Qi Haiming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qi Haiming has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Baojun Ge
Harbin University of Science and Technology, Harbin, China
3 shared publications - Jichao Han
Harbin University of Science and Technology
3 shared publications Bian Xizhao
School of electrical and electronic engineering, Harbin University of Science and Technology, Harbin, China
1 shared publication- Dong Jiechen
Harbin University of Science and Technology, Harbin 150080, China
1 shared publication Dongxin Guo
School of Electrical and Electronic Engineering, North China Electric Power University, Beijing, China
1 shared publication- Guopei Zhang
Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, School of Electrical Engineering, Shandong University, Jinan, China
1 shared publication
Latest Publications
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 53-62
Coupled Magneto-Thermal Analysis of Spoke-Type Interior Permanent Magnet Synchronous Motor Under the Overload Condition Considering PM Demagnetization
The spoke-type interior permanent magnet synchronous motor (STIPMSM) is used in the drive systems of electric heavy-duty truck. The drive motors are prone to the overload operation when the electric heavy-duty truck climbs a slope or operates under the heavy load. The reliability of motor is a challenge. The sustained overload capacity is an important index of STIPMSM performance. An improved multi-objective nonlinear coupled iterative calculation method for STIPMSM is proposed, which can accurately calculate the performance changes of STIPMSM under different overload conditions. The nonlinearity of the magnetic circuit and the influence of the external conditions on the material performance are considered in this method. A 650kW STIPMSM is studied. The multi-objective nonlinear coupled iterative calculation method is applied to calculate the different overload conditions. The final multi-objective convergence of physical quantities is achieved. The change of electromagnetic field and harmonics is analyzed under different load rates. A method based on nonlinear fitting for maximum sustained overload (MSO) prediction of STIPMSM is proposed. The predicted MSO operating conditions are calculated. The calculated results are agreement with the predicted results. Experiments are conducted on the STIPMSM prototype under different operating conditions. The accuracy of the calculation method is verified.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 53-62
Coupled Magneto-Thermal Analysis of Spoke-Type Interior Permanent Magnet Synchronous Motor Under the Overload Condition Considering PM Demagnetization
The spoke-type interior permanent magnet synchronous motor (STIPMSM) is used in the drive systems of electric heavy-duty truck. The drive motors are prone to the overload operation when the electric heavy-duty truck climbs a slope or operates under the heavy load. The reliability of motor is a challenge. The sustained overload capacity is an important index of STIPMSM performance. An improved multi-objective nonlinear coupled iterative calculation method for STIPMSM is proposed, which can accurately calculate the performance changes of STIPMSM under different overload conditions. The nonlinearity of the magnetic circuit and the influence of the external conditions on the material performance are considered in this method. A 650kW STIPMSM is studied. The multi-objective nonlinear coupled iterative calculation method is applied to calculate the different overload conditions. The final multi-objective convergence of physical quantities is achieved. The change of electromagnetic field and harmonics is analyzed under different load rates. A method based on nonlinear fitting for maximum sustained overload (MSO) prediction of STIPMSM is proposed. The predicted MSO operating conditions are calculated. The calculated results are agreement with the predicted results. Experiments are conducted on the STIPMSM prototype under different operating conditions. The accuracy of the calculation method is verified.
- Open Access
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 53624-53633
Influence of Different Control Parameters on the Flux Density and Loss of Stator Core in the Switched Reluctance Motor
Switched reluctance motor has the advantages of the high efficiency, low cost, strong fault tolerance, and high reliability. A 5.5 kW, 12/8 pole switched reluctance motor is designed. The novel transient electromagnetic field-control circuit coupled calculation method of switched reluctance motor is proposed. The influence of different PWM switching angles, chopping current thresholds, and hysteresis current widths on flux density and loss of stator core in the switched reluctance motor is studied in detailed by this novel method. Controller harmonics are considered during this calculation. The change of the flux density and loss of stator core in the switched reluctance motor is compared and analyzed under the different controller parameters. The reliability of the calculation method and accuracy of the calculation results are verified by experimental values.
- 29 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 53624-53633
Open AccessInfluence of Different Control Parameters on the Flux Density and Loss of Stator Core in the Switched Reluctance Motor
Switched reluctance motor has the advantages of the high efficiency, low cost, strong fault tolerance, and high reliability. A 5.5 kW, 12/8 pole switched reluctance motor is designed. The novel transient electromagnetic field-control circuit coupled calculation method of switched reluctance motor is proposed. The influence of different PWM switching angles, chopping current thresholds, and hysteresis current widths on flux density and loss of stator core in the switched reluctance motor is studied in detailed by this novel method. Controller harmonics are considered during this calculation. The change of the flux density and loss of stator core in the switched reluctance motor is compared and analyzed under the different controller parameters. The reliability of the calculation method and accuracy of the calculation results are verified by experimental values.
- Open Access
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 3252-3262
Influence of Complex Fluid Flow on Temperature Distribution in the Rotor Region of Large Hydrogenerator Under the Rotor Rotation
Ventilation cooling design is one of the key technologies during the design of large hydrogenerator. With the increase of hydrogenerator capacity, the overheating problem of rotor region become more and more serious. In this paper, a 250 MW hydrogenerator is analyzed. The transient electromagnetic field of the hydrogenerator is calculated. The losses (heat sources) of rotor components in the rotor region of the hydrogenerator are determined. Three-dimensional fluid and thermal coupled mathematic model of the hydrogenerator rotor region is established. The rotor rotation of the hydrogenerator is considered. The distribution of complex fluid velocity in the rotor region is calculated using the finite volume method. The influence of fluid velocity in the different directions on the temperature of the rotor excitation winding is studied under the different flow rates in the rotor region. The surface heat-transfer coefficient distribution of the rotor components is determined. The temperature distribution of the rotor excitation winding, rotor pole body, rotor press plate, rotor damping bar, and rotor end ring is obtained. The calculated temperature results match well with test values. These provide an important reference for the rotor structural design and optimization of larger hydrogenerator.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 3252-3262
Open AccessInfluence of Complex Fluid Flow on Temperature Distribution in the Rotor Region of Large Hydrogenerator Under the Rotor Rotation
Ventilation cooling design is one of the key technologies during the design of large hydrogenerator. With the increase of hydrogenerator capacity, the overheating problem of rotor region become more and more serious. In this paper, a 250 MW hydrogenerator is analyzed. The transient electromagnetic field of the hydrogenerator is calculated. The losses (heat sources) of rotor components in the rotor region of the hydrogenerator are determined. Three-dimensional fluid and thermal coupled mathematic model of the hydrogenerator rotor region is established. The rotor rotation of the hydrogenerator is considered. The distribution of complex fluid velocity in the rotor region is calculated using the finite volume method. The influence of fluid velocity in the different directions on the temperature of the rotor excitation winding is studied under the different flow rates in the rotor region. The surface heat-transfer coefficient distribution of the rotor components is determined. The temperature distribution of the rotor excitation winding, rotor pole body, rotor press plate, rotor damping bar, and rotor end ring is obtained. The calculated temperature results match well with test values. These provide an important reference for the rotor structural design and optimization of larger hydrogenerator.
- 2 July 2010
- Published by Pleiades Publishing Ltd in Laser Physics
- Vol. 20 (8) , 1692-1694
Passively Q-switched and mode-locked 1.3 μm Nd:YAG laser with Co:LMA saturable absorber
An xenon-lamp-pumped passively Q-switched and mode-locked (QML) Nd:YAG laser with Co:LMA saturable absorber at 1.3 μm is realized in a straight cavity. The modulation depth of mode locking pulse has reached 100%. The pulse energy and the pulse width of QML laser have been measured. The pulse width of the mode-locking laser is estamated to be 940 ps.
- 2 July 2010
- Published by Pleiades Publishing Ltd in Laser Physics
- Vol. 20 (8) , 1692-1694
Passively Q-switched and mode-locked 1.3 μm Nd:YAG laser with Co:LMA saturable absorber
An xenon-lamp-pumped passively Q-switched and mode-locked (QML) Nd:YAG laser with Co:LMA saturable absorber at 1.3 μm is realized in a straight cavity. The modulation depth of mode locking pulse has reached 100%. The pulse energy and the pulse width of QML laser have been measured. The pulse width of the mode-locking laser is estamated to be 940 ps.