensive analysis shows significant improvement in the damping performance of concerned modes, leaving the local modes almost unaffected while maintaining the frequency at the prescribed steady-state level.


  • Damping of Inter-Area Oscillations Using TCPS Based Delay Compensated Robust WADC

    by Abhineet Prakash, Kundan Kumar, S. K. Parida

    Low-frequency oscillations (LFOs) pose a significant obstacle in achieving optimal power flow and utilizing transmission corridors in large interconnected power systems. In this study, linear matrix inequality (LMI) base robust H∞ wide-area damping controller (WADC) is introduced to effectively address critical LFOs. The proposed WADC utilizes wide-area signals, which modulate the phase angle of a thyristor-controlled phase shifter device. To ensure that the concerned modes of LFOs lie in left half of the complex plane, a D-space sub-region approach is applied. However, using wide-area signals introduces time delays, which negatively impact the efficacy of the WADC; hence, a time delay compensator (TDC) is incorporated into the feedback path of the signals. The proposed approach involves four key steps: selecting feedback signals using a combined modal transformation and geometric approach, designing an appropriate TDC, building a generalized plant with mixed sensitivity weights, and solving the LMI. The dynamic efficacy is verified on IEEE 4-machine 11-bus system, and 10-machine 39-bus system. Poorly damped single and multiple critical modes are placed in the D-space region of interest with specified damping ratios viz. 10% and 15%. Furthermore, damping ratios of critical modes are maintained with TDC based proposed WADC while deteriorating with other counterparts.


  • Large-Scale Solar PV Converter Based Robust Wide-Area Damping Controller for Critical Low Frequency Oscillations in Power Systems

    by Kundan Kumar, Abhineet Prakash, Priya Singh, S. K. Parida

    Integration of large-scale renewable energy sources in legacy power system has negative impact on inertia and low-frequency oscillations (LFOs). Critical LFO modes are the primary concern in system stability as they limit the power transfer capability in inter-region tie-lines. Therefore, to provide adequate damping to critical LFO modes, a robust wide-area damping controller (WADC) design is required. In this paper, time delayed feedback control (TDFC) based WADC design is carried out with large-scale solar photovoltaic (SPV). In the design process, geometric technique is used to determine the appropriate wide-area signals. Time delays and noises in feedback signals as well as different operating scenarios have severe implications on the damping performance of WADC. Hence, considering these uncertainties, the proposed WADC parameters are tuned by modified particle swarm optimization (PSO) algorithm. The performance of proposed WADC is demonstrated on SPV-integrated IEEE 4-machine 11-bus and 16-machine 68-bus systems. Critical modes of the system are damped by more than 10 % damping ratio in both cases. Furthermore, nonlinear dynamic simulations demonstrate that the proposed WADC provides robust performance over wide operating scenarios. Finally, practical efficacy of the proposed method is established by experimental validation through real-time simulation using OPAL-RT.


  • Interacting Multiple Model Strategy Based Adaptive Wide-Area Damping Controller Design for Wind Farm Embedded Power System

    by Abhineet Prakash, Ranjeet Kumar Tiwari, Kundan Kumar, S. K. Parida

    The intermittent nature of Wind Turbine Systems (WTSs) can severely affect the Low-Frequency Oscillations (LFOs) in the power system. Hence, a Wide-Area Damping Controller (WADC) is designed in this paper to provide adequate damping to critical LFO modes. This WADC utilizes a modal-based prescribed degree approach, ensuring the specified shift of concerned modes from their existing position. However, the design of WADC at a fixed operating point and time delay in feedback signals does not provide robust performance as these uncertainties may vary for different time intervals. Specifically, time-varying delays should be tackled appropriately, or the system's damping performance will be severely hampered. Keeping this in view, an Interacting Multiple Model (IMM) infrastructure is employed to provide robust damping performance for such uncertainties. The IMM strategy utilizes the deviation of output error between actual and probable plants, through which weights are assigned to corresponding probable WADCs via the Bayesian framework. The simulations are performed on the nonlinear 4-machine, 11-bus system and the complex 16-machine, 68-bus system using MATLAB/Simulink platform. The results demonstrate that the proposed IMM-based WADC furnishes adequate damping to critical LFO modes for operating point and time delay uncertainties.


  • A Modal Transformation Approach to Design Reduced Order Functional Observer-Based WADC for Low-Frequency Oscillations

    by Abhineet Prakash, Kundan Kumar, S. K. Parida

    Low-frequency oscillations (LFOs) are one of the major concerns in modern power system; hence, these should be appropriately treated in order to achieve reliable operation. In this regard, we propose a novel wide-area damping controller (WADC) to dampen LFO modes effectively. The proposed WADC utilized thyristor controlled series compensator (TCSC) based flexible ac transmission system (FACTS) device through which supplementary input is provided. The selection of modal feedback signals for WADC design is carried out using coordinated modal transformation and linear quadratic regulator (LQR) approach. However, these signals are not accessible directly through the phasor measurement devices (PMDs). Hence, this paper utilizes a reduced-order functional observer to estimate the feedback signals using PMD data. The estimated feedback signals are further modulated by simple gains to improve the damping of critical LFO modes. The proposed methodology is validated on benchmark 4-machine 11-bus system and a more practical 25-machine, 105-bus system representing the complex Eastern Regional Grid (ERG) of India. The results obtained on these nonlinear systems show a significant improvement in damping of the critical LFOs leaving the other modes almost unaffected.


  • Design of a Reduced-Order WADC for Wind Turbine System-Integrated Power System

    by Abhineet Prakash, Priya Singh, Kundan Kumar, S. K. Parida

    The impact of wind turbine system (WTS) on power system stability is elaborately addressed in the literature. However, low-frequency oscillations, especially inter-area oscillations (IAOs) can be adversely affected due to their intermittent nature. This article proposes a wide-area damping controller (WADC) for WTS-integrated power system to damp IAOs effectively. The feedback signals (linear combination of the system states) are directly measurable from phasor measurement units. Therefore a reduced-order estimator is proposed instead of a full-order estimator to design the WADC. Furthermore, to select appropriate feedback signals for WADC design, combined geometric measure and modal decomposition techniques are utilized. The overall procedure to design the reduced-order WADC includes feedback signal selection, state feedback formulation using modal transformation approach, and reduced-order estimator design using loop transfer recovery procedure. Moreover, the WADC parameters are selected considering operating point uncertainties and variable time delays in feedback signals. Performance of the proposed WADC is validated on WTS-integrated 16-machine, 68-bus system. The simulation results show that the proposed WADC gives robust performance over broad operating scenarios.