TAT. Yu. Anushchenko

T. Yu. Anushchenko

*This is an algorithmically generated author record based on publicly available information.

T. Yu. Anushchenko has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modern self-fixing surgical suture material and its application in urology

    by Z. I. Mul'Darov, N. D. Kubin, I. V. Karnaukhov, T. Yu. Anushchenko, V. P. Britov, E. S. Shpilenya, I. B. Dzhalilov, D. D. Shkharupa, N. K. Gadzhiev, З. И. Мульдаров, et al.

    Introduction. Self-fixating barbed sutures are now widely used across surgical specialties, including urology, where they have been shown to reduce operative time and potentially lower complication rates. Despite their growing adoption, there is a paucity of comparative data on the structural characteristics of different barbed suture designs. Objective. To conduct an experimental comparison of the most commonly used self-fixating suture materials by evaluating their structural features, fixation properties, and tissue interaction using both a polymeric kidney model and ex vivo ovine kidney tissue. Materials & methods. Three self-fixating sutures with different barb configurations were compared: Stratafix Spiral PDO, V Loc 180, and Alcadinone (USP 2 0). Testing was performed at Linтекs LLC and the St. Petersburg State Institute of Technology. Fixation characteristics were evaluated using an Instron tensile testing machine, and suture tracks were analysed in a polymeric kidney model and in ex vivo sheep kidney specimens. Results. Experiments conducted on a polymeric kidney model (hardness 38 ± 2.5 Shore units) and on ex vivo ovine kidney tissue evaluated the effect of barb configuration on the performance of self-fixating sutures (Alcadinone, Stratafix Spiral PDO, V Loc 180). Microscopic examination revealed that sutures with a dual-angle cut produced coarser tissue tracks and exerted a more pronounced sawing effect, thereby increasing the risk of tissue trauma; however, these sutures also demonstrated significantly higher fixation strength compared with single-angle barbed designs. Based on these findings, medical and technical specifications for an optimal self-fixating suture for urological applications were established, and potential indications across various urological procedures were proposed. Conclusion. This experimental study has defined the key medical and technical requirements for an ideal self-fixating suture in urology: biocompatibility and tissue inertness, optimal fixation strength with minimal tissue trauma, availability in both unidirectional and bidirectional barb configurations, in both absorbable and non-absorbable polymers, and inclusion of a terminal loop to facilitate placement of the first stitch. These findings provide a foundation for the development of Russian produced suture materials tailored to the specific needs of urological practice.

  • Open Access

    Hernia mesh: the evolution of materials and a look into the future (literature review)

    by A. M. Belousov, T. S. Filippenko, T. Yu. Anushchenko

    Mesh implants have become an integral part of modern hernia surgery. Although polypropylene remains the most used material, its limitations – such as degradation, chronic inflammation, and potential systemic immune reactions – have drawn increasing attention. As a result, alternative polymers such as polyvinylidene fluoride (PVDF) are being actively explored for their superior biocompatibility, chemical stability, and lower complication rates. This review outlines the historical evolution and current classifications of synthetic meshes used in abdominal wall reconstruction. It highlights the biomechanical, morphological, and immunological characteristics of various implant materials, with particular emphasis on PVDF-based prostheses. Future directions are also discussed, including the development of bioactive, MRI-visible, and patient-specific meshes.


  • Results of the use of adhesion barriers Adept and Mesogel in intraperitoneal onlay mesh (IPOM) in the experiment

    by V.P. Armashov, A.M. Belousov, P.A. Potapov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, K.O. Timofeeva, N.L. Matveev

    OBJECTIVE Evaluation of the results of the use of adhesion barrier agents Adept and Mesogel in intraperitoneal onlay mesh repair in the experiment. MATERIAL AND METHODS In 4 pigs during laparoscopy, 24 meshes with fluoropolymer coating Ftorex and with collagen coating Symbotex were fixed on the parietal peritoneum. The meshes were fixed with a SecureStrap hernia stapler or fluoropolymer-coated thread Ftorex. In 2 animals adhesion barriers Adept (4% icodextrin solution) and Mesogel (gel based on carboxymethyl cellulose) were injected into the abdominal cavity. After 45 days, the animals were taken out of the experiment. The number of meshes with inflammation, deformation, retraction, migration of tacks and sutures, mesh area, mechanical strength of mesh fixation, adhesion formation, thickness, breaking load and breaking elongation of the mesh-tissue complex were recorded, histological changes. RESULTS The use of adhesion barriers did not cause a difference in the number of meshes with signs of inflammation, deformation, retraction, mechanical strength of fixation. Tack migration or suture unraveling was not observed. Adhesive barriers reduced mesh retraction. After excision, the area of the mesh in the group without an adhesion barrier was 82.1% of the initial one, with an adhesion barrier — 92.0% (p=0.018). The Ftorex mesh was more susceptible to this process. Adhesion barriers had the advantage of reducing adhesion, but no significant difference was found. The indicators turned out to be somewhat better when using Mesogel. In animals that were injected with adhesion barriers, adhesions to parenchymal and hollow organs were absent. Mesogel did not affect the biomechanical strength of the mesh-tissue complex. Adept resulted in the formation of a thinner mesh-tissue complex (0.6±0.1 mm vs. 0.9±0.0 mm in the Mesogel group, p=0.005) and reduced mean elongation at break (77.4±4.3 mm vs. 91.7±0.7 mm in the Mesogel group, p=0.029). Histological examination showed that when using adhesion barriers over the surface of the peritoneum, the number of connective tissue cords covered with neoperitoneum increases (p=0.024). It cannot be excluded that it is the number of these structures that determines the anti-adhesive properties of the barrier. CONCLUSION In case of intraperitoneal onlay mesh repair, the use of Adept and Mesogel adhesion barriers does not cause clinically significant adverse reactions and complications. The agents have approximately comparable capabilities in the additional prevention of adhesions, however, Adept changes the biomechanical strength of the mesh-tissue complex, which requires further research.


  • Histological changes in intraperitoneal onlay mesh (IPOM) with synthetic and biological meshes. Results of the chronic experiment

    by A.M. Belousov, V.P. Armashov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, N.M. Blum, P.A. Potapov, K.O. Timofeeva, A.A. Putulyan, N.L. Matveev

    Objective. The objective of the study was to analyze histological changes in the site of the meshes FTOREX, FTOREX coated with carboxymethylcellulose, Ventralight ST, Symbotex, REPEREN-16-2 and decellularized porcine peritoneum on the parietal peritoneum of the pig. Material and methods. At laparoscopy, 6 different meshes were placed intraperitoneally in each of the 3 pigs. After 90 days, the animals were taken out of the experiment. After staining with hematoxylin and eosin, quantitative morphometry and counting the number of vessels and cells in the interstitium in the areas of the mesh and peritoneum were performed. An immunohistochemical study with an antibody to pancytokeratins assessed the state of the initial peritoneum and neoperitoneum. Results. According to morphological characteristics, the meshes were divided into 3 groups: 1) with fluoropolymer coating FTOREX, 2) Ventralight ST and Symbotex, 3) REPEREN and decellularized peritoneum. In group 1, the surface area of the mesh threads was optimal in terms of the arrangement and arrangement of the threads relative to each other. This contributed to the formation of a relatively dense fibrous framework and a place to preserve the underlying peritoneum involved in the formation of the neoperitoneum. Despite the smallest surface area of the threads, in group 3, the greatest fibroblastic reaction was noted. Inflammatory changes were the least pronounced in group 1. They were the greatest in group 3, where there was a pronounced leukocyte reaction, combined with the processes of metaplasia, the development of fibrinoid necrosis, and the progression of the secondary inflammatory process. In group 1, the optimal ratio of newly formed vessels was noted, in group 2 — veins prevailed over arteries, in group 3 — the number of vessels was minimal. Immunohistochemical study showed that in group 1, mesothelial cells covered almost the entire surface of the implant, and there were also areas of preserved basic peritoneum. In group 2, mesothelium also covered most of the surface of the meshes, but the underlying peritoneum was absent. In group 3, on the contrary, a significant number of extended areas not covered with mesothelium were revealed. Conclusion. The conducted morphological and morphometric study showed that the most balanced ratio of the components of the newly formed fibrous tissue and blood vessels is observed when using implants with a fluoropolymer coating FTOREX. At the same time, the remaining basic peritoneum actively participated in the formation of the neoperitoneum. The Ventralight ST and Symbotex meshes also contributed to the formation of a full-fledged fibrous tissue and adequate vascular proliferation, however, they prevented the preservation of the underlying peritoneum, which practically excluded its participation in the formation of the neoperitoneum. The REPEREN mesh and decellularized porcine peritoneum led to the least balanced cell and vascular proliferation and the greatest fibroplastic reaction, which could further negatively affect the state of the formed scar.


  • Safety of mesh with fluoropolymer coating during intra-abdominal placement in large animals: results of the pilot study

    by A.M. Belousov, V.P. Armashov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, V.A. Zhukovskiy, N.L. Matveev

    Objective. When performing laparoscopic intraperitoneal hernioplasty (IPOM), endoprostheses made of fluoropolymers are often used. However, there is no data in the literature on the intra-abdominal use of inexpensive polyester prostheses with a fluoropolymer coating compared to composite implants. Thus, the aim of the pilot study was a preliminary assessment of the safety profile of FTOREX mesh endoprostheses during intra-abdominal placement in large animals. Material and methods. 6 endoprostheses were installed laparoscopically intraperitoneally in each of the 3 pigs: 1) FTOREX; 2) FTOREX with a layer of carboxymethylcellulose; 3) REPEREN-16-2; 4) SYMBOTEX; 5) VENTRALIGHT ST; 6) decellularized pork peritoneum. Fixation was performed with a herniator, transfascial sutures were not used. Relaparoscopy was performed after 45 days, and withdrawal from the experiment was performed after 90 days. Performance characteristics, signs of deformation and retraction, parameters of spike formation were evaluated. Results. All the animals survived, no complications were observed. There were no clinical manifestations or behavioral reactions indicating the presence of adhesions. The most convenient to use were the SYMBOTEX and FTOREX implants (5.0 points each). By the end of the experiment, deformation and retraction were noted in both variants of the FTOREX implants and the REPEREN prosthesis. These changes were completely absent only when using the SYMBOTEX endoprosthesis. According to the number of implants with adhesions, by the end of the observation, both variants of FTOREX prostheses occupied an intermediate position between the Reference (the worst indicator) and VENTRALIGHT ST (the best indicator). However, both FTOREX endoprostheses showed the best performance among all implants in the integral assessment of adhesions, as well as in terms of parameters such as the area and appearance of adhesions, and in terms of the strength of the joints, they were second only to the VENTRALIGHT ST endoprosthesis (0.67 vs. 0.5 points). During the study, there was no reliable dependence of deformation, retraction and adhesion formation indicators on the type of implant. Conclusion. The results of the pilot study showed that all the implants used did not cause any clinically significant adverse reactions or complications. FTOREX endoprostheses with their intraperitoneal installation have anti-adhesive properties that are not inferior to VENTRALIGHT ST or SYMBOTEX composite implants. However, having less rigidity, they are more often deformed and subjected to retraction.


  • Open Access

    Anti-adhesive membranes based on crosslinked carboxymethyl cellulose

    by V. A. Zhukovskiy, V. E. Nemilov, T. S. Filipenko, T. Y. Anuschenko

    In recent times, new anti-adhesion devices including devices based on carboxymethyl cellulose (CMC), which have “barrier” effect are being developed and actively introduced into surgical practice. The “barrier” should be completely resorbed after the time required to healing the morphofunctional integrity of the injured peritoneum, be economically available and easy to use (including laparoscopic technologies). But the time when the CMC is in the body is insufficient to prevent the formation of adhesions, particularly in the presence of non-absorbable rigid implants. The reactive functional groups in CMC allow to transform the CMC-macromolecule into a spatial structure. For this are required the using of bifunctional (bicarboxylic or aminocarboxylic) acids and the transform of a part of the carboxyl groups from the Na-form to the hardly soluble H-form, i.e., it is necessary to crosslink CMC-macromolecules. Adipic acid and glutaric acid, aminoacetic acid and amino capronic acid used are linking agents. The influence of modification parameters on the degree of polymers swelling in water is studied. As a result, to obtain membranes designed for the treatment of adhesive disease, it is recommended to use additives in CMC of bifunctional compounds.