Seok Young Koh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seok Young Koh has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jung-Eun Cheon
Department of Radiology, Seoul National University Children’s Hospital, Seoul National University College of Medicine, Seoul, Korea
2 shared publications - Woo Sun Kim
Seoul National University Hospital
2 shared publications - Yeon Jin Cho
Department of Radiology, Seoul National University College of Medicine, Seoul National University Children’s Hospital, 101 Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea
2 shared publications - Young Hun Choi
Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
2 shared publications - Hyo-Jin Kang
Department of Radiology, Seoul National University Hospital, Seoul, Korea
1 shared publication - Ijin Joo
Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak‑ro, Jongno‑gu, Seoul 03080, Korea
1 shared publication
Latest Publications
- 6 February 2023
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 29 (5) , 497-507
High-resolution MR imaging with gadoxetate disodium for the comprehensive evaluation of potential living liver donors
Several major transplantation centers have used composite multimodality evaluation for the preoperative evaluation of potential living liver donors. This approach can be time-consuming and, although rare, can cause complications. We aimed to demonstrate the clinical feasibility of our comprehensive preoperative MR protocol for the preoperative assessment of living liver donor candidates instead of composite multimodality evaluation. Thirty-five consecutive living liver donor candidates underwent multiphasic liver CT and comprehensive donor protocol MR examinations for preoperative evaluation in a single large-volume liver transplantation (LT) center. Three blinded abdominal radiologists reviewed the CT and MR images for vascular and biliary variations. The strength of agreement between CT and MR angiography was assessed using the kappa index. The detection rate of biliary anatomical variations was calculated. The sensitivity and specificity for detecting significant steatosis (>5%) were calculated. The estimated total volume and right lobe volumes measured by MR volumetry were compared with the corresponding CT volumetry measurements using the intraclass correlation coefficient (ICC). Among the 35 patients, 26 underwent LT. The measurement of agreement showed a moderate to substantial agreement between CT and MR angiography interpretations (kappa values, 0.47–0.79; p < 0.001). Combining T2-weighted and T1-weighted MR cholangiography techniques detected all biliary anatomical variations in 9 of the 26 patients. MR-proton density fat fraction showed a sensitivity of 100% (3/3) and a specificity of 91.3% (21/23) for detecting pathologically determined steatosis (>5%). MR volumetry reached an excellent agreement with CT volumetry (reviewers 1 and 2: ICC, 0.92; 95% CI, 0.84–0.96). Our one-stop comprehensive liver donor MR imaging protocol can provide complete information regarding hepatic vascular and biliary anatomies, hepatic parenchymal quality, and liver volume for living liver donor candidates and can replace composite multimodality evaluation.
- 6 February 2023
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 29 (5) , 497-507
High-resolution MR imaging with gadoxetate disodium for the comprehensive evaluation of potential living liver donors
Several major transplantation centers have used composite multimodality evaluation for the preoperative evaluation of potential living liver donors. This approach can be time-consuming and, although rare, can cause complications. We aimed to demonstrate the clinical feasibility of our comprehensive preoperative MR protocol for the preoperative assessment of living liver donor candidates instead of composite multimodality evaluation. Thirty-five consecutive living liver donor candidates underwent multiphasic liver CT and comprehensive donor protocol MR examinations for preoperative evaluation in a single large-volume liver transplantation (LT) center. Three blinded abdominal radiologists reviewed the CT and MR images for vascular and biliary variations. The strength of agreement between CT and MR angiography was assessed using the kappa index. The detection rate of biliary anatomical variations was calculated. The sensitivity and specificity for detecting significant steatosis (>5%) were calculated. The estimated total volume and right lobe volumes measured by MR volumetry were compared with the corresponding CT volumetry measurements using the intraclass correlation coefficient (ICC). Among the 35 patients, 26 underwent LT. The measurement of agreement showed a moderate to substantial agreement between CT and MR angiography interpretations (kappa values, 0.47–0.79; p < 0.001). Combining T2-weighted and T1-weighted MR cholangiography techniques detected all biliary anatomical variations in 9 of the 26 patients. MR-proton density fat fraction showed a sensitivity of 100% (3/3) and a specificity of 91.3% (21/23) for detecting pathologically determined steatosis (>5%). MR volumetry reached an excellent agreement with CT volumetry (reviewers 1 and 2: ICC, 0.92; 95% CI, 0.84–0.96). Our one-stop comprehensive liver donor MR imaging protocol can provide complete information regarding hepatic vascular and biliary anatomies, hepatic parenchymal quality, and liver volume for living liver donor candidates and can replace composite multimodality evaluation.
- Open Access
- 1 April 2022
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 41 (2) , 325-334
Shear-wave elastography for the assessment of testicular involvement of hematologic malignancies in children and young adults: a feasibility study
Purpose: This study aimed to assess the feasibility of shear-wave elastography (SWE) for assessing the testicular involvement of hematologic malignancies in children and young adults.Methods: Eight patients (mean age, 11.0 years; range, 0.8 to 20 years) with biopsy-confirmed testicular involvement of hematologic malignancy between January 2018 and December 2020 were retrospectively evaluated. Multiparametric ultrasound examinations, including grayscale, color Doppler ultrasonography (CDUS), and SWE, were performed. Stiffness was measured in the involved testicular area and contralateral normal parenchyma. If there was bilateral testicular involvement, the stiffness of the involved area and the adjacent normal echoic parenchyma was measured on one testis. The Mann-Whitney U test was used to compare stiffness values.Results: On grayscale, the testicular lesions were noted as a solitary mass in one patient, multiple lesions in four patients, and diffuse involvement in three patients. On CDUS and SWE, all patients demonstrated increased vascularity, and the stiffness of the involved area was higher than the values of normal parenchyma (the involved area vs. normal parenchyma, 11.6 kPa [3.9-20.2 kPa] vs. 2.9 kPa [1.1-3.7 kPa], P=0.003). The ratio of stiffness between the involved area and normal parenchyma was 3.4, ranging from 1.9 to 5.1. One patient showed decreased stiffness on follow-up SWE after treatment (affected testis vs. normal testis: initial, 13.8 vs. 3.2 kPa; 1 year later, 2.2 vs. 2.4 kPa).Conclusion: Increased testicular stiffness on SWE in children and young adults with hematologic malignancies suggests the possibility of testicular involvement.
- 1 April 2022
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 41 (2) , 325-334
Open AccessShear-wave elastography for the assessment of testicular involvement of hematologic malignancies in children and young adults: a feasibility study
Purpose: This study aimed to assess the feasibility of shear-wave elastography (SWE) for assessing the testicular involvement of hematologic malignancies in children and young adults.Methods: Eight patients (mean age, 11.0 years; range, 0.8 to 20 years) with biopsy-confirmed testicular involvement of hematologic malignancy between January 2018 and December 2020 were retrospectively evaluated. Multiparametric ultrasound examinations, including grayscale, color Doppler ultrasonography (CDUS), and SWE, were performed. Stiffness was measured in the involved testicular area and contralateral normal parenchyma. If there was bilateral testicular involvement, the stiffness of the involved area and the adjacent normal echoic parenchyma was measured on one testis. The Mann-Whitney U test was used to compare stiffness values.Results: On grayscale, the testicular lesions were noted as a solitary mass in one patient, multiple lesions in four patients, and diffuse involvement in three patients. On CDUS and SWE, all patients demonstrated increased vascularity, and the stiffness of the involved area was higher than the values of normal parenchyma (the involved area vs. normal parenchyma, 11.6 kPa [3.9-20.2 kPa] vs. 2.9 kPa [1.1-3.7 kPa], P=0.003). The ratio of stiffness between the involved area and normal parenchyma was 3.4, ranging from 1.9 to 5.1. One patient showed decreased stiffness on follow-up SWE after treatment (affected testis vs. normal testis: initial, 13.8 vs. 3.2 kPa; 1 year later, 2.2 vs. 2.4 kPa).Conclusion: Increased testicular stiffness on SWE in children and young adults with hematologic malignancies suggests the possibility of testicular involvement.
- Open Access
- 1 January 2022
- Published by XMLink in Korean Journal of Radiology
- Vol. 23 (3) , 343-354
Deep Learning-Assisted Diagnosis of Pediatric Skull Fractures on Plain Radiographs
Choi JW, et al. Korean J Radiol. 2022 Jan;23:e9. https://doi.org/10.3348/kjr.2021.0449
- 1 January 2022
- Published by XMLink in Korean Journal of Radiology
- Vol. 23 (3) , 343-354
Open AccessDeep Learning-Assisted Diagnosis of Pediatric Skull Fractures on Plain Radiographs
Choi JW, et al. Korean J Radiol. 2022 Jan;23:e9. https://doi.org/10.3348/kjr.2021.0449