Lidija Matjacic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lidija Matjacic has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Alexander Pirkl
IONTOF GmbH Münster Germany
1 shared publication- Andrea Ciavatti
Department of Physics and Astronomy, University of Bologna, Bologna, Italy
1 shared publication - Andrew J. Parnell
School of Mathematical and Physical Sciences, University of Sheffield, Sheffield, UK
1 shared publication - Andrew Nisbet
Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
1 shared publication - Anushanth Karalasingam
Institute for Materials and Processes, University of Edinburgh, United Kingdom
1 shared publication - Arvydas Ruseckas
Organic Semiconductor Centre, SUPA, School of Physics and Astronomy, University of St. Andrews, St. Andrews, KY16 9SS, UK
1 shared publication
Latest Publications
- Open Access
- 2 November 2023
- Published by Wiley in Advanced Science
- Vol. 10 (35) , e2304261
Tissue Equivalent Curved Organic X‐ray Detectors Utilizing High Atomic Number Polythiophene Analogues
Organic semiconductors are a promising material candidate for X‐ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X‐ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high‐sensitivity performance for X‐ray detectors based on organic semiconductors modified with high –Z heteroatoms. X‐ray detectors are fabricated with p‐type organic semiconductors containing selenium heteroatoms (poly(3‐hexyl)selenophene (P3HSe)) in blends with an n‐type fullerene derivative ([6,6]‐Phenyl C71 butyric acid methyl ester (PC70BM). When characterized under 70, 100, 150, and 220 kVp X‐ray radiation, these heteroatom‐containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy−1 cm−2 with respect to the bismuth oxide (Bi2O3) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron‐hole pairs, better charge transfer, and charge transport characteristics in heteroatom‐incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X‐ray detectors that can be curved to a radius as low as 2 mm with low deviation in X‐ray response under 100 repeated bending cycles while maintaining an industry‐standard ultra‐low dark current of 0.03 ± 0.01 pA mm−2.
- 2 November 2023
- Published by Wiley in Advanced Science
- Vol. 10 (35) , e2304261
Open AccessTissue Equivalent Curved Organic X‐ray Detectors Utilizing High Atomic Number Polythiophene Analogues
Organic semiconductors are a promising material candidate for X‐ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X‐ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high‐sensitivity performance for X‐ray detectors based on organic semiconductors modified with high –Z heteroatoms. X‐ray detectors are fabricated with p‐type organic semiconductors containing selenium heteroatoms (poly(3‐hexyl)selenophene (P3HSe)) in blends with an n‐type fullerene derivative ([6,6]‐Phenyl C71 butyric acid methyl ester (PC70BM). When characterized under 70, 100, 150, and 220 kVp X‐ray radiation, these heteroatom‐containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy−1 cm−2 with respect to the bismuth oxide (Bi2O3) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron‐hole pairs, better charge transfer, and charge transport characteristics in heteroatom‐incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X‐ray detectors that can be curved to a radius as low as 2 mm with low deviation in X‐ray response under 100 repeated bending cycles while maintaining an industry‐standard ultra‐low dark current of 0.03 ± 0.01 pA mm−2.
- 29 December 2021
- Published by Wiley in Surface and Interface Analysis
- Vol. 54 (4) , 331-340
OrbiSIMS metrology Part I: Optimisation of the target potential and collision cell pressure
In 2017, we introduced the OrbiSIMS instrument that features a dual analyser configuration with a time‐of‐flight (ToF) mass spectrometer (MS) and an Orbitrap MS, which confer advantages of speed and high‐performance mass spectrometry, respectively. The ability to combine the MS performance usually found in a state‐of‐the‐art proteomics and metabolomics MS with 3D imaging at the microscale and from nanolayers of V T , and the collision cell pressure, P , in the transfer optics on the transmitted secondary ion intensities. We measure V T – P maps of the ions across the mass range for Ag as a representative of inorganic materials and two different organic materials, Irganox 1010 and NPB (N,N′‐Di[1‐naphthyl]‐N,N′‐diphenyl‐4,4′‐biphenyldiamine). The manufacturer's defaults for these values ensure very good transmission for a broad range of analyte classes. However, the maps reveal a sometimes complex behaviour and indicate the possibility for additional separation of ions based on their shape, labile nature and kinetics of formation. Guidance is provided on how to optimise these parameters for sensitivity for different material classes and also the need for optimisation to improve spectral repeatability and reproducibility.
- 29 December 2021
- Published by Wiley in Surface and Interface Analysis
- Vol. 54 (4) , 331-340
OrbiSIMS metrology Part I: Optimisation of the target potential and collision cell pressure
In 2017, we introduced the OrbiSIMS instrument that features a dual analyser configuration with a time‐of‐flight (ToF) mass spectrometer (MS) and an Orbitrap MS, which confer advantages of speed and high‐performance mass spectrometry, respectively. The ability to combine the MS performance usually found in a state‐of‐the‐art proteomics and metabolomics MS with 3D imaging at the microscale and from nanolayers of V T , and the collision cell pressure, P , in the transfer optics on the transmitted secondary ion intensities. We measure V T – P maps of the ions across the mass range for Ag as a representative of inorganic materials and two different organic materials, Irganox 1010 and NPB (N,N′‐Di[1‐naphthyl]‐N,N′‐diphenyl‐4,4′‐biphenyldiamine). The manufacturer's defaults for these values ensure very good transmission for a broad range of analyte classes. However, the maps reveal a sometimes complex behaviour and indicate the possibility for additional separation of ions based on their shape, labile nature and kinetics of formation. Guidance is provided on how to optimise these parameters for sensitivity for different material classes and also the need for optimisation to improve spectral repeatability and reproducibility.