Giuseppe Mauro Bucolo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giuseppe Mauro Bucolo has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Tommaso D'ANgelo
Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital “Policlinico G. Martino”, Via Consolare Valeria 1, 98100 Messina, Italy
14 shared publications - Christian Booz
Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
11 shared publications - Thomas Joseph Vogl
Medical University of Vienna, Center for Cancer Research
10 shared publications - Ibrahim Yel
Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
8 shared publications - Vitali Koch
Clinic for Radiology and Nuclear Medicine, University Hospital, Goethe University Frankfurt, 60590 Frankfurt am Main, Germany
8 shared publications - Alfredo Blandino
Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital “AOU G. Martino”, 98124 Messina, Italy
6 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (20) , 7870
CT-Derived Adipose Tissue Biomarkers in Coronary and Carotid Atherosclerosis: A Systematic Review of Dual-Energy, Spectral, and Photon-Counting CT
Background/Objectives: Advanced Computed Tomography (CT) enables multiparametric characterization of local perivascular and regional or systemic adipose tissue, potentially providing markers of vascular inflammation and cardiometabolic remodeling beyond conventional assessment of the vessel lumen and plaque. However, evidence remains fragmented across CT technologies, adipose depots and vascular territories. This systematic review evaluated human studies of adipose-tissue biomarkers derived from dual-layer spectral-detector CT (DLSCT), dual-source dual-energy CT (DS-DECT), rapid kVp-switching dual-energy CT (rsDECT), and photon-counting CT (PCCT) in coronary and carotid atherosclerosis. Methods: PubMed and Scopus were systematically searched for English-language human studies published from 1 January 2020, to 13 September 2026, supplemented by backward and forward citation searching of eligible studies and reference-list screening of relevant reviews. Two reviewers independently performed study selection and risk-of-bias assessment. Because of clinical, technical, and methodological heterogeneity, findings were synthesized narratively without meta-analysis. Results: Nineteen reports representing 15 likely independent study clusters met the inclusion criteria. DLSCT-derived pericoronary adipose-tissue attenuation; DECT-derived carotid perivascular adipose-tissue parameters; PCCT-derived adipose attenuation, volume, and radiomic features; and spectral measures of hepatic or visceral adiposity were associated with coronary artery disease, stenosis severity, high-risk plaque features, coronary calcification, or symptomatic carotid disease. Reported discrimination estimates were heterogeneous across populations, endpoints, and model structures and were predominantly derived from unvalidated development samples. Conclusions: Advanced CT-derived adipose-tissue biomarkers may complement conventional assessment of the vessel lumen and plaque by characterizing local vessel–adipose interactions and systemic cardiometabolic phenotype. However, current measurements are protocol- and platform-dependent, and clinical utility has not been established. Standardized measurement pipelines, biological validation, and prospective multicenter studies are required before routine clinical implementation.
- 12 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (20) , 7870
Open AccessCT-Derived Adipose Tissue Biomarkers in Coronary and Carotid Atherosclerosis: A Systematic Review of Dual-Energy, Spectral, and Photon-Counting CT
Background/Objectives: Advanced Computed Tomography (CT) enables multiparametric characterization of local perivascular and regional or systemic adipose tissue, potentially providing markers of vascular inflammation and cardiometabolic remodeling beyond conventional assessment of the vessel lumen and plaque. However, evidence remains fragmented across CT technologies, adipose depots and vascular territories. This systematic review evaluated human studies of adipose-tissue biomarkers derived from dual-layer spectral-detector CT (DLSCT), dual-source dual-energy CT (DS-DECT), rapid kVp-switching dual-energy CT (rsDECT), and photon-counting CT (PCCT) in coronary and carotid atherosclerosis. Methods: PubMed and Scopus were systematically searched for English-language human studies published from 1 January 2020, to 13 September 2026, supplemented by backward and forward citation searching of eligible studies and reference-list screening of relevant reviews. Two reviewers independently performed study selection and risk-of-bias assessment. Because of clinical, technical, and methodological heterogeneity, findings were synthesized narratively without meta-analysis. Results: Nineteen reports representing 15 likely independent study clusters met the inclusion criteria. DLSCT-derived pericoronary adipose-tissue attenuation; DECT-derived carotid perivascular adipose-tissue parameters; PCCT-derived adipose attenuation, volume, and radiomic features; and spectral measures of hepatic or visceral adiposity were associated with coronary artery disease, stenosis severity, high-risk plaque features, coronary calcification, or symptomatic carotid disease. Reported discrimination estimates were heterogeneous across populations, endpoints, and model structures and were predominantly derived from unvalidated development samples. Conclusions: Advanced CT-derived adipose-tissue biomarkers may complement conventional assessment of the vessel lumen and plaque by characterizing local vessel–adipose interactions and systemic cardiometabolic phenotype. However, current measurements are protocol- and platform-dependent, and clinical utility has not been established. Standardized measurement pipelines, biological validation, and prospective multicenter studies are required before routine clinical implementation.
- Open Access
- 28 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3145
Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40–55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.
- 28 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3145
Open AccessDual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging
Background/Objectives: This study aimed to investigate the impact of low-energy virtual monoenergetic imaging (VMI) on quantitative and qualitative image characteristics, as well as its effect on the diagnostic assessability of thoracic arteries in photon-counting computed tomography angiography (CTA). Methods: We retrospectively evaluated 125 patients who underwent dual-source photon-counting CTA scans of thoracic arteries. We reconstructed standard CT images at 120 kV and VMI series at 15 keV intervals, ranging from 40 to 100 keV, and conducted quantitative and qualitative image analyses. For quantitative analysis, we assessed vascular CT numbers and contrast-to-noise ratio (CNR). For qualitative evaluation, three board-certified radiologists independently rated image quality, vascular contrast, and diagnostic assessability of the thoracic arteries using a five-point scale. Results: Quantitative image analysis revealed that 40 keV VMI reconstructions exhibited the highest mean CT value (HU: 1205 ± 286) and CNR (29.22 ± 9.13), followed by the 55 keV series (HU: 679 ± 161, CNR: 22.54 ± 7.36), significantly improved compared to higher keV levels and the standard 120 kV CT series (p < 0.001). Qualitative analysis showed the highest rating scores for 55 keV reconstructions, significantly higher than those of VMI series at higher energy levels and the standard 120 kV series (p < 0.001). Conclusions: VMI reconstructions at low energy levels (40–55 keV) significantly enhance vascular CTvalue and CNR, offering superior image quality and diagnostic assessability for thoracic arteries compared to standard CT series in photon-counting CTA.
- Open Access
- 28 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2774
Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT
Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40–50 keV and 70–80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.
- 28 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2774
Open AccessPlaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT
Objectives: The objective of this study was to evaluate the impact of virtual monoenergetic image (VMI) reconstructions derived from photon-counting computed tomography (PCCT) on the assessment of carotid arteries, with a focus on optimizing keV selection based on plaque composition. Methods: This retrospective study included 111 patients (mean age 80 ± 7.5 years; 64 men; 47 women) with carotid sclerosis who underwent PCCT between April 2022 and February 2023. One lesion was analyzed per patient, each containing both calcified and non-calcified components. Quantitative measurements were performed in calcified plaque across energy levels from 40 to 120 keV and comprised attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), corrected image noise (CIN) and artifact index (AIX). Two radiologists independently rated image quality, artifacts, and diagnostic assessability of both components using five-point scales. Results: Attenuation and CNR were highest at 40 to 50 keV, where CIN and AIX were also greatest. SNR followed a U-shaped course, lowest at 90 keV and highest at 110 to 120 keV, where intraluminal attenuation was too low for reliable luminal delineation. Reader ratings were highest at 40 to 50 keV for non-calcified components and at 70 to 80 keV for calcified plaque, with good interobserver agreement throughout (κ 0.74 to 0.92). After correction for multiple testing, adjacent energy levels were frequently indistinguishable. Conclusions: Optimal PCCT VMI energy levels depend on plaque composition. The findings support implementing standardized protocols with automatic dual-range reconstructions (40–50 keV and 70–80 keV) to enable efficient, individualized carotid plaque assessment in clinical practice.
- 19 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2232-2240
Spectral CT for non-invasive evaluation of bladder cancer grade
Objective To investigate the potential role of dual-energy spectral computer tomography (CT) quantitative parameters in the definition of bladder cancer (BCa) pathological grading. Methods This retrospective study evaluated the use of spectral CT imaging features for BCa. From 2021 to 2023, 63 patients with histologically-confirmed BCa diagnosis were examined at our Institution. The patients were pathologically divided, following international guidelines, into two groups: low-grade (n = 24) and high-grade urothelial carcinoma group (n = 39). The iodine concentrations (IC), the normalized iodine concentrations (NIC), and the slope of the spectrum curve (SLOPE) were calculated along with the measure of each lesion CT value on the monochromatic image from 40 to 120 keV. The diagnostic performance was assessed by Receiver operator characteristic curve (ROC) analysis. Results The high-grade group showed significantly higher mean values of IC, SLOPE, and HU in 40 KeV monoenergetic images (VMI40 HU). AUC values for NIC, SLOPE, IC, and VMI40 HU were 0,677, 0,745, 0,745, and 0,755 respectively. In multivariate logistic regression models with backward stepwise, including all quantitative parameters, only VMI40 HU remained statistically significant to correlate with high-grade tumors. Conclusion Preliminary data shows that quantitative parameters of dual-energy spectral CT can be helpful to characterize low-grade and high-grade urothelial bladder tumors. The prediction of high-grade BCa with non-invasive methods (e.g. dlCT) can aid in early detection of muscle-invasive and worse prognostic tumors that need more aggressive and timely treatments, personalizing the management on the risk of recurrence.
- 19 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2232-2240
Spectral CT for non-invasive evaluation of bladder cancer grade
Objective To investigate the potential role of dual-energy spectral computer tomography (CT) quantitative parameters in the definition of bladder cancer (BCa) pathological grading. Methods This retrospective study evaluated the use of spectral CT imaging features for BCa. From 2021 to 2023, 63 patients with histologically-confirmed BCa diagnosis were examined at our Institution. The patients were pathologically divided, following international guidelines, into two groups: low-grade (n = 24) and high-grade urothelial carcinoma group (n = 39). The iodine concentrations (IC), the normalized iodine concentrations (NIC), and the slope of the spectrum curve (SLOPE) were calculated along with the measure of each lesion CT value on the monochromatic image from 40 to 120 keV. The diagnostic performance was assessed by Receiver operator characteristic curve (ROC) analysis. Results The high-grade group showed significantly higher mean values of IC, SLOPE, and HU in 40 KeV monoenergetic images (VMI40 HU). AUC values for NIC, SLOPE, IC, and VMI40 HU were 0,677, 0,745, 0,745, and 0,755 respectively. In multivariate logistic regression models with backward stepwise, including all quantitative parameters, only VMI40 HU remained statistically significant to correlate with high-grade tumors. Conclusion Preliminary data shows that quantitative parameters of dual-energy spectral CT can be helpful to characterize low-grade and high-grade urothelial bladder tumors. The prediction of high-grade BCa with non-invasive methods (e.g. dlCT) can aid in early detection of muscle-invasive and worse prognostic tumors that need more aggressive and timely treatments, personalizing the management on the risk of recurrence.
- Open Access
- 26 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (5) , 496
Dual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
Background: Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. Methods: Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). Results: Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). Conclusion: physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.
- 26 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (5) , 496
Open AccessDual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
Background: Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. Methods: Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). Results: Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). Conclusion: physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.
- Open Access
- 21 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (5) , 466
Dual-Energy CT Material Decomposition: The Value in the Detection of Lymph Node Metastasis from Breast Cancer
Purpose: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. Materials and Methods: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. Results: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p < 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. Conclusions: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.
- 21 February 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (5) , 466
Open AccessDual-Energy CT Material Decomposition: The Value in the Detection of Lymph Node Metastasis from Breast Cancer
Purpose: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. Materials and Methods: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. Results: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p < 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. Conclusions: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.
- Open Access
- 5 February 2024
- Published by MDPI AG in Preprints.org
Dual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
Purpose Despite a considerable amount of literature on dual-energy-CT(DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. Material and Methods: Consecutive venous DECT scans of head and neck were reviewed, and unremarkable exams were included (n=617). 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male [n=403] vs female [n=214]; young [n=207] vs middle-aged [n=206] vs old [n=204]; normal weight [n=314] vs overweight [n=196] vs obese [n=107]]). Results: Overall mean iodine uptake values ranged between 0.5 and 9.4mg/ml. Women showed higher iodine concentration in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for tongue and palatine tonsils were lower compared to younger subjects (p0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with higher BMI (p0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with higher BMI (p0.04). Conclusion: Physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in clinical routine of head and neck DECT.
- 5 February 2024
- Published by MDPI AG in Preprints.org
Open AccessDual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
Purpose Despite a considerable amount of literature on dual-energy-CT(DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. Material and Methods: Consecutive venous DECT scans of head and neck were reviewed, and unremarkable exams were included (n=617). 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male [n=403] vs female [n=214]; young [n=207] vs middle-aged [n=206] vs old [n=204]; normal weight [n=314] vs overweight [n=196] vs obese [n=107]]). Results: Overall mean iodine uptake values ranged between 0.5 and 9.4mg/ml. Women showed higher iodine concentration in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for tongue and palatine tonsils were lower compared to younger subjects (p0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with higher BMI (p0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with higher BMI (p0.04). Conclusion: Physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in clinical routine of head and neck DECT.
- Open Access
- 14 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (16) , 2675
Improved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72–0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.
- 14 August 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (16) , 2675
Open AccessImproved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72–0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.
- Open Access
- 17 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (14) , 4718
Virtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.
- 17 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (14) , 4718
Open AccessVirtual Non-Contrast Spectral CT in Renal Masses: Is It Time to Discard Conventional Unenhanced Phase?
Dual-layer Dual-Energy CT (dl-DECT) allows one to create virtual non-contrast (VNC) reconstructions from contrast-enhanced CT scans, with a consequent decrease of the radiation dose. This study aims to assess the reliability of VNC for the diagnostic evaluation of renal masses in comparison with true non-contrast (TNC) images. The study cohort included 100 renal masses in 40 patients who underwent dl-DECT between June and December 2021. Attenuation values and standard deviations were assessed through the drawing of regions of interest on TNC and VNC images reconstructed from corticomedullary and nephrographic phases. A Wilcoxon signed-rank test was performed in order to assess equivalence of data and Spearman’s Rho correlation coefficient to evaluate correlations between each parameter. The diagnostic accuracy of VNC was estimated through the performance of receiver operating characteristic (ROC) curve analysis. Differences between attenuation values were, respectively, 74%, 18%, 5% and 3% (TNC-VNCcort), and 74%, 15%, 9% and 2% (TNC-VNCneph). The Wilcoxon signed-rank test demonstrated the equivalence of attenuation values between the TNC and VNC images. The diagnostic performance of VNC images in the depiction of kidney simple cysts remains high compared to TNC (VNCcort-AUC: 0.896; VNCneph-AUC: 0.901, TNC-AUC: 0.903). In conclusion, quantitative analysis of attenuation values showed a strong agreement between VNC and TNC images in the evaluation of renal masses.
- Open Access
- 18 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1790
Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus
Background: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. Purpose: To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. Materials and Methods: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. Results: Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). Conclusions: DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.
- 18 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1790
Open AccessVirtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus
Background: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. Purpose: To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. Materials and Methods: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. Results: Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). Conclusions: DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.