Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mario Muñoz has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating deep learning approaches for AI-assisted lung ultrasound diagnosis: an international multi-center and multi-scanner study

    by Mario Muñoz, Xi Han, Jorge Camacho, Tiziano Perrone, Andrea Smargiassi, Riccardo Inchingolo, Yale Tung-Chen, Libertario Demi

    Lung ultrasound (LUS) interpretation is often subjective and operator-dependent, motivating the development of automated, artificial intelligence (AI)-based methods. This international, multi-center study evaluated two distinct deep learning approaches for automated LUS severity scoring for pulmonary infections caused by COVID-19: a pre-trained classification model (CM) and a segmentation model based method (SM); assessing performance at video, exam, and prognostic levels. Two datasets were analyzed: one comprising data from multiple scanners and another using data from a single scanner. Results showed that the SM achieved prognostic-level agreement with expert clinicians comparable to that of the CM. Furthermore, at the exam level, over 84% of examinations were classified with acceptable error (≤ 10 score difference) across both models and datasets, reaching both methods an agreement higher than 95% on the dataset acquired by a single scanner. The obtained results demonstrate the potential of AI-assisted LUS for reliable prognostic assessment and highlight that image quality and acquisition technique are key factors in achieving consistent and generalizable model performance, as well as the potential for international clinical translations.


  • Open Access

    Three-Dimensional Convolutional Neural Network for Ultrasound Surface Echo Detection

    by Mario Muñoz, Adrián Rubio, Marcelo Larrea, Jorge F. Cruza, Jorge Camacho, Guillermo Cosarinsky

    Ultrasound array imaging frequently employs a coupling medium to facilitate wave transmission from the transducer to the target component. Surface echoes, identified by their high-amplitude peaks, are crucial for determining the Time of Flight (TOF) in each channel, which is essential for deriving imaging focal laws. Accurate TOF measurement is vital in numerous applications, such as Non-Destructive Testing (NDT) and medical imaging. Conventional methods, such as threshold crossing and peak search, are highly sensitive to noise and spurious signals, therefore, more robust estimation techniques are needed. This study explores the application of a deep 3D Convolutional Neural Network (CNN) to detect surface echoes in Full Matrix Capture (FMC) ultrasound data. The CNN was trained on signals obtained with a matrix array and a set of reference components, utilizing a robotic arm setup to ensure precise probe positioning. Theoretical TOFs were computed based on the setup geometry to generate labeled training data. Test results indicated that the CNN model, which we have called DeepEcho3D, closely aligned with the ground truth and significantly reduced TOF estimation outliers (up to 98%) compared to traditional methods, demonstrating its potential for improved accuracy in surface echo detection.

  • Open Access

    Free-form surface reconstruction for adaptive imaging with 2D ultrasound arrays

    by Guillermo Cosarinsky, Jorge F. Cruza, Mario Muñoz, Adrián Rubio, Jorge Camacho


  • Open Access

    Deep Learning-Based Algorithms for Real-Time Lung Ultrasound Assisted Diagnosis

    by Mario Muñoz, Adrián Rubio, Guillermo Cosarinsky, Jorge F. Cruza, Jorge Camacho

    Lung ultrasound is an increasingly utilized non-invasive imaging modality for assessing lung condition but interpreting it can be challenging and depends on the operator’s experience. To address these challenges, this work proposes an approach that combines artificial intelligence (AI) with feature-based signal processing algorithms. We introduce a specialized deep learning model designed and trained to facilitate the analysis and interpretation of lung ultrasound images by automating the detection and location of pulmonary features, including the pleura, A-lines, B-lines, and consolidations. Employing Convolutional Neural Networks (CNNs) trained on a semi-automatically annotated dataset, the model delineates these pulmonary patterns with the objective of enhancing diagnostic precision. Real-time post-processing algorithms further refine prediction accuracy by reducing false-positives and false-negatives, augmenting interpretational clarity and obtaining a final processing rate of up to 20 frames per second with accuracy levels of 89% for consolidation, 92% for B-lines, 66% for A-lines, and 92% for detecting normal lungs compared with an expert opinion.


  • Open Access

    Deep Learning-Based Algorithms for Real-Time Lung Ultrasound Assisted Diagnosis

    by Mario Muñoz, Adrián Rubio, Guillermo Cosarinsky, Jorge F.Cruza, Jorge Camacho

    Lung ultrasound is an increasingly utilized non-invasive imaging modality for assessing the lung condition, but interpreting it can be challenging and depends on the operator experience. To address these challenges, this work proposes an approach that combines artificial intelligence (AI) with feature-based signal processing algorithms. We introduce a specialized deep learning model designed and trained to facilitate the analysis and interpretation of lung ultrasound images, by automating the detection and location of pulmonary features, including the pleura, A-lines, B-lines and consolidations. Employing Convolutional Neural Networks (CNNs) trained on a semi-automatically annotated dataset, the model delineates these pulmonary patterns, with the objective of enhancing diagnostic precision. Real-time post-processing algorithms further refine prediction accuracy by reducing false-positives and false-negatives, augmenting interpretational clarity and obtaining a final processing rate of up to 20 frames per second withl accuracies of 89% for consolidation, 92% for B-lines and 66% in case of A-lines compared with an expert opinion.


  • Open Access

    Deep learning for ultrasound surface echo detection

    by Guillermo Cosarinsky, Spanish National Research Council (CSIC), Mario Muñoz, Jorge F. Cruza, Adrián Rubio, Jorge Camacho

    Ultrasound array imaging techniques are often applied using a coupling medium to transmit waves from the transducer to the scanned component. In this type of tests, the echoes generated by the wave reflection at the component surface contain information that can be used to estimate the surface shape and its position relative to the probe, which are needed to compute the imaging focal laws. The most interesting feature to extract from surfaces echoes is the Time of Flight (TOF) for each reception channel. TOF measurement in acoustic signals is a problem that frequently arises not only in Non Destructive Testing (NDT), but also in medical imaging, geophysics and other fields. The surface echo in a signal is usually identified as the first high amplitude peak, and is traditionally detected with standard methods as threshold crossing, peak search or matched filters. All these methods are easily affected by Signal to Noise Ratio, which might be high in some channels, for example if the ray arrives at the corresponding element at a low sensibility angle. Moreover, spurious echoes from bubbles, the emission signal tail or echoes from other parts of the component can be incorrectly labelled as surface echoes. This kind of outliers are difficult to filter by conventional means and, thus, there is a need for more robust surface estimation methods. In this work, we study the application of a deep 3D Convolutional Neural Network (CNN) to detect surface echoes in Full Matrix Capture (FMC) ultrasound data. The CNN is trained using signals acquired with a matrix array and a reference component, using a robotic arm set-up to measure the probe position and orientation relative to the component. Thus, with knowledge of the set-up geometry, a model is used to compute the theoretical surface echo TOFs, which are used to label the data for training. The model was tested with a validation set, presenting good agreement with the ground truth. The results were compared with the threshold crossing method observing a significant reduction of outliers in the TOF estimation.

  • Open Access

    Automatic estimation of surface and probe location for 3D imaging with bidimensional arrays

    by Guillermo Cosarinsky, Jorge F. Cruza, Mario Muñoz, Jorge Camacho


  • Open Access

    Inter-Rater Variability in the Evaluation of Lung Ultrasound in Videos Acquired from COVID-19 Patients

    by Joaquin L. Herraiz, Clara Freijo, Jorge Camacho, Mario Muñoz, Ricardo González, Rafael Alonso-Roca, Jorge Álvarez-Troncoso, Luis Matías Beltrán-Romero, Máximo Bernabeu-Wittel, Rafael Blancas, et al.

    Lung ultrasound (LUS) allows for the detection of a series of manifestations of COVID-19, such as B-lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the performance of the test in a longitudinal or transverse orientation. Thirty-three physicians with advanced experience in LUS independently evaluated ultrasound videos previously acquired using the ULTRACOV system on 20 patients with confirmed COVID-19. For each patient, 24 videos of 3 s were acquired (using 12 positions with the probe in longitudinal and transverse orientations). The physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (κ = 0.74), with only a fair IRR for the presence of individual B-lines (κ = 0.36) and for confluent B-lines occupying < 50% (κ = 0.26) and a moderate IRR in consolidations and B-lines > 50% (κ = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR for LUS of COVID-19 patients may benefit from more standardized clinical protocols.


  • Open Access

    Inter-rater Variability in the Evaluation of Lung Ultrasound on Videos Acquired from COVID-19 Patients

    by Joaquin L. Herraiz, Clara Freijo, Jorge Camacho, Mario Muñoz, Ricardo González, Rafael Alonso-Roca, Jorge Álvarez-Troncoso, Luis Matías Beltrán-Romero, Máximo Bernabeu-Wittel, Rafael Blancas, et al.

    Lung ultrasound (LUS) allows the detection of a series of manifestations of COVID-19 such as B lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the impact of performing the test in the longitudinal or transverse orientation. 33 physicians with advanced experience in LUS, independently evaluated ultrasound videos previously acquired with the ULTRACOV system of 20 patients with confirmed COVID-19. In each patient, 24 videos of 3 seconds were acquired (using 12 positions with the probe in longitudinal and transverse orientations). Physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (κ = 0.74), only a fair IRR for the presence of individual B lines (κ = 0.36) and for confluent B lines occupying 50% (κ = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR in LUS of COVID-19 patients may benefit from more standardization of the clinical protocols.

  • Open Access

    Artificial Intelligence and Democratization of the Use of Lung Ultrasound in COVID-19: On the Feasibility of Automatic Calculation of Lung Ultrasound Score

    by Jorge Camacho, Mario Muñoz, Vicente Genovés, Joaquín L. Herraiz, Ignacio Ortega, Adrián Belarra, Ricardo González, David Sánchez, Roberto Carlos Giacchetta, Ángela Trueba-Vicente, et al.

    During the COVID-19 pandemic, lung ultrasound has been revealed as a powerful technique for diagnosis and follow-up of pneumonia, the principal complication of SARS-CoV-2 infection. Nevertheless, being a relatively new and unknown technique, the lack of trained personnel has limited its application worldwide. Computer-aided diagnosis could possibly help to reduce the learning curve for less experienced physicians, and to extend such a new technique such as lung ultrasound more quickly. This work presents the preliminary results of the ULTRACOV (Ultrasound in Coronavirus disease) study, aimed to explore the feasibility of a real-time image processing algorithm for automatic calculation of the lung ultrasound score (LUS). A total of 28 patients positive on COVID-19 were recruited and scanned in 12 thorax zones following the lung score protocol, saving a 3 s video at each probe position. Those videos were evaluated by an experienced physician and by a custom developed automated detection algorithm, looking for A-Lines, B-Lines, consolidations, and pleural effusions. The agreement between the findings of the expert and the algorithm was 88.0% for B-Lines, 93.4% for consolidations and 99.7% for pleural effusion detection, and 72.8% for the individual video score. The standard deviation of the patient lung score difference between the expert and the algorithm was ±2.2 points over 36. The exam average time with the ULTRACOV prototype was 5.3 min, while with a conventional scanner was 12.6 min. Conclusion: A good agreement between the algorithm output and an experienced physician was observed, which is a first step on the feasibility of developing a real-time aided-diagnosis lung ultrasound equipment. Additionally, the examination time was reduced to less than half with regard to a conventional ultrasound exam. Acquiring a complete lung ultrasound exam within a few minutes is possible using fairly simple ultrasound machines that are enhanced with artificial intelligence, such as the one we propose. This step is critical to democratize the use of lung ultrasound in these difficult times.