YLYukai Liu

Yukai Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yukai Liu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A hollow-core fiber based optofluidic chip for rapid immunofluorescence detection with simultaneous enhancement of sensitivity and enrichment efficiency

    by Xiao Ren, Tian Wen, Yukai Liu, Xiaoxian Liu, Feng Lin, Zhenyong Dong, Hao Wang, Lunbiao Cui, Yan-Qing Lu, Guanghui Wang

    Although conventional ELISA is highly sensitive, its intricate workflow, significant background interference and dependence on laboratory infrastructure severely restrict its use for on-site testing. Lateral-flow assays (LFAs) are simple and portable, yet the numerous manual steps and inability to deliver truly quantitative results lead to inadequate sensitivity and poor reliability, failing to meet clinical requirements. Therefore, there is an urgent need for an immunological method that is both highly sensitive and simple to perform. Here, we propose an all-fiber optofluidic immunosensor based on a hollow-core fiber (HCF) that integrates the entire assay onto a single microfluidic chip. A standard fiber is inserted into the HCF for direct light coupling, and the gap between the two fibers serves as the sample inlet, eliminating external pumps and tubing. The inner wall of the HCF can be functionalized, providing an extremely high surface-to-volume ratio; the long, confined microchannel shortens analyte diffusion distances and prolongs residence time, markedly improving antibody-capture efficiency and reducing enrichment duration. Coaxial propagation of both light and the sample inside the HCF strengthens light–matter interaction and enhances fluorescence collection efficiency. Without any pre-incubation, quantitative detection of influenza A antigen is completed within 10 min, achieving a limit of detection of 2.41 pg mL−1. The limit of detection and assay time of this method are both lower than those of many conventional lateral flow immunoassay cases, and the method exhibits excellent reproducibility and specificity. The proposed HCF microfluidic chip successfully breaks the conventional sensitivity-versus-speed trade-off, offering a promising solution for rapid point-of-care clinical diagnostics.

  • Open Access

    Deep Learning‐Assisted Rapid Bacterial Classification Based on Raman Spectroscopy of Bacteria Lysed by Acoustically Driven Fiber‐Tip Vibration

    by Yukai Liu, Miaomiao Ji, Xiao Ren, Zhenyong Dong, Tian Wen, Qingyue Dong, Ho‐Pui Ho, Lunbiao Cui, Yanqing Lu, Guanghui Wang

    Rapid and accurate identification of bacterial pathogens is critical for effective clinical decision‐making and combating antibiotic resistance. Surface‐enhanced Raman spectroscopy (SERS) combined with machine learning (ML) offers a powerful method for rapid, label‐free bacterial identification. Conventional methods rely on surface molecular structures for identification, yet the richer and unique spectral information from intracellular biomolecules is often masked by the bacterial envelope, limiting classification accuracy. Here, a novel bacterial classification method is demonstrated by introducing acoustofluidic lysis based on the vibrating fiber‐tip, combined with Raman spectroscopy and deep learning. The fiber‐tip oscillates in a torsional mode, generating a controlled single‐vortex within a capillary to concentrate bacteria in high‐shear regions, enhancing lysis efficiency. This process effectively exposes intracellular components such as nucleic acids, proteins, and lipids, significantly enhancing the expression of features in bacterial Raman spectra, improving both spectral resolution and information richness. A residual neural network (ResNet) model is further employed for automated classification, achieving 98.9% accuracy across seven bacterial samples, surpassing traditional classifiers like random forests. The clinical validation experiments highlight the method's potential for real‐world applications, enabling direct, on‐site detection of clinical samples and facilitating rapid diagnostics, thus offering a promising advancement in pathogen identification.


  • 3D-printed acoustic metasurface with encapsulated micro-air-bubbles for frequency-selective manipulation

    by Miaomiao Ji, Yukai Liu, Zheng Zhang, Rui Xu, Fanyun Pan, Ya Zhang, Rouyu Su, Minghui Lu, Xiujuan Zhang, Guanghui Wang

    A low-frequency acoustic metasurface with PDMS-stabilized microbubbles achieves stable vibration modes, precise control over micro-object aggregation, rotation, separation, and selective trajectory manipulation through frequency-tuned excitation.


  • Open Access

    A Novel Detachable, Reusable, and Versatile Acoustic Tweezer Manipulation Platform for Biochemical Analysis and Detection Systems

    by Yukai Liu, Miaomiao Ji, Yichi Zhang, Xiaojun Qiao, Nanxin Yu, Chenxi Ding, Lingxiao Yang, Rui Feng, Xiujian Chou, Wenping Geng

    Multifunctional, integrated, and reusable operating platforms are highly sought after in biochemical analysis and detection systems. In this study, we demonstrated a novel detachable, reusable acoustic tweezer manipulation platform that is flexible and versatile. The free interchangeability of different detachable microchannel devices on the acoustic tweezer platform was achieved by adding a waveguide layer (glass) and a coupling layer (polydimethylsiloxane (PDMS) polymer film). We designed and demonstrated the detachable multifunctional acoustic tweezer platform with three cell manipulation capabilities. In Demo I, the detachable acoustic tweezer platform is demonstrated to have the capability for parallel processing and enrichment of the sample. In Demo II, the detachable acoustic tweezer platform with capability for precise cell alignment is demonstrated. In Demo III, it was demonstrated that the detachable acoustic tweezer platform has the capability for the separation and purification of cells. Through experiments, our acoustic tweezer platform has good acoustic retention ability, reusability, and stability. More capabilities can be expanded in the future. It provides a simple, economical, and multifunctional reusable operating platform solution for biochemical analysis and detection systems.


  • Open Access

    Enhanced Detection in Droplet Microfluidics by Acoustic Vortex Modulation of Particle Rings and Particle Clusters via Asymmetric Propagation of Surface Acoustic Waves

    by Yukai Liu, Miaomiao Ji, Nanxin Yu, Caiqin Zhao, Gang Xue, Wenxiao Fu, Xiaojun Qiao, Yichi Zhang, Xiujian Chou, Wenping Geng

    As a basis for biometric and chemical analysis, issues of how to dilute or concentrate substances such as particles or cells to specific concentrations have long been of interest to researchers. In this study, travelling surface acoustic wave (TSAW)-based devices with three frequencies (99.1, 48.8, 20.4 MHz) have been used to capture the suspended Polystyrene (PS) microspheres of various sizes (5, 20, 40 μm) in sessile droplets, which are controlled by acoustic field-induced fluid vortex (acoustic vortex) and aggregate into clusters or rings with particles. These phenomena can be explained by the interaction of three forces, which are drag force caused by ASF, ARF caused by Leaky-SAW and varying centrifugal force. Eventually, a novel approach of free transition between the particle ring and cluster was approached via modulating the acoustic amplitude of TSAW. By this method, multilayer particles agglomerate with 20 μm wrapped around 40 μm and 20 μm wrapped around 5 μm can be obtained, which provides the possibility to dilute or concentrate the particles to a specific concentration.


  • Open Access

    A Novel Perturbed Spiral Sheathless Chip for Particle Separation Based on Traveling Surface Acoustic Waves (TSAW)

    by Miaomiao Ji, Yukai Liu, Junping Duan, Wenxuan Zang, Yongsheng Wang, Zeng Qu, Binzhen Zhang

    The combination of the new perturbed spiral channel and a slanted gold interfingered transducer (IDT) is designed to achieve precise dynamic separation of target particles (20 μm). The offset micropillar array solves the defect that the high-width flow (avoiding the occurrence of channel blockage) channel cannot realize the focusing of small particles (5 μm, 10 μm). The relationship between the maximum design gap of the micropillar (Smax) and the particle radius (a) is given: Smax = 4a, which not only ensures that small particles will not pass through the micropillar gap, but also is compatible with the appropriate flow rates. A non-offset micropillar array was used to remove 20 μm particles in the corner area. The innovation of a spiral channel structure greatly improves the separation efficiency and purity of the separation chip. The separation chip designed by us achieves deflection separation of 20 μm particles at 24.95–41.58 MHz (κ = 1.09–1.81), at a flow rate of 1.2 mL per hour. When f = 33.7 MHz (κ = 1.47), the transverse migration distance of 20 μm particles is the smallest, and the separation purity and efficiency are as high as 92% and 100%, respectively.