Qin-Jun Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qin-Jun Peng has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Yu Shen
Technical Institute of Physics and Chemistryhttps://ror.org/04akaak77, Chinese Academy of Sciences, Beijing 100190, China
5 shared publications - Yong Bo
Chinese Academy of Sciences
4 shared publications - Erpeng Wang
Institute of Optical Physics & Engineering Technology, Qilu Zhongke, Jinan 250103, China
3 shared publications - Hong-Wei Gao
Key Laboratory of Solid State Laser, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China
3 shared publications - Qi Bian
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
3 shared publications - Ya Wen
Institute of Optical Physics & Engineering Technology, Qilu Zhongke, Jinan 250103, China
3 shared publications
Latest Publications
- Open Access
High-Efficiency, 10-Watt-Level 6.45 µm Mid-Infrared Source Based on a ZnGeP2 Optical Parametric Oscillator
The 6.45 μm mid-infrared laser is highly promising for medical applications due to its efficient tissue ablation with minimal collateral damage. In this work, we demonstrate a stable and compact 10W-level, all-solid-state nanosecond laser source at 6.45 μm based on a Ho:YAG MOPA pumped ring-cavity ZnGeP2 optical parametric oscillator (ZGP OPO). The influence of spot size, phase-matching scheme, and crystal length on the output performance was systematically investigated. Using a 30 mm long Type I ZGP crystal, the system achieved optimal performance: a record-high average output power of 14.6 W at 6.45 μm with an optical-to-optical conversion efficiency of 17.57%, a peak power of 51.7 kW, and excellent power stability (1.45% fluctuation over 120 min at 11.7 W). To our knowledge, this represents the highest reported output power and conversion efficiency for an OPO in this spectral region, surpassing previous sources by an order of magnitude in average power and showing nearly double efficiency. This work provides a stable and reliable laser source tool for application research for techniques such as laser ablation.
Open AccessHigh-Efficiency, 10-Watt-Level 6.45 µm Mid-Infrared Source Based on a ZnGeP2 Optical Parametric Oscillator
The 6.45 μm mid-infrared laser is highly promising for medical applications due to its efficient tissue ablation with minimal collateral damage. In this work, we demonstrate a stable and compact 10W-level, all-solid-state nanosecond laser source at 6.45 μm based on a Ho:YAG MOPA pumped ring-cavity ZnGeP2 optical parametric oscillator (ZGP OPO). The influence of spot size, phase-matching scheme, and crystal length on the output performance was systematically investigated. Using a 30 mm long Type I ZGP crystal, the system achieved optimal performance: a record-high average output power of 14.6 W at 6.45 μm with an optical-to-optical conversion efficiency of 17.57%, a peak power of 51.7 kW, and excellent power stability (1.45% fluctuation over 120 min at 11.7 W). To our knowledge, this represents the highest reported output power and conversion efficiency for an OPO in this spectral region, surpassing previous sources by an order of magnitude in average power and showing nearly double efficiency. This work provides a stable and reliable laser source tool for application research for techniques such as laser ablation.
- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (20) , 1229-1232
Widely Tunable BaGa2GeSe6 Optical Parametric Amplifier Pumped by a Mode-Locked Nd: YAG Laser
Powerful and compact coherent mid-infrared radiation source is crucial for a vast number of applications. A widely tunable 3-$15~\mu $ m optical parametric amplifier with BaGa2GeSe6 crystal pumped by a picosecond mode-locked 1064 nm laser was demonstrated for the first time. Type-I produced a maximum energy of$377~\mu $ J at$5.2~\mu $ m, while type-II achieved a maximum energy of$294~\mu $ J at$6.7~\mu $ m under the incident pump energy of 11.8 mJ, corresponding to the pump-to-idler energy efficiency of 3.2% and 2.5%, respectively. Furthermore, the corresponding phase-matching angles for 3–$15~\mu $ m were measured experimentally. Moreover, the conversion efficiency, typical pulse temporal shapes and beam spatial profiles of idler were calculated based on a BaGa2GeSe6-OPA numerical model. The results indicate the potential of BaGa2GeSe6 pumped at 1064 nm for realizing high-efficiency and high-energy mid-infrared laser radiation.- 11 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 36 (20) , 1229-1232
Widely Tunable BaGa2GeSe6 Optical Parametric Amplifier Pumped by a Mode-Locked Nd: YAG Laser
Powerful and compact coherent mid-infrared radiation source is crucial for a vast number of applications. A widely tunable 3-$15~\mu $ m optical parametric amplifier with BaGa2GeSe6 crystal pumped by a picosecond mode-locked 1064 nm laser was demonstrated for the first time. Type-I produced a maximum energy of$377~\mu $ J at$5.2~\mu $ m, while type-II achieved a maximum energy of$294~\mu $ J at$6.7~\mu $ m under the incident pump energy of 11.8 mJ, corresponding to the pump-to-idler energy efficiency of 3.2% and 2.5%, respectively. Furthermore, the corresponding phase-matching angles for 3–$15~\mu $ m were measured experimentally. Moreover, the conversion efficiency, typical pulse temporal shapes and beam spatial profiles of idler were calculated based on a BaGa2GeSe6-OPA numerical model. The results indicate the potential of BaGa2GeSe6 pumped at 1064 nm for realizing high-efficiency and high-energy mid-infrared laser radiation.- Open Access
- 20 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4333
Theoretical and Experimental Analysis of the Effect of Vaporization Heat on the Interaction between Laser and Biological Tissue
A theoretical model, based on the classical Pennes’ bioheat theory, incorporating various boundary conditions, was established and compared to analyze the influence of the latent heat of vaporization via simulation. The aim was to elucidate the extent of its influence. The thermal damage rate, governed by the vaporization heat of biological tissue, is introduced as a key factor. Functional relationships between temperature and incident laser power, spatial position, and time are derived from the classical Pennes’ bioheat equation. According to the theoretical model, numerical simulations and experimental validations are conducted using Comsol Multiphysics 6.0, considering the tissue latent heat of vaporization. The model incorporating the latent heat of vaporization proved more suitable for analyzing the interactions between laser and biological tissue, evident from the degree of fit between simulated and experimental data. The minimum deviations between theoretical and experimental observations were determined to be 2.43% and 5.11% in temperature and thermal damage, respectively. Furthermore, this model can be extended to facilitate the theoretical analysis of the impact of vaporization heat from different primary tissue components on laser-tissue interaction.
- 20 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4333
Open AccessTheoretical and Experimental Analysis of the Effect of Vaporization Heat on the Interaction between Laser and Biological Tissue
A theoretical model, based on the classical Pennes’ bioheat theory, incorporating various boundary conditions, was established and compared to analyze the influence of the latent heat of vaporization via simulation. The aim was to elucidate the extent of its influence. The thermal damage rate, governed by the vaporization heat of biological tissue, is introduced as a key factor. Functional relationships between temperature and incident laser power, spatial position, and time are derived from the classical Pennes’ bioheat equation. According to the theoretical model, numerical simulations and experimental validations are conducted using Comsol Multiphysics 6.0, considering the tissue latent heat of vaporization. The model incorporating the latent heat of vaporization proved more suitable for analyzing the interactions between laser and biological tissue, evident from the degree of fit between simulated and experimental data. The minimum deviations between theoretical and experimental observations were determined to be 2.43% and 5.11% in temperature and thermal damage, respectively. Furthermore, this model can be extended to facilitate the theoretical analysis of the impact of vaporization heat from different primary tissue components on laser-tissue interaction.
- Open Access
- 1 June 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11
2.85-kW cryogenic Nd:YAG slab laser operating at 946 nm
A several-kilowatt level laser at 946 nm is demonstrated in a cryogenically cooled diode-pumped Nd:YAG slab system. The oscillator realizes the record of the output power of 2.85 kW in a compact cavity with the homemade cryogenically cooled Nd:YAG crystal slab. The pulse repetition rate and pulse width of the laser are 400 Hz and 200 µs, respectively, and the center wavelength under full power is 946.2 nm with a bandwidth of about 0.5 nm. The absorption linewidth at 808 nm is a little narrowed and blue shifts at the cryogenic temperature, while the cooling temperature decreases from 300 to 77 K. The measured thermal conductivity increases from 10 to 70 W/mˑK, and the thermal expansion coefficient decreases from 7.5*10−6 to 1.5*10−6/K. These results could guide us in simulating the temperature gradient and thermal-induced stress distributions in the crystal slab.
- 1 June 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11
Open Access2.85-kW cryogenic Nd:YAG slab laser operating at 946 nm
A several-kilowatt level laser at 946 nm is demonstrated in a cryogenically cooled diode-pumped Nd:YAG slab system. The oscillator realizes the record of the output power of 2.85 kW in a compact cavity with the homemade cryogenically cooled Nd:YAG crystal slab. The pulse repetition rate and pulse width of the laser are 400 Hz and 200 µs, respectively, and the center wavelength under full power is 946.2 nm with a bandwidth of about 0.5 nm. The absorption linewidth at 808 nm is a little narrowed and blue shifts at the cryogenic temperature, while the cooling temperature decreases from 300 to 77 K. The measured thermal conductivity increases from 10 to 70 W/mˑK, and the thermal expansion coefficient decreases from 7.5*10−6 to 1.5*10−6/K. These results could guide us in simulating the temperature gradient and thermal-induced stress distributions in the crystal slab.
- Open Access
- 24 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6413
A Stable and Compact Mid-IR at 6.45 μm Exceeding 6 mJ of Pulse Energy BaGa4Se7 Optical Parametric Oscillator
We experimentally demonstrate a stable and compact high pulse energy mid-infrared (MIR) 6.45 μm laser, which is produced by an optical parametric oscillator (OPO) based on the non-oxide BaGa4Se7 (BGSe) nonlinear crystal pumped by 1064 nm Nd:YAG laser oscillator. With optimizing the parameters of the OPO system, a record high idler energy of 6.76 mJ at 6.45 μm was obtained with 18.85 ns of pulse duration (FWHM) at the repetition rate of 10 Hz under 93.5 mJ of pump energy, corresponding to an optical-to-optical conversion efficiency up to 7.23% from 1064 nm to 6.45 μm. The experimental results were in close approximation with the theoretical calculations. To date, it is both the highest MIR pulse energy and the highest conversion efficiency at 6.45 μm for any 1 μm pumped OPOs. Further, excellent output energy stability is demonstrated, with an energy fluctuation of less than ±0.5% over 165 min. Such a laser is interesting for both scientific and medical applications, including, for instance, for trace gas analysis and tissue ablation.
- 24 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6413
Open AccessA Stable and Compact Mid-IR at 6.45 μm Exceeding 6 mJ of Pulse Energy BaGa4Se7 Optical Parametric Oscillator
We experimentally demonstrate a stable and compact high pulse energy mid-infrared (MIR) 6.45 μm laser, which is produced by an optical parametric oscillator (OPO) based on the non-oxide BaGa4Se7 (BGSe) nonlinear crystal pumped by 1064 nm Nd:YAG laser oscillator. With optimizing the parameters of the OPO system, a record high idler energy of 6.76 mJ at 6.45 μm was obtained with 18.85 ns of pulse duration (FWHM) at the repetition rate of 10 Hz under 93.5 mJ of pump energy, corresponding to an optical-to-optical conversion efficiency up to 7.23% from 1064 nm to 6.45 μm. The experimental results were in close approximation with the theoretical calculations. To date, it is both the highest MIR pulse energy and the highest conversion efficiency at 6.45 μm for any 1 μm pumped OPOs. Further, excellent output energy stability is demonstrated, with an energy fluctuation of less than ±0.5% over 165 min. Such a laser is interesting for both scientific and medical applications, including, for instance, for trace gas analysis and tissue ablation.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 58 (6) , 1-4
High Pulse Energy 1319 nm Q-Switched Nd: YAG Laser
We describe a high-peak-power macro/micro pulse 1319 nm laser operation, which is produced by the acousto-optic Q-switched Nd:YAG oscillator that is side-pumped with quasi- continuous-wave laser diode. Under remaining a fixed macro pulse repetition frequency of 400 Hz, the lasing characteristics for different micro pulse schemes are investigated. To realize 1319 nm single wavelength oscillation, a birefringence-plate is employed to suppress the adjacent 1338 nm line. Under 390 W of pump power with $200 ~\mu \text{s}$ of pulse duration, an average Q-switched 1319 nm power is increased from 32.5 W to 51.5 W by increasing the repetition rate of micro pulse from 400 Hz to 1600 Hz, and the corresponding micro pulse width can be stretched from 124 ns to 154 ns. The calculated maximum peak power is 0.655 MW with a pulse energy of 81.2 mJ, which is the highest-result reported to date for Q-switched 1319 nm lasers.
- 12 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 58 (6) , 1-4
High Pulse Energy 1319 nm Q-Switched Nd: YAG Laser
We describe a high-peak-power macro/micro pulse 1319 nm laser operation, which is produced by the acousto-optic Q-switched Nd:YAG oscillator that is side-pumped with quasi- continuous-wave laser diode. Under remaining a fixed macro pulse repetition frequency of 400 Hz, the lasing characteristics for different micro pulse schemes are investigated. To realize 1319 nm single wavelength oscillation, a birefringence-plate is employed to suppress the adjacent 1338 nm line. Under 390 W of pump power with $200 ~\mu \text{s}$ of pulse duration, an average Q-switched 1319 nm power is increased from 32.5 W to 51.5 W by increasing the repetition rate of micro pulse from 400 Hz to 1600 Hz, and the corresponding micro pulse width can be stretched from 124 ns to 154 ns. The calculated maximum peak power is 0.655 MW with a pulse energy of 81.2 mJ, which is the highest-result reported to date for Q-switched 1319 nm lasers.
- Open Access
- 1 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (13) , 6689
High Pulse Energy, Narrow Linewidth 6.45 μm from an Optical Parametric Oscillator in BaGa4Se7 Crystal
This paper presents a high pulse energy, narrow linewidth, mid-infrared (MIR) laser at 6.45 μm, based on a BaGa4Se7 (BGSe) crystal optical parametric oscillator (OPO) pumped by 1.064 μm laser. The maximum pulse energy at 6.45 μm was up to 1.23 mJ, with a pulse width of 24.3 ns and repetition rate of 10 Hz, corresponding to an optical–optical conversion efficiency of 2.1%, from pump light 1.064 μm to idler light 6.45 μm. The idler light linewidth was about 6.8 nm. Meanwhile, we accurately calculated the OPO phase-matching condition at BGSe crystal pumped by 1.064 μm laser, and a numerical simulation system was performed to analyze the input–output characteristics at 6.45 μm, as well as the effect of crystal length on the conversion efficiency. Good agreement was found between measurement and simulation. To the best of our knowledge, this is the highest pulse energy at 6.45 μm, with the narrowest linewidth for any all-solid-state MIR ns laser in BGSe-OPO pumped by simple 1.064 μm oscillator. This simple and compact 6.45 μm OPO system, with high pulse energy and narrow linewidth, can meet the requirements for tissue cutting and improve tissue ablation accuracy.
- 1 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (13) , 6689
Open AccessHigh Pulse Energy, Narrow Linewidth 6.45 μm from an Optical Parametric Oscillator in BaGa4Se7 Crystal
This paper presents a high pulse energy, narrow linewidth, mid-infrared (MIR) laser at 6.45 μm, based on a BaGa4Se7 (BGSe) crystal optical parametric oscillator (OPO) pumped by 1.064 μm laser. The maximum pulse energy at 6.45 μm was up to 1.23 mJ, with a pulse width of 24.3 ns and repetition rate of 10 Hz, corresponding to an optical–optical conversion efficiency of 2.1%, from pump light 1.064 μm to idler light 6.45 μm. The idler light linewidth was about 6.8 nm. Meanwhile, we accurately calculated the OPO phase-matching condition at BGSe crystal pumped by 1.064 μm laser, and a numerical simulation system was performed to analyze the input–output characteristics at 6.45 μm, as well as the effect of crystal length on the conversion efficiency. Good agreement was found between measurement and simulation. To the best of our knowledge, this is the highest pulse energy at 6.45 μm, with the narrowest linewidth for any all-solid-state MIR ns laser in BGSe-OPO pumped by simple 1.064 μm oscillator. This simple and compact 6.45 μm OPO system, with high pulse energy and narrow linewidth, can meet the requirements for tissue cutting and improve tissue ablation accuracy.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (11) , 567-570
1338-nm Single Wavelength Operation of Acousto-Optic Q-Switched Nd:YAG Laser
We demonstrated a high-peak-power acousto-optic Q-switched Nd:YAG laser emitting at 1338 nm. The resonator adopted a symmetrical convex-convex cavity with a two-rod configuration, which is side-pumped by a $\mu $ s long pulse laser diode. At the beginning, the free running mode and Q-switched mode operated with single-wavelength emission at 1319 nm and dual-wavelength emission at 1319 and 1338 nm, respectively. By means of using a 8 mm-thick birefringence filter to increase the intra-cavity loss at 1319 nm, single wavelength operation of 1338 nm was achieved with spectral width of 0.31 nm. Under the pump power of 390 W, the Q-switched laser delivers 28.7 W of average output power with an optical conversion efficiency of 7.4%. The pulse width was measured to be 124 ns with a repetition rate of 400 Hz, and the corresponding peak power is up to 0.58 MW.
- 5 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 34 (11) , 567-570
1338-nm Single Wavelength Operation of Acousto-Optic Q-Switched Nd:YAG Laser
We demonstrated a high-peak-power acousto-optic Q-switched Nd:YAG laser emitting at 1338 nm. The resonator adopted a symmetrical convex-convex cavity with a two-rod configuration, which is side-pumped by a $\mu $ s long pulse laser diode. At the beginning, the free running mode and Q-switched mode operated with single-wavelength emission at 1319 nm and dual-wavelength emission at 1319 and 1338 nm, respectively. By means of using a 8 mm-thick birefringence filter to increase the intra-cavity loss at 1319 nm, single wavelength operation of 1338 nm was achieved with spectral width of 0.31 nm. Under the pump power of 390 W, the Q-switched laser delivers 28.7 W of average output power with an optical conversion efficiency of 7.4%. The pulse width was measured to be 124 ns with a repetition rate of 400 Hz, and the corresponding peak power is up to 0.58 MW.
- 30 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2898-2902
QCW surface-pumped cryogenically cooled single-slab laser with 1 kW level at 946 nm
We present a kilowatt-level quasi-continuous-wave (QCW) cryogenically cooled 946-nm slab laser oscillator for the first time, to the best of our knowledge. The laser system is based on a double-face-pumped large-size single-slab Nd:YAG design, delivering a record-high average power of 1.06 kW without additional amplification. This laser oscillator operates at repetition rate of 400 Hz with a pulse duration of 175 mu s, resulting in a single pulse energy of 2.65 J. To the best of our knowledge, these results represent the highest output power and pulse energy for any all-solid-state 946-nm laser ever reported to date. Our scheme paves a new path for the development of the compact high-power solid-state 946-nm laser. (C) 2022 Optica Publishing Group
- 30 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (10) , 2898-2902
QCW surface-pumped cryogenically cooled single-slab laser with 1 kW level at 946 nm
We present a kilowatt-level quasi-continuous-wave (QCW) cryogenically cooled 946-nm slab laser oscillator for the first time, to the best of our knowledge. The laser system is based on a double-face-pumped large-size single-slab Nd:YAG design, delivering a record-high average power of 1.06 kW without additional amplification. This laser oscillator operates at repetition rate of 400 Hz with a pulse duration of 175 mu s, resulting in a single pulse energy of 2.65 J. To the best of our knowledge, these results represent the highest output power and pulse energy for any all-solid-state 946-nm laser ever reported to date. Our scheme paves a new path for the development of the compact high-power solid-state 946-nm laser. (C) 2022 Optica Publishing Group
- 20 June 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (13) , 2467-2470
Pulse width adjustable Q-switched cavity dumped laser by rotating a quarter-wave plate and a Pockels cell
A pulse width adjustable 1064 nm -switched cavity dumped laser was realized for the first time, to the best of our knowledge, by rotating an intracavity quarter-wave plate (QWP) and a Pockels cell (PC). The pulse width adjustment range was 4.8–7.8 ns with a constant output power of 3.6 W, and it reached 4.8–13.5 ns for a lower output power of 1.3 W. The pulse width was dependent mostly on the rotating angle of the QWP and PC, but independent of the gain and pulse repetition rate.- 20 June 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (13) , 2467-2470
Pulse width adjustable Q-switched cavity dumped laser by rotating a quarter-wave plate and a Pockels cell
A pulse width adjustable 1064 nm -switched cavity dumped laser was realized for the first time, to the best of our knowledge, by rotating an intracavity quarter-wave plate (QWP) and a Pockels cell (PC). The pulse width adjustment range was 4.8–7.8 ns with a constant output power of 3.6 W, and it reached 4.8–13.5 ns for a lower output power of 1.3 W. The pulse width was dependent mostly on the rotating angle of the QWP and PC, but independent of the gain and pulse repetition rate.