Dual-Energy CT Iodine Uptake of Head and Neck: Definition of Reference Values in a Big Data Cohort
Authors:
- Ibrahim YelIYIbrahim Yel
- Giuseppe Mauro BucoloGBGiuseppe Mauro Bucolo
- Scherwin MahmoudiSMScherwin Mahmoudi
- Vitali KochVKVitali Koch
- Aynur GökdumanAGAynur Gökduman
- Tommaso D′AngeloTDTommaso D′Angelo
- Leon David GrünewaldLGLeon David Grünewald
- Mirela DimitrovaMDMirela Dimitrova
- Katrin EichlerKEKatrin Eichler
- Thomas J. VoglThomas J. Vogl
- Christian BoozCBChristian Booz
Open Access
- 26 February 2024
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 14 (5) , 496
Abstract
Background: Despite a considerable amount of literature on dual-energy CT (DECT) iodine uptake of the head and neck, the physiologic iodine uptake of this region has not been defined yet. This study aims to establish reference values for the iodine uptake of healthy organs to facilitate clinical application. Methods: Consecutive venous DECT scans of the head and neck were reviewed, and unremarkable exams were included (n = 617). A total of 35 region of interest measurements were performed in 16 anatomical regions. Iodine uptake was compared among different organs/tissues and subgroup analysis was performed (male (n = 403) vs. female (n = 214); young (n = 207) vs. middle-aged (n = 206) vs. old (n = 204); and normal weight (n = 314) vs. overweight (n = 196) vs. obese (n = 107)). Results: Overall mean iodine uptake values ranged between 0.5 and 9.4 mg/mL. Women showed higher iodine concentrations in the cervical vessels and higher uptake for the parotid gland, masseter muscle, submandibular glands, sublingual glands, palatine tonsils, tongue body, thyroid gland, and the sternocleidomastoid muscle than men (p ≤ 0.04). With increasing age, intravascular iodine concentrations increased as well as iodine uptake for cerebellum and thyroid gland, while values for the tongue and palatine tonsils were lower compared to younger subjects (p ≤ 0.03). Iodine concentrations for parotid glands and sternocleidomastoid muscles decreased with a higher BMI (p ≤ 0.004), while normal-weighted patients showed higher iodine values inside the jugular veins, other cervical glands, and tonsils versus patients with a higher BMI (p ≤ 0.04). Conclusion: physiologic iodine uptake values of cervical organs and tissues show gender-, age-, and BMI-related differences, which should be considered in the clinical routine of head and neck DECT.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Dual-energy CT in early acute pancreatitis: improved detection using iodine quantificationEuropean Radiology, 2018
- Precision and reliability of liver iodine quantification from spectral detector CT: evidence from phantom and patient dataEuropean Radiology, 2018
- Metastatic and non-metastatic lymph nodes: quantification and different distribution of iodine uptake assessed by dual-energy CTEuropean Radiology, 2017
- Dual-Energy CT in Head and Neck ImagingCurrent Radiology Reports, 2017
- Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CTEuropean Radiology, 2017
- Quantitative iodine content threshold for discrimination of renal cell carcinomas using rapid kV-switching dual-energy CTAbdominal Radiology, 2016
- Differentiation of malignant cervical lymphadenopathy by dual-energy CT: a preliminary analysisScientific Reports, 2016
- Dual-energy CT of pancreatic adenocarcinoma: reproducibility of primary tumor measurements and assessment of tumor conspicuity and margin sharpnessAbdominal Radiology, 2016
- Evaluation of dual energy spectral CT in differentiating metastatic from non-metastatic lymph nodes in rectal cancer: Initial experienceEuropean Journal of Radiology, 2015
- Pretreatment with Corticosteroids to Alleviate Reactions to Intravenous Contrast MaterialNew England Journal of Medicine, 1987