Michael Wenger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael Wenger has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Annice Kim
Center for Health Policy Science and Tobacco Research RTI International Research Triangle Park, NC United States
2 shared publications - David Edward Dausch
RTI International, Morrisville, NC, United States
2 shared publications - Dorota Temple
RTI International, Morrisville, NC, United States
2 shared publications - Edward A. Preble
RTI International, Research Triangle Park, USA
2 shared publications - Hope C. Davis-Wilson
RTI International, Research Triangle Park, NC 27709, USA
2 shared publications - Howard J. Walls
RTI International, Morrisville, NC, United States
2 shared publications
Latest Publications
- Open Access
- 7 August 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e53977
Continuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study
Background: Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. Objective: In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. Methods: A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. Results: The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. Conclusions: We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- 7 August 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e53977
Open AccessContinuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study
Background: Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. Objective: In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. Methods: A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. Results: The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. Conclusions: We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- Open Access
- 27 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Continuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study (Preprint)
BACKGROUND Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. OBJECTIVE In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. METHODS A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. RESULTS The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. CONCLUSIONS We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- 27 October 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContinuous Monitoring of Heart Rate Variability in Free-Living Conditions Using Wearable Sensors: Exploratory Observational Study (Preprint)
BACKGROUND Wearable physiological monitoring devices are promising tools for remote monitoring and early detection of potential health changes of interest. The widespread adoption of such an approach across communities and over long periods of time will require an automated data platform for collecting, processing, and analyzing relevant health information. OBJECTIVE In this study, we explore prospective monitoring of individual health through an automated data collection, metrics extraction, and health anomaly analysis pipeline in free-living conditions over a continuous monitoring period of several months with a focus on viral respiratory infections, such as influenza or COVID-19. METHODS A total of 59 participants provided smartwatch data and health symptom and illness reports daily over an 8-month window. Physiological and activity data from photoplethysmography sensors, including high-resolution interbeat interval (IBI) and step counts, were uploaded directly from Garmin Fenix 6 smartwatches and processed automatically in the cloud using a stand-alone, open-source analytical engine. Health risk scores were computed based on a deviation in heart rate and heart rate variability metrics from each individual’s activity-matched baseline values, and scores exceeding a predefined threshold were checked for corresponding symptoms or illness reports. Conversely, reports of viral respiratory illnesses in health survey responses were also checked for corresponding changes in health risk scores to qualitatively assess the risk score as an indicator of acute respiratory health anomalies. RESULTS The median average percentage of sensor data provided per day indicating smartwatch wear compliance was 70%, and survey responses indicating health reporting compliance was 46%. A total of 29 elevated health risk scores were detected, of which 12 (41%) had concurrent survey data and indicated a health symptom or illness. A total of 21 influenza or COVID-19 illnesses were reported by study participants; 9 (43%) of these reports had concurrent smartwatch data, of which 6 (67%) had an increase in health risk score. CONCLUSIONS We demonstrate a protocol for data collection, extraction of heart rate and heart rate variability metrics, and prospective analysis that is compatible with near real-time health assessment using wearable sensors for continuous monitoring. The modular platform for data collection and analysis allows for a choice of different wearable sensors and algorithms. Here, we demonstrate its implementation in the collection of high-fidelity IBI data from Garmin Fenix 6 smartwatches worn by individuals in free-living conditions, and the prospective, near real-time analysis of the data, culminating in the calculation of health risk scores. To our knowledge, this study demonstrates for the first time the feasibility of measuring high-resolution heart IBI and step count using smartwatches in near real time for respiratory illness detection over a long-term monitoring period in free-living conditions.
- Open Access
- 18 January 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (1) , e30257
Identifying Electronic Nicotine Delivery System Brands and Flavors on Instagram: Natural Language Processing Analysis
Background: Electronic nicotine delivery system (ENDS) brands, such as JUUL, used social media as a key component of their marketing strategy, which led to massive sales growth from 2015 to 2018. During this time, ENDS use rapidly increased among youths and young adults, with flavored products being particularly popular among these groups. Objective: The aim of our study is to develop a named entity recognition (NER) model to identify potential emerging vaping brands and flavors from Instagram post text. NER is a natural language processing task for identifying specific types of words (entities) in text based on the characteristics of the entity and surrounding words. Methods: NER models were trained on a labeled data set of 2272 Instagram posts coded for ENDS brands and flavors. We compared three types of NER models—conditional random fields, a residual convolutional neural network, and a fine-tuned distilled bidirectional encoder representations from transformers (FTDB) network—to identify brands and flavors in Instagram posts with key model outcomes of precision, recall, and F1 scores. We used data from Nielsen scanner sales and Wikipedia to create benchmark dictionaries to determine whether brands from established ENDS brand and flavor lists were mentioned in the Instagram posts in our sample. To prevent overfitting, we performed 5-fold cross-validation and reported the mean and SD of the model validation metrics across the folds. Results: For brands, the residual convolutional neural network exhibited the highest mean precision (0.797, SD 0.084), and the FTDB exhibited the highest mean recall (0.869, SD 0.103). For flavors, the FTDB exhibited both the highest mean precision (0.860, SD 0.055) and recall (0.801, SD 0.091). All NER models outperformed the benchmark brand and flavor dictionary look-ups on mean precision, recall, and F1. Comparing between the benchmark brand lists, the larger Wikipedia list outperformed the Nielsen list in both precision and recall. Conclusions: Our findings suggest that NER models correctly identified ENDS brands and flavors in Instagram posts at rates competitive with, or better than, others in the published literature. Brands identified during manual annotation showed little overlap with those in Nielsen scanner data, suggesting that NER models may capture emerging brands with limited sales and distribution. NER models address the challenges of manual brand identification and can be used to support future infodemiology and infoveillance studies. Brands identified on social media should be cross-validated with Nielsen and other data sources to differentiate emerging brands that have become established from those with limited sales and distribution.
- 18 January 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (1) , e30257
Open AccessIdentifying Electronic Nicotine Delivery System Brands and Flavors on Instagram: Natural Language Processing Analysis
Background: Electronic nicotine delivery system (ENDS) brands, such as JUUL, used social media as a key component of their marketing strategy, which led to massive sales growth from 2015 to 2018. During this time, ENDS use rapidly increased among youths and young adults, with flavored products being particularly popular among these groups. Objective: The aim of our study is to develop a named entity recognition (NER) model to identify potential emerging vaping brands and flavors from Instagram post text. NER is a natural language processing task for identifying specific types of words (entities) in text based on the characteristics of the entity and surrounding words. Methods: NER models were trained on a labeled data set of 2272 Instagram posts coded for ENDS brands and flavors. We compared three types of NER models—conditional random fields, a residual convolutional neural network, and a fine-tuned distilled bidirectional encoder representations from transformers (FTDB) network—to identify brands and flavors in Instagram posts with key model outcomes of precision, recall, and F1 scores. We used data from Nielsen scanner sales and Wikipedia to create benchmark dictionaries to determine whether brands from established ENDS brand and flavor lists were mentioned in the Instagram posts in our sample. To prevent overfitting, we performed 5-fold cross-validation and reported the mean and SD of the model validation metrics across the folds. Results: For brands, the residual convolutional neural network exhibited the highest mean precision (0.797, SD 0.084), and the FTDB exhibited the highest mean recall (0.869, SD 0.103). For flavors, the FTDB exhibited both the highest mean precision (0.860, SD 0.055) and recall (0.801, SD 0.091). All NER models outperformed the benchmark brand and flavor dictionary look-ups on mean precision, recall, and F1. Comparing between the benchmark brand lists, the larger Wikipedia list outperformed the Nielsen list in both precision and recall. Conclusions: Our findings suggest that NER models correctly identified ENDS brands and flavors in Instagram posts at rates competitive with, or better than, others in the published literature. Brands identified during manual annotation showed little overlap with those in Nielsen scanner data, suggesting that NER models may capture emerging brands with limited sales and distribution. NER models address the challenges of manual brand identification and can be used to support future infodemiology and infoveillance studies. Brands identified on social media should be cross-validated with Nielsen and other data sources to differentiate emerging brands that have become established from those with limited sales and distribution.
- Open Access
- 9 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Identifying Electronic Nicotine Delivery System Brands and Flavors on Instagram: Natural Language Processing Analysis (Preprint)
BACKGROUND Electronic nicotine delivery system (ENDS) brands, such as JUUL, used social media as a key component of their marketing strategy, which led to massive sales growth from 2015 to 2018. During this time, ENDS use rapidly increased among youths and young adults, with flavored products being particularly popular among these groups. OBJECTIVE The aim of our study is to develop a named entity recognition (NER) model to identify potential emerging vaping brands and flavors from Instagram post text. NER is a natural language processing task for identifying specific types of words (entities) in text based on the characteristics of the entity and surrounding words. METHODS NER models were trained on a labeled data set of 2272 Instagram posts coded for ENDS brands and flavors. We compared three types of NER models—conditional random fields, a residual convolutional neural network, and a fine-tuned distilled bidirectional encoder representations from transformers (FTDB) network—to identify brands and flavors in Instagram posts with key model outcomes of precision, recall, and F1 scores. We used data from Nielsen scanner sales and Wikipedia to create benchmark dictionaries to determine whether brands from established ENDS brand and flavor lists were mentioned in the Instagram posts in our sample. To prevent overfitting, we performed 5-fold cross-validation and reported the mean and SD of the model validation metrics across the folds. RESULTS For brands, the residual convolutional neural network exhibited the highest mean precision (0.797, SD 0.084), and the FTDB exhibited the highest mean recall (0.869, SD 0.103). For flavors, the FTDB exhibited both the highest mean precision (0.860, SD 0.055) and recall (0.801, SD 0.091). All NER models outperformed the benchmark brand and flavor dictionary look-ups on mean precision, recall, and F1. Comparing between the benchmark brand lists, the larger Wikipedia list outperformed the Nielsen list in both precision and recall. CONCLUSIONS Our findings suggest that NER models correctly identified ENDS brands and flavors in Instagram posts at rates competitive with, or better than, others in the published literature. Brands identified during manual annotation showed little overlap with those in Nielsen scanner data, suggesting that NER models may capture emerging brands with limited sales and distribution. NER models address the challenges of manual brand identification and can be used to support future infodemiology and infoveillance studies. Brands identified on social media should be cross-validated with Nielsen and other data sources to differentiate emerging brands that have become established from those with limited sales and distribution.
- 9 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessIdentifying Electronic Nicotine Delivery System Brands and Flavors on Instagram: Natural Language Processing Analysis (Preprint)
BACKGROUND Electronic nicotine delivery system (ENDS) brands, such as JUUL, used social media as a key component of their marketing strategy, which led to massive sales growth from 2015 to 2018. During this time, ENDS use rapidly increased among youths and young adults, with flavored products being particularly popular among these groups. OBJECTIVE The aim of our study is to develop a named entity recognition (NER) model to identify potential emerging vaping brands and flavors from Instagram post text. NER is a natural language processing task for identifying specific types of words (entities) in text based on the characteristics of the entity and surrounding words. METHODS NER models were trained on a labeled data set of 2272 Instagram posts coded for ENDS brands and flavors. We compared three types of NER models—conditional random fields, a residual convolutional neural network, and a fine-tuned distilled bidirectional encoder representations from transformers (FTDB) network—to identify brands and flavors in Instagram posts with key model outcomes of precision, recall, and F1 scores. We used data from Nielsen scanner sales and Wikipedia to create benchmark dictionaries to determine whether brands from established ENDS brand and flavor lists were mentioned in the Instagram posts in our sample. To prevent overfitting, we performed 5-fold cross-validation and reported the mean and SD of the model validation metrics across the folds. RESULTS For brands, the residual convolutional neural network exhibited the highest mean precision (0.797, SD 0.084), and the FTDB exhibited the highest mean recall (0.869, SD 0.103). For flavors, the FTDB exhibited both the highest mean precision (0.860, SD 0.055) and recall (0.801, SD 0.091). All NER models outperformed the benchmark brand and flavor dictionary look-ups on mean precision, recall, and F1. Comparing between the benchmark brand lists, the larger Wikipedia list outperformed the Nielsen list in both precision and recall. CONCLUSIONS Our findings suggest that NER models correctly identified ENDS brands and flavors in Instagram posts at rates competitive with, or better than, others in the published literature. Brands identified during manual annotation showed little overlap with those in Nielsen scanner data, suggesting that NER models may capture emerging brands with limited sales and distribution. NER models address the challenges of manual brand identification and can be used to support future infodemiology and infoveillance studies. Brands identified on social media should be cross-validated with Nielsen and other data sources to differentiate emerging brands that have become established from those with limited sales and distribution.