Bertrand Estellon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bertrand Estellon has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Lionel Almeras
Aix Marseille Univ, SSA, RITMES
3 shared publications - Samuel Granjeaud
CRCM Integrative Bioinformatics Platform, Cancer Research Center of Marseille, CRCM, INSERM U1068, CNRS UMR7258, Aix-Marseille University U105, Marseille, France
3 shared publications - Bruno Pradines
Unité Parasitologie et Entomologie, Département Microbiologie et Maladies Infectieuses, Institut de Recherche Biomédicale des Armées, 13005 Marseille, France
2 shared publications - Floriant Saby
Unité Parasitologie et Entomologie, Département Microbiologie et Maladies Infectieuses, Institut de Recherche Biomédicale des Armées, 91220 Marseille, France
2 shared publications - François-Xavier Dupé
Laboratoire d’Informatique et Systèmes, Aix-Marseille University, CNRS, University de Toulon, 13013 Marseille, France
2 shared publications - Hervé Tissot-Dupont
IHU Méditerranée Infection, 13005 Marseille, France
2 shared publications
Latest Publications
- Open Access
- 6 June 2024
- Published by MDPI AG in Informatics
- Vol. 11 (2) , 39
MSProfileR: An Open-Source Software for Quality Control of Matrix-Assisted Laser Desorption Ionization–Time of Flight Spectra
In the early 2000s, matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) emerged as a performant and relevant tool for identifying micro-organisms. Since then, it has become practically essential for identifying bacteria in microbiological diagnostic laboratories. In the last decade, it was successfully applied for arthropod identification, allowing researchers to distinguish vectors from non-vectors of infectious diseases. However, identification failures are not rare, hampering its wide use. Failure is generally attributed either to the absence of respective counter species MS spectra in the database or to the insufficient quality of query MS spectra (i.e., lower intensity and diversity of MS peaks detected). To avoid matching errors due to non-compliant spectra, the development of a strategy for detecting and excluding outlier MS profiles became compulsory. To this end, we created MSProfileR, an R package leading to a bioinformatics tool through a simple installation, integrating a control quality system of MS spectra and an analysis pipeline including peak detection and MS spectra comparisons. MSProfileR can also add metadata concerning the sample that the spectra are derived from. MSProfileR has been developed in the R environment and offers a user-friendly web interface using the R Shiny framework. It is available on Microsoft Windows as a web browser application by simple navigation using the link of the package on Github v.3.10.0. MSProfileR is therefore accessible to non-computer specialists and is freely available to the scientific community. We evaluated MSProfileR using two datasets including exclusively MS spectra from arthropods. In addition to coherent sample classification, outlier MS spectra were detected in each dataset confirming the value of MSProfileR.
- 6 June 2024
- Published by MDPI AG in Informatics
- Vol. 11 (2) , 39
Open AccessMSProfileR: An Open-Source Software for Quality Control of Matrix-Assisted Laser Desorption Ionization–Time of Flight Spectra
In the early 2000s, matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) emerged as a performant and relevant tool for identifying micro-organisms. Since then, it has become practically essential for identifying bacteria in microbiological diagnostic laboratories. In the last decade, it was successfully applied for arthropod identification, allowing researchers to distinguish vectors from non-vectors of infectious diseases. However, identification failures are not rare, hampering its wide use. Failure is generally attributed either to the absence of respective counter species MS spectra in the database or to the insufficient quality of query MS spectra (i.e., lower intensity and diversity of MS peaks detected). To avoid matching errors due to non-compliant spectra, the development of a strategy for detecting and excluding outlier MS profiles became compulsory. To this end, we created MSProfileR, an R package leading to a bioinformatics tool through a simple installation, integrating a control quality system of MS spectra and an analysis pipeline including peak detection and MS spectra comparisons. MSProfileR can also add metadata concerning the sample that the spectra are derived from. MSProfileR has been developed in the R environment and offers a user-friendly web interface using the R Shiny framework. It is available on Microsoft Windows as a web browser application by simple navigation using the link of the package on Github v.3.10.0. MSProfileR is therefore accessible to non-computer specialists and is freely available to the scientific community. We evaluated MSProfileR using two datasets including exclusively MS spectra from arthropods. In addition to coherent sample classification, outlier MS spectra were detected in each dataset confirming the value of MSProfileR.
- Open Access
- 6 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 295
Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva
SARS-CoV-2 has caused a large outbreak since its emergence in December 2019. COVID-19 diagnosis became a priority so as to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n = 105) with healthy healthcare controls (n = 51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, support vector machine with linear kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2%, sensitivity = 85.1%, specificity = 85.3%, F1-Score = 85.1%). The application of the SVM-LK model on independent datasets confirmed its performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification had fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).
- 6 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 295
Open AccessExploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva
SARS-CoV-2 has caused a large outbreak since its emergence in December 2019. COVID-19 diagnosis became a priority so as to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n = 105) with healthy healthcare controls (n = 51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, support vector machine with linear kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2%, sensitivity = 85.1%, specificity = 85.3%, F1-Score = 85.1%). The application of the SVM-LK model on independent datasets confirmed its performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification had fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).
- Open Access
- 24 September 2021
- Published by MDPI AG in Preprints.org
Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva
SARS-CoV-2 caused a large outbreak since its emergence in December 2019. The COVID-19 diagnosis became a priority to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n=105) with healthy healthcare controls (n=51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, Support Vector Machine with Linear Kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2 %, sensitivity = 85.1 %, specificity = 85.3 %, F1-Score = 85.1 %). The application of the SVM-LK model on independent datasets confirmed it performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).
- 24 September 2021
- Published by MDPI AG in Preprints.org
Open AccessExploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva
SARS-CoV-2 caused a large outbreak since its emergence in December 2019. The COVID-19 diagnosis became a priority to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n=105) with healthy healthcare controls (n=51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, Support Vector Machine with Linear Kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2 %, sensitivity = 85.1 %, specificity = 85.3 %, F1-Score = 85.1 %). The application of the SVM-LK model on independent datasets confirmed it performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).