YSYu Shen

Yu Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu Shen has a total of 82 co-authors. Here are the top co-authors by number of shared publications:

  • Yong Bo

    Technical Institute of Physics and Chemistryhttps://ror.org/04akaak77, Chinese Academy of Sciences, Beijing 100190, China

    10 shared publications
  • Nan Zong

    Key Lab of Solid State Laser, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China

    6 shared publications
  • Qin-Jun Peng

    Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China

    5 shared publications
  • Qinjun Peng

    Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Solid State Laser, Beijing, Peoples R China

    5 shared publications
  • Jin-Quan Chang

    Key Lab of Solid State Laser, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China

    4 shared publications
  • Qin-Jun Peng

    Technical Institute of Physics and Chemistryhttps://ror.org/04akaak77, Chinese Academy of Sciences, Beijing 100190, China

    4 shared publications

Latest Publications

  • Ultrabroad tunable (4.5–15 µm) high-energy, high-power picosecond optical parametric oscillator in BGSe crystal

    by You Fang, Yu Shen, Er-Peng Wang, Yue Xiong, Ya Wen, Xing-Yue Wang, Kai Song, Ji-Yong Yao, Shen-Jin Zhang, Zhong-Zheng Chen, et al.

    We demonstrate the first, to the best of our knowledge, ultrabroad tunable (4.5–15 μm) mid-infrared (MIR) synchronously pumped optical parametric oscillator (SPOPO) based on BaGa 4 Se 7 (BGSe) crystal. Pumped by a burst-mode picosecond 1.064 μm MOPA with 10 sub-pulses, the SPOPO achieves continuous tuning from 4.5 to 15 μm. The average output power exceeds 100 mW over 5.5–11 μm, reaching a maximum of 213.9 mW at 5.7 μm, corresponding to a burst energy of 107 μJ and an average single pulse energy of 13.4 μJ. The quantum efficiency surpasses 20% over 5.2–12 μm and peaks at 34.5% at 7.8 μm. This represents the widest tuning range and the first >100 mW average power in the >8 μm region for an MIR SPOPO. These results highlight the potential of few-pulse burst-mode-pumped SPOPOs for generating widely tunable, high-energy, high-power ultrashort pulses, offering an excellent ultrafast source for MIR applications.

  • Open Access

    High-Efficiency, 10-Watt-Level 6.45 µm Mid-Infrared Source Based on a ZnGeP2 Optical Parametric Oscillator

    by You Fang, Yu Shen, Erpeng Wang, Ya Wen, Guanghe Li, Yiming Liang, Shenjin Zhang, Zhongzheng Chen, Yong Bo, Qinjun Peng, et al.

    The 6.45 μm mid-infrared laser is highly promising for medical applications due to its efficient tissue ablation with minimal collateral damage. In this work, we demonstrate a stable and compact 10W-level, all-solid-state nanosecond laser source at 6.45 μm based on a Ho:YAG MOPA pumped ring-cavity ZnGeP2 optical parametric oscillator (ZGP OPO). The influence of spot size, phase-matching scheme, and crystal length on the output performance was systematically investigated. Using a 30 mm long Type I ZGP crystal, the system achieved optimal performance: a record-high average output power of 14.6 W at 6.45 μm with an optical-to-optical conversion efficiency of 17.57%, a peak power of 51.7 kW, and excellent power stability (1.45% fluctuation over 120 min at 11.7 W). To our knowledge, this represents the highest reported output power and conversion efficiency for an OPO in this spectral region, surpassing previous sources by an order of magnitude in average power and showing nearly double efficiency. This work provides a stable and reliable laser source tool for application research for techniques such as laser ablation.


  • Infrared-driven topochemical reaction of a diacetylene

    by Xingyue Wang, Zidi Yan, Dailong Liu, Huajing Yuan, Xuehua Song, You Fang, Yue Long, Yu Shen, Kai Song

    The ordered, confined aggregates in DA-17 undergo efficient topochemical oligomerization under broadband mid-infrared excitation, with the reaction rate enhanced approximately 14-fold relative to that under thermal activation.

  • High power, high beam quality and narrow linewidth diode-end-pumped Nd:YAG seed laser at 1319 nm for a sodium guide star laser system

    by Yu Shen, Ning Wen, Ya Wen, Hongwei Gao, Qi Bian, Yong Bo, Qinjun Peng

    A high power, high beam quality and narrow linewidth Nd:YAG 1319 nm pulsed seed laser for sodium beacon is demonstrated, which was dual-end-pumped by the low quantum loss 885 nm quasi-continuous wave laser diodes (LDs). The resonator was based on a ring convex–convex structure with a dual-rod configuration. Adjusting the effective pump size in the crystal and the temperature of the LDs to realize the optimal size ratio of the pump beam and laser mode was analyzed finely. An output power of up to 25 W at 1319 nm has been obtained, operating at 800 Hz with a pulse duration of 140 μs, corresponding to a high optical-to-optical conversion efficiency of 18%. The average beam quality factor of M 2 was measured to be 1.25. To the best of our knowledge, this is both the highest output power and the highest beam quality at 1319 nm for the 885 nm LDs end-pumped with the pulse oscillator. This result provides a 1319 nm seed laser for a sodium guide star laser system, with high quality (high power, high beam quality and narrow linewidth), and also better stability.

  • Open Access

    Investigation and comparison on the interaction of laser and bio-tissue based on two classical models, the beam broaden model and diffusion approximation equation model, theoretically and experimentally

    by Yuru Cheng, Yu Shen, Yuxia Gao, Ya Wen, Ze Lv, Ning Wen, Erpeng Wang, Guanghe Li, Yong Bo, Qinjun Peng

    Three methods are used for a numerical solution, the Monte Carlo method, diffusion approximation equation model, and beam broaden model based on Beer–Lambert’s law equation. The comparison between the first two methods is reported theoretically, and the latter is a better choice in the high-density tissue. However, the comparison between the third method and the first or the second method is rarely reported. Two classical theoretical models describing the interaction between the laser and the bio-tissue are analyzed and compared to determine which is more suitable for analyzing the interaction, the beam broaden model or diffusion approximation equation model. Intensity distribution is simulated and compared for the two models. Temperature distribution and thermal damage are investigated theoretically and experimentally for both models. The differences and the reasons are analyzed. The diffusion approximation equation model is more suitable for analyzing the mechanism between the laser and the bio-tissue based on the degree of fitting between the simulated and experimental data. Theoretical analyses for the two models are carried out in detail. The comparison between the two models is rarely reported, and it is reported in this article for the first time, theoretically and experimentally. This report provides a better choice for quickly analyzing the interaction mechanism between the laser and the bio-tissue.


  • Open Access

    Theoretical and Experimental Analysis of the Effect of Vaporization Heat on the Interaction between Laser and Biological Tissue

    by Yuru Cheng, Yu Shen, Yuxia Gao, Ya Wen, Ze Lv, Erpeng Wang, Mingli Wang, Shenjin Zhang, Yong Bo, Qinjun Peng

    A theoretical model, based on the classical Pennes’ bioheat theory, incorporating various boundary conditions, was established and compared to analyze the influence of the latent heat of vaporization via simulation. The aim was to elucidate the extent of its influence. The thermal damage rate, governed by the vaporization heat of biological tissue, is introduced as a key factor. Functional relationships between temperature and incident laser power, spatial position, and time are derived from the classical Pennes’ bioheat equation. According to the theoretical model, numerical simulations and experimental validations are conducted using Comsol Multiphysics 6.0, considering the tissue latent heat of vaporization. The model incorporating the latent heat of vaporization proved more suitable for analyzing the interactions between laser and biological tissue, evident from the degree of fit between simulated and experimental data. The minimum deviations between theoretical and experimental observations were determined to be 2.43% and 5.11% in temperature and thermal damage, respectively. Furthermore, this model can be extended to facilitate the theoretical analysis of the impact of vaporization heat from different primary tissue components on laser-tissue interaction.


  • Open Access

    2.85-kW cryogenic Nd:YAG slab laser operating at 946 nm

    by Jin-Quan Chang, Qi Bian, Yong Bo, Yu Shen, Qin-Jun Peng

    A several-kilowatt level laser at 946 nm is demonstrated in a cryogenically cooled diode-pumped Nd:YAG slab system. The oscillator realizes the record of the output power of 2.85 kW in a compact cavity with the homemade cryogenically cooled Nd:YAG crystal slab. The pulse repetition rate and pulse width of the laser are 400 Hz and 200 µs, respectively, and the center wavelength under full power is 946.2 nm with a bandwidth of about 0.5 nm. The absorption linewidth at 808 nm is a little narrowed and blue shifts at the cryogenic temperature, while the cooling temperature decreases from 300 to 77 K. The measured thermal conductivity increases from 10 to 70 W/mˑK, and the thermal expansion coefficient decreases from 7.5*10−6 to 1.5*10−6/K. These results could guide us in simulating the temperature gradient and thermal-induced stress distributions in the crystal slab.


  • Open Access

    A Stable and Compact Mid-IR at 6.45 μm Exceeding 6 mJ of Pulse Energy BaGa4Se7 Optical Parametric Oscillator

    by Ning Wen, Yu Shen, Ya Wen, Erpeng Wang, Jiyong Yao, You Fang, Hongwei Gao, Yong Bo, Zhongzheng Chen, Qinjun Peng

    We experimentally demonstrate a stable and compact high pulse energy mid-infrared (MIR) 6.45 μm laser, which is produced by an optical parametric oscillator (OPO) based on the non-oxide BaGa4Se7 (BGSe) nonlinear crystal pumped by 1064 nm Nd:YAG laser oscillator. With optimizing the parameters of the OPO system, a record high idler energy of 6.76 mJ at 6.45 μm was obtained with 18.85 ns of pulse duration (FWHM) at the repetition rate of 10 Hz under 93.5 mJ of pump energy, corresponding to an optical-to-optical conversion efficiency up to 7.23% from 1064 nm to 6.45 μm. The experimental results were in close approximation with the theoretical calculations. To date, it is both the highest MIR pulse energy and the highest conversion efficiency at 6.45 μm for any 1 μm pumped OPOs. Further, excellent output energy stability is demonstrated, with an energy fluctuation of less than ±0.5% over 165 min. Such a laser is interesting for both scientific and medical applications, including, for instance, for trace gas analysis and tissue ablation.


  • Open Access

    An exceed 60% efficiency Nd:YAG transparent ceramic laser with low attenuation loss effect

    by Jin-Quan Chang, Yu Shen, Qi Bian, Nan Zong, Ze Lv, Yong Bo, Qin-Jun Peng

    Here, the attenuation loss effect and laser performance enhancement of Nd:YAG transparent ceramics were investigated. Using a 0.6 at.% Nd:YAG ceramic rod of 3 mm diameter and 65 mm length, the scattering coefficient and absorption coefficient at 1,064 nm were measured to be 0.0001 cm−1 and 0.0017 cm−1, respectively. For the 808-nm side-pumped laser experiment, an average output power of 44.9 W was achieved with an optical-to-optical conversion efficiency of 26.4%, which was nearly the same with that of a 1 at% single crystal. Adopting the 885-nm direct end-pumped scheme, the following laser tests demonstrated a high optical efficiency of 62.5% and maximum output power of 144.8 W obtained at an absorbed pump power of 231.5 W. This was until now the highest optical conversion efficiency acquired in an Nd:YAG ceramic laser to our knowledge. It proves that high-power and high-efficiency laser output could be generated by a high-optical quality Nd:YAG ceramic rod along with the 885-nm direct pumping technology.


  • Open Access

    High Pulse Energy, Narrow Linewidth 6.45 μm from an Optical Parametric Oscillator in BaGa4Se7 Crystal

    by Yu Shen, Ning Wen, Chunxiao Li, Nan Zong, Jiyong Yao, Jinquan Chang, Ya Wen, Feng Yang, Wenlong Li, Hongwei Gao, et al.

    This paper presents a high pulse energy, narrow linewidth, mid-infrared (MIR) laser at 6.45 μm, based on a BaGa4Se7 (BGSe) crystal optical parametric oscillator (OPO) pumped by 1.064 μm laser. The maximum pulse energy at 6.45 μm was up to 1.23 mJ, with a pulse width of 24.3 ns and repetition rate of 10 Hz, corresponding to an optical–optical conversion efficiency of 2.1%, from pump light 1.064 μm to idler light 6.45 μm. The idler light linewidth was about 6.8 nm. Meanwhile, we accurately calculated the OPO phase-matching condition at BGSe crystal pumped by 1.064 μm laser, and a numerical simulation system was performed to analyze the input–output characteristics at 6.45 μm, as well as the effect of crystal length on the conversion efficiency. Good agreement was found between measurement and simulation. To the best of our knowledge, this is the highest pulse energy at 6.45 μm, with the narrowest linewidth for any all-solid-state MIR ns laser in BGSe-OPO pumped by simple 1.064 μm oscillator. This simple and compact 6.45 μm OPO system, with high pulse energy and narrow linewidth, can meet the requirements for tissue cutting and improve tissue ablation accuracy.