M'HAmed El Mansouri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M'HAmed El Mansouri has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Mohammed Talbi
Higher Institute of Nursing Professions and Health Techniques, Rabat, Morocco; Ibn Tofail University, Faculty of Sciences, Department of Physics, Laboratory of Materials and Subatomic Physics, Kenitra, Morocco; Faculty of Sciences, Mohammed V University, LPHE-M&S, Rabat, Morocco
5 shared publications - Oussama Nhila
Faculty of Sciences, Department of Physics, Laboratory of Materials and Subatomic Physics, Ibn Tofail University, Kenitra, Morocco
5 shared publications - Zakaria Tahiri
Biophysics Laboratory, Life and Health Sciences Research Laboratory, Faculty of Medicine and Pharmacy of Tangier, Abdelmalek Essaâdi University, Tetouan, Morocco
5 shared publications Mohammed Talbi
Faculty of Sciences, Physical Sciences and Engineering, Moulay Ismail University, Meknes, Morocco
3 shared publicationsAbdelmajid Choukri
Laboratory of Materials and Subatomic Physics, Faculty of Sciences, Department of Physics, Ibn Tofail University, Kenitra, Morocco
2 shared publications- Hamza Sekkat
Laboratory of Sciences and Engineering of Biomedicals, Biophysics and Health, Higher Institute of Health Sciences, Hassan 1st University, Settat, Morocco
2 shared publications
Latest Publications
- 9 January 2024
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 179 (5-6) , 634-641
Determination of water-equivalent diameter (Dw) and size-specific dose estimates (SSDE) for adult patients in abdominal CT examinations
- 9 January 2024
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 179 (5-6) , 634-641
Determination of water-equivalent diameter (Dw) and size-specific dose estimates (SSDE) for adult patients in abdominal CT examinations
- Open Access
- 1 January 2024
- Published by EDP Sciences in Radioprotection
- Vol. 59 (1) , 50-54
Establishment of local diagnostic reference levels for breast cancer CT protocols in radiotherapy in a single Moroccan center
The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 yr during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8 mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.
- 1 January 2024
- Published by EDP Sciences in Radioprotection
- Vol. 59 (1) , 50-54
Open AccessEstablishment of local diagnostic reference levels for breast cancer CT protocols in radiotherapy in a single Moroccan center
The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 yr during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8 mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.
- 31 August 2023
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 23 (5) , 2039-2043
Application of the Pareto Tool for the Analysis of CT Scanner Failures
- 31 August 2023
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 23 (5) , 2039-2043
Application of the Pareto Tool for the Analysis of CT Scanner Failures
- 24 May 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (6) , 1648-1653
Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
Size-specific dose estimates (SSDE) are the latest topic of interest in patient radiation–dose studies in computed tomography (CT). The aim of this study is to calculate and evaluate the doses (SSDE) by measuring the effective diameter (ED) of cross-sectional images collected during CT examinations of the chest and abdomen in Moroccan hospitals. Doses (SSDE) were calculated based on cross-sectional images by measuring the effective diameters of 75 patients in both examinations (45 for the thorax and 30 for the abdomen). Specific conversion factors for (ED) were used to convert the registered CTDIvol to SSDE, according to the instruction in the American Association of Physicists (AAPM) Report 204. In thoracic CT, the CTDIvol and SSDE values ranged from 5.8 to 10.7 mGy (mean: 8.08) and 9.55 to 15.37 mGy (mean: 12.13), respectively. For abdominal CT, CTDIvol and SSDE values ranged from 4.8 to 12.2 mGy (mean: 7.95) and 8.01 to 14.15 mGy (mean: 11.31), respectively. The results show that the SSDE is a useful tool and could potentially educate CT operators on its effective use as a way to optimize radiation dose instead of CTDIvol, in particular to establish diagnostic reference levels.
- 24 May 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (6) , 1648-1653
Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
Size-specific dose estimates (SSDE) are the latest topic of interest in patient radiation–dose studies in computed tomography (CT). The aim of this study is to calculate and evaluate the doses (SSDE) by measuring the effective diameter (ED) of cross-sectional images collected during CT examinations of the chest and abdomen in Moroccan hospitals. Doses (SSDE) were calculated based on cross-sectional images by measuring the effective diameters of 75 patients in both examinations (45 for the thorax and 30 for the abdomen). Specific conversion factors for (ED) were used to convert the registered CTDIvol to SSDE, according to the instruction in the American Association of Physicists (AAPM) Report 204. In thoracic CT, the CTDIvol and SSDE values ranged from 5.8 to 10.7 mGy (mean: 8.08) and 9.55 to 15.37 mGy (mean: 12.13), respectively. For abdominal CT, CTDIvol and SSDE values ranged from 4.8 to 12.2 mGy (mean: 7.95) and 8.01 to 14.15 mGy (mean: 11.31), respectively. The results show that the SSDE is a useful tool and could potentially educate CT operators on its effective use as a way to optimize radiation dose instead of CTDIvol, in particular to establish diagnostic reference levels.
- 11 March 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (2) , 149-155
Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco
In Morocco, the radiation protection of patients undergoing medical imaging examinations using ionizing radiation sources is now governed by specific provisions of Chapter VII of Law no142-12 (Loi no142-12 – AMSSNuR, 2015). The principle of justification of procedures and the principle of optimization of doses delivered constitute the basis of the legislation governing medical exposure. DRLs are considered as an important optimization tool encouraging healthcare professionals to optimize their practice and assure a better patient safety. In this survey, Local Diagnostic Reference Levels (LDRLs) were established for the eight most frequent examinations in Morocco. Data from 1747 patients were collected from seven regional hospitals. The proposed LDRLs were defined as the 75th percentile of the mean entrance surface dose distribution (ESD) in mGy using the indirect dosimetry method according to the IAEA Report Series No. 457. The LDRLs values reported in this study were for the eight examinations: skull (PA) 2.8 mGy, chest (PA) 0.51 mGy, abdomen (AP) 7.6 mGy, pelvis (AP) 6.45 mGy, lumbar (AP) 7.8 mGy, lumbar (Lat) 10.7 mGy, cervical (AP) 2.2 mGy, and cervical (Lat) 2.4 mGy. The DRLs reported in Morocco were compared with those of international authorities and other countries: IRSN (France), NRPB (UK), Japan, Sudan, and Iran. The present work assesses the local DRLs in Morocco and constitutes a starting point that will provide professionals with a tool to help them optimize the doses delivered to patients. Furthermore, the definition of national DRLs by radiography is an essential step in the process of optimizing medical exposures.
- 11 March 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (2) , 149-155
Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco
In Morocco, the radiation protection of patients undergoing medical imaging examinations using ionizing radiation sources is now governed by specific provisions of Chapter VII of Law no142-12 (Loi no142-12 – AMSSNuR, 2015). The principle of justification of procedures and the principle of optimization of doses delivered constitute the basis of the legislation governing medical exposure. DRLs are considered as an important optimization tool encouraging healthcare professionals to optimize their practice and assure a better patient safety. In this survey, Local Diagnostic Reference Levels (LDRLs) were established for the eight most frequent examinations in Morocco. Data from 1747 patients were collected from seven regional hospitals. The proposed LDRLs were defined as the 75th percentile of the mean entrance surface dose distribution (ESD) in mGy using the indirect dosimetry method according to the IAEA Report Series No. 457. The LDRLs values reported in this study were for the eight examinations: skull (PA) 2.8 mGy, chest (PA) 0.51 mGy, abdomen (AP) 7.6 mGy, pelvis (AP) 6.45 mGy, lumbar (AP) 7.8 mGy, lumbar (Lat) 10.7 mGy, cervical (AP) 2.2 mGy, and cervical (Lat) 2.4 mGy. The DRLs reported in Morocco were compared with those of international authorities and other countries: IRSN (France), NRPB (UK), Japan, Sudan, and Iran. The present work assesses the local DRLs in Morocco and constitutes a starting point that will provide professionals with a tool to help them optimize the doses delivered to patients. Furthermore, the definition of national DRLs by radiography is an essential step in the process of optimizing medical exposures.
- 1 March 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (2) , 123-126
Evaluation of Moroccan physician’s knowledge about radiation doses and risks from pediatric computed tomography
The large use of Computed Tomography Scan (CT scan) is a principal cause of increasing medical ionizing radiation exposure. Children are considered a population at risk for the occurrence of radiation-induced pathologies, and the implementation of radiation protection measures relies on the knowledge and skills of healthcare professionals. This analytical cross-sectional study aimed to assess the knowledge of Moroccan physicians prescribing pediatric CT scan examinations on the radiation protection of patients, radiation doses, and potential health risks of radiation exposure from CT scan. A questionnaire was distributed to all clinicians on the medical staff who prescribe pediatric CT examinations in five Moroccan pediatric hospitals. The questions have a focusing on prescribers’ practices and their knowledge of patient radiation protection, radiation doses, the potential health risks of radiation exposure from CT scan, and training on radiation protection. One hundred and ninety-two questionnaires were submitted to prescribers and among them, 88% responded. The data were analyzed using the Statistical Package of Microsoft Office Excel. Knowledge gaps regarding CT scan radiation doses and associated health risks among Moroccan physicians are evident from this study results, initial and continuing training of health care staff and the implementation of referral guidelines for medical imaging could lead to improve practitioners’ knowledge of patient radiation protection.
- 1 March 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (2) , 123-126
Evaluation of Moroccan physician’s knowledge about radiation doses and risks from pediatric computed tomography
The large use of Computed Tomography Scan (CT scan) is a principal cause of increasing medical ionizing radiation exposure. Children are considered a population at risk for the occurrence of radiation-induced pathologies, and the implementation of radiation protection measures relies on the knowledge and skills of healthcare professionals. This analytical cross-sectional study aimed to assess the knowledge of Moroccan physicians prescribing pediatric CT scan examinations on the radiation protection of patients, radiation doses, and potential health risks of radiation exposure from CT scan. A questionnaire was distributed to all clinicians on the medical staff who prescribe pediatric CT examinations in five Moroccan pediatric hospitals. The questions have a focusing on prescribers’ practices and their knowledge of patient radiation protection, radiation doses, the potential health risks of radiation exposure from CT scan, and training on radiation protection. One hundred and ninety-two questionnaires were submitted to prescribers and among them, 88% responded. The data were analyzed using the Statistical Package of Microsoft Office Excel. Knowledge gaps regarding CT scan radiation doses and associated health risks among Moroccan physicians are evident from this study results, initial and continuing training of health care staff and the implementation of referral guidelines for medical imaging could lead to improve practitioners’ knowledge of patient radiation protection.
- Open Access
- 31 January 2022
- Published by Moroccan Association for Research and Ethics in (IJRE) International Journal of Research and Ethics (ISSN 2665-7481)
- Vol. 5 (1)
Validation of X-Ray Spectra in screening mammography simulated with Monte Carlo
Background: Screening mammography is the examination of reference in the fight against breast cancer because of its sensitivity in detecting microlesions. Thus, it is crucial to ensure a good quality examination with the most suitable dose, requirements will depend on the choice of exposure parameters (anode/filter, tube voltage and current) and the acquisition procedures. To optimize practices, we must understand the relationship between breast dose and image quality. This can be reached by knowing the X-ray energy spectra. This study aims to generate spectra of a mammographic x-ray tube, using two types of targets, Mo and Rh by MONTE CARLO simulation using Gate code (GEANT4). Methods: To predict the X-ray spectra for the Mo/Mo and Rh/Rh target/filter of the screening mammography tube; Monte Carlo modelization has been carried out using the GATE code (GEANT4), the generated spectra are validated by comparing them with those of the IPEM report 78. Results: The curves of the spectra obtained by the Monte Carlo simulation have been normalized for a reliable comparison. The evaluation of these curves has been performed using a statistical analysis with the student’s t-test. The results show that the energy spectra of the GATE code are in agreement with those produced by the IPEM 78 report, no statistically significant differences have been observed between the IPEM and simulated spectra (p<.05), even though there are slight differences between them, especially in the characteristic intensity of the K-beam and in the low-energy range. Conclusion: Monte Carlo simulation is a reliable method for generating mammography spectra and can be used as a tool for optimizing acquisition parameters. Keywords: Mammography, Screening, X-ray spectra, Gate, Monte Carlo Simulation, GEANT4, IPEM Report 78, Analysis, Molybdenum, Rhodium
- 31 January 2022
- Published by Moroccan Association for Research and Ethics in (IJRE) International Journal of Research and Ethics (ISSN 2665-7481)
- Vol. 5 (1)
Open AccessValidation of X-Ray Spectra in screening mammography simulated with Monte Carlo
Background: Screening mammography is the examination of reference in the fight against breast cancer because of its sensitivity in detecting microlesions. Thus, it is crucial to ensure a good quality examination with the most suitable dose, requirements will depend on the choice of exposure parameters (anode/filter, tube voltage and current) and the acquisition procedures. To optimize practices, we must understand the relationship between breast dose and image quality. This can be reached by knowing the X-ray energy spectra. This study aims to generate spectra of a mammographic x-ray tube, using two types of targets, Mo and Rh by MONTE CARLO simulation using Gate code (GEANT4). Methods: To predict the X-ray spectra for the Mo/Mo and Rh/Rh target/filter of the screening mammography tube; Monte Carlo modelization has been carried out using the GATE code (GEANT4), the generated spectra are validated by comparing them with those of the IPEM report 78. Results: The curves of the spectra obtained by the Monte Carlo simulation have been normalized for a reliable comparison. The evaluation of these curves has been performed using a statistical analysis with the student’s t-test. The results show that the energy spectra of the GATE code are in agreement with those produced by the IPEM 78 report, no statistically significant differences have been observed between the IPEM and simulated spectra (p<.05), even though there are slight differences between them, especially in the characteristic intensity of the K-beam and in the low-energy range. Conclusion: Monte Carlo simulation is a reliable method for generating mammography spectra and can be used as a tool for optimizing acquisition parameters. Keywords: Mammography, Screening, X-ray spectra, Gate, Monte Carlo Simulation, GEANT4, IPEM Report 78, Analysis, Molybdenum, Rhodium
- 12 January 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (1) , 61-66
Establishing local diagnostic reference levels for adult computed tomography in Morocco
In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed. The aim of this study was to evaluate the radiation doses received by patients for the most common adult CT examinations in order to establish local diagnostic reference levels (DRLs). Data from 1016 adult patients were collected during 3 months from four Moroccan hospitals. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for the most common examinations including head, chest and abdomen. The DRL for each examination was compared with other studies. The established DRLs in Morocco in terms of CTDIvol were 57.4, 12.3 and 10.9 for CT examinations of the head, chest, abdomen, respectively. For DLP, they were 1020, 632 and 714, respectively. These established DRLs for CTDIvol were almost similar to the UK DRLs at all examinations, higher than the Egyptian DRLs and lower than the Japanese DRLs at the head CT examination, lower than the DRLs from Egypt and Japan at the CT abdomen examination. In terms of DLP, the DRLs were higher than those of the British studies, lower than those of the Egyptian and Japanese studies at the head CT examination were higher at chest CT and lower at abdominal CT than those of all selected studies. The higher level of established DRLs in our study demonstrates the requirement of an optimization process while keeping a good image quality for a reliable diagnosis.
- 12 January 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (1) , 61-66
Establishing local diagnostic reference levels for adult computed tomography in Morocco
In Morocco, the radiation doses received by adult patients are increasing due to the number of CT examinations performed and the larger number of computed tomography (CT) scanners installed. The aim of this study was to evaluate the radiation doses received by patients for the most common adult CT examinations in order to establish local diagnostic reference levels (DRLs). Data from 1016 adult patients were collected during 3 months from four Moroccan hospitals. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for the most common examinations including head, chest and abdomen. The DRL for each examination was compared with other studies. The established DRLs in Morocco in terms of CTDIvol were 57.4, 12.3 and 10.9 for CT examinations of the head, chest, abdomen, respectively. For DLP, they were 1020, 632 and 714, respectively. These established DRLs for CTDIvol were almost similar to the UK DRLs at all examinations, higher than the Egyptian DRLs and lower than the Japanese DRLs at the head CT examination, lower than the DRLs from Egypt and Japan at the CT abdomen examination. In terms of DLP, the DRLs were higher than those of the British studies, lower than those of the Egyptian and Japanese studies at the head CT examination were higher at chest CT and lower at abdominal CT than those of all selected studies. The higher level of established DRLs in our study demonstrates the requirement of an optimization process while keeping a good image quality for a reliable diagnosis.
- 1 December 2021
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 76 (S1) , S88-S94
Computed Tomography Scan Optimization of Chest and Abdomen Protocols
This work aims to optimize the scanning parameters of Chest and Abdomen protocols in computed tomography, whilst maintaining imagequality and reducing the
- 1 December 2021
- Published by Allerton Press in Moscow University Physics Bulletin
- Vol. 76 (S1) , S88-S94
Computed Tomography Scan Optimization of Chest and Abdomen Protocols
This work aims to optimize the scanning parameters of Chest and Abdomen protocols in computed tomography, whilst maintaining imagequality and reducing the