MJMiaomiao Ji

Miaomiao Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miaomiao Ji has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Detachable, Reusable, and Versatile Acoustic Tweezer Manipulation Platform for Biochemical Analysis and Detection Systems

    by Yukai Liu, Miaomiao Ji, Yichi Zhang, Xiaojun Qiao, Nanxin Yu, Chenxi Ding, Lingxiao Yang, Rui Feng, Xiujian Chou, Wenping Geng

    Multifunctional, integrated, and reusable operating platforms are highly sought after in biochemical analysis and detection systems. In this study, we demonstrated a novel detachable, reusable acoustic tweezer manipulation platform that is flexible and versatile. The free interchangeability of different detachable microchannel devices on the acoustic tweezer platform was achieved by adding a waveguide layer (glass) and a coupling layer (polydimethylsiloxane (PDMS) polymer film). We designed and demonstrated the detachable multifunctional acoustic tweezer platform with three cell manipulation capabilities. In Demo I, the detachable acoustic tweezer platform is demonstrated to have the capability for parallel processing and enrichment of the sample. In Demo II, the detachable acoustic tweezer platform with capability for precise cell alignment is demonstrated. In Demo III, it was demonstrated that the detachable acoustic tweezer platform has the capability for the separation and purification of cells. Through experiments, our acoustic tweezer platform has good acoustic retention ability, reusability, and stability. More capabilities can be expanded in the future. It provides a simple, economical, and multifunctional reusable operating platform solution for biochemical analysis and detection systems.


  • Open Access

    A Perturbed Asymmetrical Y-TypeSheathless Chip for Particle Control Based on Adjustable Tilted-Angle Traveling Surface Acoustic Waves (ataTSAWs)

    by Junping Duan, Miaomiao Ji, Binzhen Zhang

    The precise control of target particles (20 µm) at different inclination angles θi is achieved by combining a perturbed asymmetric sheathless Y-type microchannel and a digital transducer (IDT). The offset single-row micropillar array with the buffer area can not only concentrate large and small particles in a fixed region of the flow channel, but also avoid the large deflection of some small particles at the end of the array. The addition of the buffer area can effectively improve the separation purity of the chip. By exploring the manufacturing process of the microchannel substrate, an adjustable tilted-angle scheme is proposed. The use of ataTSAW makes the acoustic field area in the microchannel have no corner effect region. Through experiments, when the signal source frequency was 33.6 MHz, and the flow rate was 20 µL/min, our designed chip could capture 20 µm particles when θi = 5°. The deflection of 20 µm particles can be realized when θi = 15°–45°. The precise dynamic separation of 20 µm particles can be achieved when θi = 25°–45°, and the separation purity and efficiency were 97% and 100%, respectively.


  • Open Access

    Enhanced Detection in Droplet Microfluidics by Acoustic Vortex Modulation of Particle Rings and Particle Clusters via Asymmetric Propagation of Surface Acoustic Waves

    by Yukai Liu, Miaomiao Ji, Nanxin Yu, Caiqin Zhao, Gang Xue, Wenxiao Fu, Xiaojun Qiao, Yichi Zhang, Xiujian Chou, Wenping Geng

    As a basis for biometric and chemical analysis, issues of how to dilute or concentrate substances such as particles or cells to specific concentrations have long been of interest to researchers. In this study, travelling surface acoustic wave (TSAW)-based devices with three frequencies (99.1, 48.8, 20.4 MHz) have been used to capture the suspended Polystyrene (PS) microspheres of various sizes (5, 20, 40 μm) in sessile droplets, which are controlled by acoustic field-induced fluid vortex (acoustic vortex) and aggregate into clusters or rings with particles. These phenomena can be explained by the interaction of three forces, which are drag force caused by ASF, ARF caused by Leaky-SAW and varying centrifugal force. Eventually, a novel approach of free transition between the particle ring and cluster was approached via modulating the acoustic amplitude of TSAW. By this method, multilayer particles agglomerate with 20 μm wrapped around 40 μm and 20 μm wrapped around 5 μm can be obtained, which provides the possibility to dilute or concentrate the particles to a specific concentration.


  • Open Access

    A Novel Perturbed Spiral Sheathless Chip for Particle Separation Based on Traveling Surface Acoustic Waves (TSAW)

    by Miaomiao Ji, Yukai Liu, Junping Duan, Wenxuan Zang, Yongsheng Wang, Zeng Qu, Binzhen Zhang

    The combination of the new perturbed spiral channel and a slanted gold interfingered transducer (IDT) is designed to achieve precise dynamic separation of target particles (20 μm). The offset micropillar array solves the defect that the high-width flow (avoiding the occurrence of channel blockage) channel cannot realize the focusing of small particles (5 μm, 10 μm). The relationship between the maximum design gap of the micropillar (Smax) and the particle radius (a) is given: Smax = 4a, which not only ensures that small particles will not pass through the micropillar gap, but also is compatible with the appropriate flow rates. A non-offset micropillar array was used to remove 20 μm particles in the corner area. The innovation of a spiral channel structure greatly improves the separation efficiency and purity of the separation chip. The separation chip designed by us achieves deflection separation of 20 μm particles at 24.95–41.58 MHz (κ = 1.09–1.81), at a flow rate of 1.2 mL per hour. When f = 33.7 MHz (κ = 1.47), the transverse migration distance of 20 μm particles is the smallest, and the separation purity and efficiency are as high as 92% and 100%, respectively.


  • Open Access

    Continuous Particle Separation Driven by 3D Ag-PDMS Electrodes with Dielectric Electrophoretic Force Coupled with Inertia Force

    by Xiaohong Li, Junping Duan, Zeng Qu, Jiayun Wang, Miaomiao Ji, Binzhen Zhang

    Cell separation has become @important in biological and medical applications. Dielectrophoresis (DEP) is widely used due to the advantages it offers, such as the lack of a requirement for biological markers and the fact that it involves no damage to cells or particles. This study aimed to report a novel approach combining 3D sidewall electrodes and contraction/expansion (CEA) structures to separate three kinds of particles with different sizes or dielectric properties continuously. The separation was achieved through the interaction between electrophoretic forces and inertia forces. The CEA channel was capable of sorting particles with different sizes due to inertial forces, and also enhanced the nonuniformity of the electric field. The 3D electrodes generated a non-uniform electric field at the same height as the channels, which increased the action range of the DEP force. Finite element simulations using the commercial software, COMSOL Multiphysics 5.4, were performed to determine the flow field distributions, electric field distributions, and particle trajectories. The separation experiments were assessed by separating 4 µm polystyrene (PS) particles from 20 µm PS particles at different flow rates by experiencing positive and negative DEP. Subsequently, the sorting performances of the 4 µm PS particles, 20 µm PS particles, and 4 µm silica particles with different solution conductivities were observed. Both the numerical simulations and the practical particle separation displayed high separating efficiency (separation of 4 µm PS particles, 94.2%; separation of 20 µm PS particles, 92.1%; separation of 4 µm Silica particles, 95.3%). The proposed approach is expected to open a new approach to cell sorting and separating.