Luis Balbino Caurcel-Díaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luis Balbino Caurcel-Díaz has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Gonzalo García de Casasola Sánchez
Department of Internal Medicine, Fundación Alcorcón University Hospital, Madrid, Spain
2 shared publications - Marta Torres-Arrese
Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Madrid, Spain
2 shared publications - Yale Tung-Chen
Department of Internal Medicine, Hospital Universitario La Paz, Paseo Castellana 241, 28046 Madrid, Spain
2 shared publications - Alma Elena Real Martín
Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
1 shared publication - Arantzazu Mata-Martínez
Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
1 shared publication - Begoña Gonzalo Moreno
Department of Emergency Medicine, Hospital Universitario Fundación de Alcorcón, Calle Budapest 1, 28922 Alcorcón, Spain
1 shared publication
Latest Publications
- Open Access
- 4 June 2024
- Published by MDPI AG in Preprints.org
The Cardiac Pulsed Wave Doppler Pattern of the Common Femoral Vein in the Diagnosis of the Likelihood of Severe Pulmonary Hypertension: Results from a Prospective, Multicen-Tric Study
Background and Objectives: Pulmonary Hypertension (PH) is a clinical condition with high mortality rates, particularly in patients over 65. Current guidelines recommend assessing the Probability of Pulmonary Hypertension (PHP) using advanced echocardiography, before pro-ceeding to right heart catheterization. This study proposes using the common femoral vein (CFV), an accessible vein that reflects right atrial pressure, as an alternative method to assess the like-lihood of severe PHP. Materials and Methods: This prospective observational study included 175 emergency patients from three hospitals. Ultrasound assessed the Pulsed Wave Doppler (PW-Doppler) morphology of the CFV. This diagnostic yield for high PHP was evaluated along-side traditional ultrasound parameters (right-to-left ventricular basal diameter ratio greater than 1 (RV>LV), septal flattening, right ventricular outflow acceleration time of less than 105 ms and/or mesosystolic notching, pulmonary artery diameter greater than the aortic root diameter or over 25 mm, early pulmonary regurgitation maximum velocity >2.2 m/s, TAPSE/PASP less than 0.55, in-ferior vena cava (IVC) diameter over 21 mm with decreased inspiratory collapse, and right atrial (RA) area over 18 cm²). Results: The CFV's PW-Doppler cardiac pattern correlated strongly with high PHP, showing a sensitivity (Sn) of 72% and a specificity (Sp) of 96%. RA dilation and TAPSE/PASP < 0.55 also played significant diagnostic roles. Conclusions: The CFV's PW-Doppler cardiac pattern is an effective indicator of high PHP, allowing reliable exclusion of this condition when absent. This approach could simplify initial PHP evaluation in emergency settings or where echocardiographic resources are limited.
- 4 June 2024
- Published by MDPI AG in Preprints.org
Open AccessThe Cardiac Pulsed Wave Doppler Pattern of the Common Femoral Vein in the Diagnosis of the Likelihood of Severe Pulmonary Hypertension: Results from a Prospective, Multicen-Tric Study
Background and Objectives: Pulmonary Hypertension (PH) is a clinical condition with high mortality rates, particularly in patients over 65. Current guidelines recommend assessing the Probability of Pulmonary Hypertension (PHP) using advanced echocardiography, before pro-ceeding to right heart catheterization. This study proposes using the common femoral vein (CFV), an accessible vein that reflects right atrial pressure, as an alternative method to assess the like-lihood of severe PHP. Materials and Methods: This prospective observational study included 175 emergency patients from three hospitals. Ultrasound assessed the Pulsed Wave Doppler (PW-Doppler) morphology of the CFV. This diagnostic yield for high PHP was evaluated along-side traditional ultrasound parameters (right-to-left ventricular basal diameter ratio greater than 1 (RV>LV), septal flattening, right ventricular outflow acceleration time of less than 105 ms and/or mesosystolic notching, pulmonary artery diameter greater than the aortic root diameter or over 25 mm, early pulmonary regurgitation maximum velocity >2.2 m/s, TAPSE/PASP less than 0.55, in-ferior vena cava (IVC) diameter over 21 mm with decreased inspiratory collapse, and right atrial (RA) area over 18 cm²). Results: The CFV's PW-Doppler cardiac pattern correlated strongly with high PHP, showing a sensitivity (Sn) of 72% and a specificity (Sp) of 96%. RA dilation and TAPSE/PASP < 0.55 also played significant diagnostic roles. Conclusions: The CFV's PW-Doppler cardiac pattern is an effective indicator of high PHP, allowing reliable exclusion of this condition when absent. This approach could simplify initial PHP evaluation in emergency settings or where echocardiographic resources are limited.
- Open Access
Usefulness of Serial Multiorgan Point-of-Care Ultrasound in Acute Heart Failure: Results from a Prospective Observational Cohort
Background and Objectives: Acute heart failure (AHF) is a common disease and a cause of high morbidity and mortality, constituting a major health problem. The main purpose of this study was to determine the impact of multiorgan ultrasound in identifying pulmonary hypertension (PH), a major prognostic factor in patients admitted due to AHF, and assess whether there are significant changes in the venous excess ultrasonography (VE × US) score or femoral vein Doppler at discharge. Materials and Methods: Patients were evaluated with a standard protocol of lung ultrasound, echocardiography, inferior vena cava (IVC) and hepatic, portal, intra-renal and femoral vein Doppler flow patterns at admission and on the day of discharge. Results: Thirty patients were enrolled during November 2021. The mean age was seventy-nine years (Standard Deviation–SD 13.4). Seven patients (23.3%) had a worsening renal function during hospitalization. Regarding ultrasound findings, VE × US score was calculated at admission and at discharge, unexpectedly remaining unchanged or even worsened (21 patients, 70.0%). The area under the curve for the lung score was 83.9% (p = 0.008), obtaining a cutoff value of 10 that showed a sensitivity of 82.6% and a specificity of 71.4% in the identification of intermediate and high PH. It was possible to monitor significant changes between both exams on the lung score (16.5 vs. 9.3; p < 0.001), improvement in the hepatic vein Doppler pattern (2.4 vs. 2.1; p = 0.002), improvement in portal vein Doppler pattern (1.7 vs. 1.4; p = 0.023), without significant changes in the intra-renal vein Doppler pattern (1.70 vs. 1.57; p = 0.293), VE × US score (1.3 vs. 1.1; p = 0.501), femoral vein Doppler pattern (2.4 vs. 2.1; p = 0.161) and IVC collapsibility (2.0 vs. 2.1; p = 0.420). Conclusions: Our study results suggest that performing serial multiorgan Point-of-Care ultrasound can help us to better identify high and intermediate probability of PH patients with AHF. Currently proposed multi-organ, venous Doppler scanning protocols, such as the VE × US score, should be further studied before expanding its use in AHF patients.
Open AccessUsefulness of Serial Multiorgan Point-of-Care Ultrasound in Acute Heart Failure: Results from a Prospective Observational Cohort
Background and Objectives: Acute heart failure (AHF) is a common disease and a cause of high morbidity and mortality, constituting a major health problem. The main purpose of this study was to determine the impact of multiorgan ultrasound in identifying pulmonary hypertension (PH), a major prognostic factor in patients admitted due to AHF, and assess whether there are significant changes in the venous excess ultrasonography (VE × US) score or femoral vein Doppler at discharge. Materials and Methods: Patients were evaluated with a standard protocol of lung ultrasound, echocardiography, inferior vena cava (IVC) and hepatic, portal, intra-renal and femoral vein Doppler flow patterns at admission and on the day of discharge. Results: Thirty patients were enrolled during November 2021. The mean age was seventy-nine years (Standard Deviation–SD 13.4). Seven patients (23.3%) had a worsening renal function during hospitalization. Regarding ultrasound findings, VE × US score was calculated at admission and at discharge, unexpectedly remaining unchanged or even worsened (21 patients, 70.0%). The area under the curve for the lung score was 83.9% (p = 0.008), obtaining a cutoff value of 10 that showed a sensitivity of 82.6% and a specificity of 71.4% in the identification of intermediate and high PH. It was possible to monitor significant changes between both exams on the lung score (16.5 vs. 9.3; p < 0.001), improvement in the hepatic vein Doppler pattern (2.4 vs. 2.1; p = 0.002), improvement in portal vein Doppler pattern (1.7 vs. 1.4; p = 0.023), without significant changes in the intra-renal vein Doppler pattern (1.70 vs. 1.57; p = 0.293), VE × US score (1.3 vs. 1.1; p = 0.501), femoral vein Doppler pattern (2.4 vs. 2.1; p = 0.161) and IVC collapsibility (2.0 vs. 2.1; p = 0.420). Conclusions: Our study results suggest that performing serial multiorgan Point-of-Care ultrasound can help us to better identify high and intermediate probability of PH patients with AHF. Currently proposed multi-organ, venous Doppler scanning protocols, such as the VE × US score, should be further studied before expanding its use in AHF patients.