ONOussama Nhila

Oussama Nhila

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oussama Nhila has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • M'HAmed El Mansouri

    Ibn Tofail University, Faculty of Sciences, Department of Physics, Laboratory of Materials and Subatomic Physics, P.O. Box 133, Kenitra, Morocco

    5 shared publications
  • Mohammed Talbi

    5 shared publications
  • El Mahjoub Chakir

    4 shared publications
  • Mohammed Talbi

    Higher Institute of Nursing Professions and Health Techniques, Rabat, Morocco; Ibn Tofail University, Faculty of Sciences, Department of Physics, Laboratory of Materials and Subatomic Physics, Kenitra, Morocco; Faculty of Sciences, Mohammed V University, LPHE-M&S, Rabat, Morocco

    4 shared publications
  • Zakaria Tahiri

    Biophysics Laboratory, Life and Health Sciences Research Laboratory, Faculty of Medicine and Pharmacy of Tangier, Abdelmalek Essaâdi University, Tetouan, Morocco

    4 shared publications
  • Hamza Sekkat

    Laboratory of Sciences and Engineering of Biomedicals, Biophysics and Health, Higher Institute of Health Sciences, Hassan 1st University, Settat, Morocco

    3 shared publications

Latest Publications

  • Open Access

    Optimization of a CT simulation protocol for breast cancer radiotherapy using response surface methodology

    by Oussama Nhila, Mohammed Talbi, Morad Erraoudi, Maroine Tahiri, M'HAmed El Mansouri, El Mahjoub Chakir

  • Open Access

    From dose to decision: IAEA TECDOC-870–based risk modeling of CBCT and practical protocol recommendations

    by H. Sekkat, A. Khallouqi, A. Wahji, M. Boulaazaim, O. Nhila, A. Halimi, O. El Rhazouani, O. Elmouden, A. Bannan, Y. Berrada


  • Dosimetric impact of CT-RED calibration curve variations from different kVp settings on breast cancer treatment planning

    by Oussama Nhila, Mohammed Talbi, M’hAmed El Mansouri, Morad Erraoudi, El Mahjoub Chakir

    The choice of a CT-RED calibration curve directly influences the accuracy of dose calculation in treatment planning systems (TPS), depending on treatment technique, anatomical site and calculation algorithm. This study aimed to evaluate the impact of variations in CT-RED calibration curves due to different tube voltages (kVp) on breast cancer treatment plans as a function of calculation algorithm. CT-RED calibration curves were generated using a CIRS M062 phantom scanned with a 16-slice HITACHI Supria CT scanner at 80, 100, 120, and 140 kVp. These curves were applied to treatment plans for left breast cancer using the Collapsed Cone (CC) and X-ray Voxel-based Monte Carlo (XVMC++) algorithms in MONACO TPS (v6.6.2). Dose-volume histograms and dose statistics were analyzed to assess dose metrics for planned target volumes (PTV) and organs at risk (OAR). Monte Carlo-based dose calculations showed significant sensitivity to kVp settings, while CC results exhibited clinically negligible effects, underscoring that the impact of kVp on dose calculation depends on the algorithm used. Thus, to ensure accurate dose calculations, it is important to adjust calibration curves for each kVp setting when using Monte Carlo algorithms. Furthermore, it is recommended to include this adjustment into the CC algorithm, despite the minimal differences observed, in order to ensure consistency with the ALARA (As Low As Reasonably Achievable) principle.


  • Determination of water-equivalent diameter (Dw) and size-specific dose estimates (SSDE) for adult patients in abdominal CT examinations

    by M'HAmed El Mansouri, Zakaria Tahiri, Mohammed Talbi, Oussama Nhila, Hamza Sekkat, Abdelmajid Choukri


  • Open Access

    Establishment of local diagnostic reference levels for breast cancer CT protocols in radiotherapy in a single Moroccan center

    by O. Nhila, M. Talbi, M.A. Youssoufi, M. El Mansouri, Z. Tahiri, E.M. Chakir, M. Azougagh

    The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 yr during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8 mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.


  • Application of the Pareto Tool for the Analysis of CT Scanner Failures

    by M’hAmed El Mansouri, Mohammed Talbi, Zakaria Tahiri, Oussama Nhila, Morad El Kafhali, Hamza Sekkat


  • The effect of CT reconstruction filter selection on Hounsfield units in radiotherapy treatment planning

    by Oussama Nhila, Mohammed Talbi, M’hAmed El Mansouri, Moulay Ali Youssoufi, Morad Erraoudi, El Mahjoub Chakir, Mohamed Azougagh

    Introduction: This work aims to evaluate the effect of Hitachi 16-slice scanner reconstruction filters on Hounsfield unit (HU) variations. In the literature, there is a lack of information from a wide variety of scanners in this regard. In addition, not all studies have investigated the effect of reconstruction filters on HU in an exhaustive way. Methods: The computerised imaging reference system electron density phantom (model 062M) was scanned with different substitute materials of different density from Hitachi 16-slice computed tomography. The raw images were obtained with four tube voltage settings: 80 kVp, 100 kVp, 120 kVp and 140 kVp. The raw images for each energy level were then reconstructed using different reconstruction filters. Results: The HU values of dense bone were significantly different when changing the reconstruction filters without beam hardening correction (BHC). Nevertheless, when selecting the BHC, this variation decreases heavily for 80 kVp and decreases slightly for 140 kVp, but it remains outside the tolerance of ±50 HU. However, for 100 kVp and 120 kVp, the differences in HU values become within the tolerances indicated for dense bone. Conclusions: Changing image reconstruction filters during a dosimetric scan had a significant effect on HU in dense bone. Therefore, it is recommended to evaluate this effect during the commissioning phase. As a result, this study provides a methodology to comprehensively investigate the effect of reconstruction filters on HU.


  • Evaluation of CT Acquisition Protocols Effect on Hounsfield Units and Optimization of CT-RED Calibration Curve Selection in Radiotherapy Treatment Planning Systems

    by Oussama Nhila, Mohammed Talbi, M’HAmed El Mansouri, Mahmoud El Katib, El Mahjoub Chakir

    The acquisition parameters affect the Hounsfield units (HU) on a CT scanner used for radiotherapy treatment planning. The degree of effect depends on the c


  • Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco

    by M. Talbi, Z. Tahiri, K. Eddaoui, M. El Mansouri, O. Nhila, M. Benmessaoud, I. Ait Ouaggou, E. Chakir, R. Sebihi, M. Khalis

    In Morocco, the radiation protection of patients undergoing medical imaging examinations using ionizing radiation sources is now governed by specific provisions of Chapter VII of Law no142-12 (Loi no142-12 – AMSSNuR, 2015). The principle of justification of procedures and the principle of optimization of doses delivered constitute the basis of the legislation governing medical exposure. DRLs are considered as an important optimization tool encouraging healthcare professionals to optimize their practice and assure a better patient safety. In this survey, Local Diagnostic Reference Levels (LDRLs) were established for the eight most frequent examinations in Morocco. Data from 1747 patients were collected from seven regional hospitals. The proposed LDRLs were defined as the 75th percentile of the mean entrance surface dose distribution (ESD) in mGy using the indirect dosimetry method according to the IAEA Report Series No. 457. The LDRLs values reported in this study were for the eight examinations: skull (PA) 2.8 mGy, chest (PA) 0.51 mGy, abdomen (AP) 7.6 mGy, pelvis (AP) 6.45 mGy, lumbar (AP) 7.8 mGy, lumbar (Lat) 10.7 mGy, cervical (AP) 2.2 mGy, and cervical (Lat) 2.4 mGy. The DRLs reported in Morocco were compared with those of international authorities and other countries: IRSN (France), NRPB (UK), Japan, Sudan, and Iran. The present work assesses the local DRLs in Morocco and constitutes a starting point that will provide professionals with a tool to help them optimize the doses delivered to patients. Furthermore, the definition of national DRLs by radiography is an essential step in the process of optimizing medical exposures.


  • Open Access

    Validation of X-Ray Spectra in screening mammography simulated with Monte Carlo

    by Mohammed Talbi, M'HAmed El Mansouri, Aziz Oustous, Oussama Nhila, Rajaa Sebihi, Mohammed Khalis

    Background: Screening mammography is the examination of reference in the fight against breast cancer because of its sensitivity in detecting microlesions. Thus, it is crucial to ensure a good quality examination with the most suitable dose, requirements will depend on the choice of exposure parameters (anode/filter, tube voltage and current) and the acquisition procedures. To optimize practices, we must understand the relationship between breast dose and image quality. This can be reached by knowing the X-ray energy spectra. This study aims to generate spectra of a mammographic x-ray tube, using two types of targets, Mo and Rh by MONTE CARLO simulation using Gate code (GEANT4). Methods: To predict the X-ray spectra for the Mo/Mo and Rh/Rh target/filter of the screening mammography tube; Monte Carlo modelization has been carried out using the GATE code (GEANT4), the generated spectra are validated by comparing them with those of the IPEM report 78. Results: The curves of the spectra obtained by the Monte Carlo simulation have been normalized for a reliable comparison. The evaluation of these curves has been performed using a statistical analysis with the student’s t-test. The results show that the energy spectra of the GATE code are in agreement with those produced by the IPEM 78 report, no statistically significant differences have been observed between the IPEM and simulated spectra (p<.05), even though there are slight differences between them, especially in the characteristic intensity of the K-beam and in the low-energy range. Conclusion: Monte Carlo simulation is a reliable method for generating mammography spectra and can be used as a tool for optimizing acquisition parameters. Keywords: Mammography, Screening, X-ray spectra, Gate, Monte Carlo Simulation, GEANT4, IPEM Report 78, Analysis, Molybdenum, Rhodium