TFT. S. Filippenko

T. S. Filippenko

*This is an algorithmically generated author record based on publicly available information.

T. S. Filippenko has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hernia mesh: the evolution of materials and a look into the future (literature review)

    by A. M. Belousov, T. S. Filippenko, T. Yu. Anushchenko

    Mesh implants have become an integral part of modern hernia surgery. Although polypropylene remains the most used material, its limitations – such as degradation, chronic inflammation, and potential systemic immune reactions – have drawn increasing attention. As a result, alternative polymers such as polyvinylidene fluoride (PVDF) are being actively explored for their superior biocompatibility, chemical stability, and lower complication rates. This review outlines the historical evolution and current classifications of synthetic meshes used in abdominal wall reconstruction. It highlights the biomechanical, morphological, and immunological characteristics of various implant materials, with particular emphasis on PVDF-based prostheses. Future directions are also discussed, including the development of bioactive, MRI-visible, and patient-specific meshes.


  • Open Access

    Comparison of pathomorphologic properties of non-resorbable and partially resorbable implants for reconstructive surgery of pelvic organ prolapse and stress urinary incontinence: an animal model study

    by D. D. Shkarupa, R. A. Shakhaliev, A. S. Shulgin, T. S. Filipenko, N. D. Kubin, I. A. Labetov

    Introduction. It is well-known that the use of transvaginal mesh implants is not devoid of specific complications that meaningfully impair the quality of life of female patients. The volume of permanent material used has been shown to correlate closely with the risk of implant-associated complications. Thus, there is a need to develop a new generation of implants that retain the advantages of a permanent mesh implant but with minimal risk of implant-associated complications. Meanwhile, there are insufficient data on the organism's response to this type of synthetic implant.Objective. To compare the histological changes in the soft tissues of the rabbit anterior abdominal wall in the implantation zone of the new generation partially resorbable implant and non-absorbable polypropylene mesh implant on the animal model.Materials & methods. We have previously developed a partially resorbable ligature delivery system for axial fixation of pelvic floor structures, performed technical analysis, and compared biomechanical and pathomorphological properties after implantation in an animal model experiment. The present study was conducted on 39 male rabbits of Chinchilla breed, randomised into three groups according to the type of implanted material: a partially resorbable ligature delivery system Axilen and Axilen Rapid [Lintex, LLC], and a non-resorbable polypropylene mesh implant Urosling. After the rabbits were removed from the experiment, the obtained biomaterial was subjected to histological study.Results. In the group with partially resorbable implants Axilen and Axilen Rapid, less inflammation and better tissue integration were observed compared to the polypropylene implant Urosling. This indicates a potential reduction in the risk of postoperative complications and an improvement in the quality of life for patients.Conclusion. The results of the experimental study confirm the advantages of using partially resorbable implants over traditional polypropylene meshes in pelvic floor reconstructive surgery. However, further research is needed to confirm the long-term safety and effectiveness of the new generation of implants.

  • Results of the use of adhesion barriers Adept and Mesogel in intraperitoneal onlay mesh (IPOM) in the experiment

    by V.P. Armashov, A.M. Belousov, P.A. Potapov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, K.O. Timofeeva, N.L. Matveev

    OBJECTIVE Evaluation of the results of the use of adhesion barrier agents Adept and Mesogel in intraperitoneal onlay mesh repair in the experiment. MATERIAL AND METHODS In 4 pigs during laparoscopy, 24 meshes with fluoropolymer coating Ftorex and with collagen coating Symbotex were fixed on the parietal peritoneum. The meshes were fixed with a SecureStrap hernia stapler or fluoropolymer-coated thread Ftorex. In 2 animals adhesion barriers Adept (4% icodextrin solution) and Mesogel (gel based on carboxymethyl cellulose) were injected into the abdominal cavity. After 45 days, the animals were taken out of the experiment. The number of meshes with inflammation, deformation, retraction, migration of tacks and sutures, mesh area, mechanical strength of mesh fixation, adhesion formation, thickness, breaking load and breaking elongation of the mesh-tissue complex were recorded, histological changes. RESULTS The use of adhesion barriers did not cause a difference in the number of meshes with signs of inflammation, deformation, retraction, mechanical strength of fixation. Tack migration or suture unraveling was not observed. Adhesive barriers reduced mesh retraction. After excision, the area of the mesh in the group without an adhesion barrier was 82.1% of the initial one, with an adhesion barrier — 92.0% (p=0.018). The Ftorex mesh was more susceptible to this process. Adhesion barriers had the advantage of reducing adhesion, but no significant difference was found. The indicators turned out to be somewhat better when using Mesogel. In animals that were injected with adhesion barriers, adhesions to parenchymal and hollow organs were absent. Mesogel did not affect the biomechanical strength of the mesh-tissue complex. Adept resulted in the formation of a thinner mesh-tissue complex (0.6±0.1 mm vs. 0.9±0.0 mm in the Mesogel group, p=0.005) and reduced mean elongation at break (77.4±4.3 mm vs. 91.7±0.7 mm in the Mesogel group, p=0.029). Histological examination showed that when using adhesion barriers over the surface of the peritoneum, the number of connective tissue cords covered with neoperitoneum increases (p=0.024). It cannot be excluded that it is the number of these structures that determines the anti-adhesive properties of the barrier. CONCLUSION In case of intraperitoneal onlay mesh repair, the use of Adept and Mesogel adhesion barriers does not cause clinically significant adverse reactions and complications. The agents have approximately comparable capabilities in the additional prevention of adhesions, however, Adept changes the biomechanical strength of the mesh-tissue complex, which requires further research.


  • Histological changes in intraperitoneal onlay mesh (IPOM) with synthetic and biological meshes. Results of the chronic experiment

    by A.M. Belousov, V.P. Armashov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, N.M. Blum, P.A. Potapov, K.O. Timofeeva, A.A. Putulyan, N.L. Matveev

    Objective. The objective of the study was to analyze histological changes in the site of the meshes FTOREX, FTOREX coated with carboxymethylcellulose, Ventralight ST, Symbotex, REPEREN-16-2 and decellularized porcine peritoneum on the parietal peritoneum of the pig. Material and methods. At laparoscopy, 6 different meshes were placed intraperitoneally in each of the 3 pigs. After 90 days, the animals were taken out of the experiment. After staining with hematoxylin and eosin, quantitative morphometry and counting the number of vessels and cells in the interstitium in the areas of the mesh and peritoneum were performed. An immunohistochemical study with an antibody to pancytokeratins assessed the state of the initial peritoneum and neoperitoneum. Results. According to morphological characteristics, the meshes were divided into 3 groups: 1) with fluoropolymer coating FTOREX, 2) Ventralight ST and Symbotex, 3) REPEREN and decellularized peritoneum. In group 1, the surface area of the mesh threads was optimal in terms of the arrangement and arrangement of the threads relative to each other. This contributed to the formation of a relatively dense fibrous framework and a place to preserve the underlying peritoneum involved in the formation of the neoperitoneum. Despite the smallest surface area of the threads, in group 3, the greatest fibroblastic reaction was noted. Inflammatory changes were the least pronounced in group 1. They were the greatest in group 3, where there was a pronounced leukocyte reaction, combined with the processes of metaplasia, the development of fibrinoid necrosis, and the progression of the secondary inflammatory process. In group 1, the optimal ratio of newly formed vessels was noted, in group 2 — veins prevailed over arteries, in group 3 — the number of vessels was minimal. Immunohistochemical study showed that in group 1, mesothelial cells covered almost the entire surface of the implant, and there were also areas of preserved basic peritoneum. In group 2, mesothelium also covered most of the surface of the meshes, but the underlying peritoneum was absent. In group 3, on the contrary, a significant number of extended areas not covered with mesothelium were revealed. Conclusion. The conducted morphological and morphometric study showed that the most balanced ratio of the components of the newly formed fibrous tissue and blood vessels is observed when using implants with a fluoropolymer coating FTOREX. At the same time, the remaining basic peritoneum actively participated in the formation of the neoperitoneum. The Ventralight ST and Symbotex meshes also contributed to the formation of a full-fledged fibrous tissue and adequate vascular proliferation, however, they prevented the preservation of the underlying peritoneum, which practically excluded its participation in the formation of the neoperitoneum. The REPEREN mesh and decellularized porcine peritoneum led to the least balanced cell and vascular proliferation and the greatest fibroplastic reaction, which could further negatively affect the state of the formed scar.


  • Open Access

    Сomparison of biomechanical properties of non-absorbable and partially absorbable mesh implants used in surgery for urinary incontinence and genital prolapse: experimental study

    by D. D. Shkarupa, R. A. Shakhaliev, A. S. Shulgin, T. S. Filipenko, N. D. Kubin, I. A. Labetov, D. A. Suchkov

    Introduction. The amount of non-absorbable synthetic material used in the surgical treatment of pelvic organ prolapse and stress urinary incontinence has been shown to directly correlate with the risks of mesh-associated complications. Previously, we developed a partially absorbable implant. Currently, there are insufficient data on the use of partially absorbable implants in female pelvic floor reconstruction, which requires comparative biomechanical and pathomorphological studies.Objective. To compare the biomechanical properties of a new generation partially absorbable implants and nonabsorbable polypropylene mesh implants during animal model.Materials & methods. Thirty-nine rabbits weighing 3200 ± 250 g were randomised into three groups depending on the implanted endoprosthesis: group 1 (n = 15) — “Axilen” implant (polydioxanone 98%, polypropylene 2%), group 2 (n = 15) — “Axilen Rapid” implant (polyglycapron 98%, polypropylene 2%), group 3 (n = 9) — “Urosling 1” implant. After implantation, rabbits of all 3 groups were divided into 3 subgroups according to the withdrawal period from the experiment: 14 days, 60 days, and 180 days. The biomaterial obtained was subjected to two studies: evaluation of the macroscopic view of the explanted mesh endoprosthesis with the formed capsule and the surrounding tissues, study of the biomechanical properties of the formed connective tissue capsule with the implant.Results. According to macroscopic evaluation, there was a less significant tissue reaction to partially absorbed implants. A comparative analysis of biomechanical indices revealed no statistically significant difference in rupture elongation at all follow-up periods among the presented groups. Tensile strength, at 60 and 180 days, was not statistically different between the groups described. At 14 days, there was a statistically significant difference in tensile strength between groups 1 and 3 (p = 0.003).Conclusion. During biomechanical animal experiments, the connective tissue capsule formed on the partially absorbable implant was not inferior to the similar parameter of the non-absorbable sample in its tensile strength, which explains a great potential for the use of partially absorbable implants in reconstructive surgery of pelvic organ prolapse and stress urinary incontinence.


  • Safety of mesh with fluoropolymer coating during intra-abdominal placement in large animals: results of the pilot study

    by A.M. Belousov, V.P. Armashov, D.D. Shkarupa, T.YU. Anushchenko, T.S. Filipenko, V.A. Zhukovskiy, N.L. Matveev

    Objective. When performing laparoscopic intraperitoneal hernioplasty (IPOM), endoprostheses made of fluoropolymers are often used. However, there is no data in the literature on the intra-abdominal use of inexpensive polyester prostheses with a fluoropolymer coating compared to composite implants. Thus, the aim of the pilot study was a preliminary assessment of the safety profile of FTOREX mesh endoprostheses during intra-abdominal placement in large animals. Material and methods. 6 endoprostheses were installed laparoscopically intraperitoneally in each of the 3 pigs: 1) FTOREX; 2) FTOREX with a layer of carboxymethylcellulose; 3) REPEREN-16-2; 4) SYMBOTEX; 5) VENTRALIGHT ST; 6) decellularized pork peritoneum. Fixation was performed with a herniator, transfascial sutures were not used. Relaparoscopy was performed after 45 days, and withdrawal from the experiment was performed after 90 days. Performance characteristics, signs of deformation and retraction, parameters of spike formation were evaluated. Results. All the animals survived, no complications were observed. There were no clinical manifestations or behavioral reactions indicating the presence of adhesions. The most convenient to use were the SYMBOTEX and FTOREX implants (5.0 points each). By the end of the experiment, deformation and retraction were noted in both variants of the FTOREX implants and the REPEREN prosthesis. These changes were completely absent only when using the SYMBOTEX endoprosthesis. According to the number of implants with adhesions, by the end of the observation, both variants of FTOREX prostheses occupied an intermediate position between the Reference (the worst indicator) and VENTRALIGHT ST (the best indicator). However, both FTOREX endoprostheses showed the best performance among all implants in the integral assessment of adhesions, as well as in terms of parameters such as the area and appearance of adhesions, and in terms of the strength of the joints, they were second only to the VENTRALIGHT ST endoprosthesis (0.67 vs. 0.5 points). During the study, there was no reliable dependence of deformation, retraction and adhesion formation indicators on the type of implant. Conclusion. The results of the pilot study showed that all the implants used did not cause any clinically significant adverse reactions or complications. FTOREX endoprostheses with their intraperitoneal installation have anti-adhesive properties that are not inferior to VENTRALIGHT ST or SYMBOTEX composite implants. However, having less rigidity, they are more often deformed and subjected to retraction.


  • Open Access

    New-generation synthetic implants for the surgical correction of pelvic organ prolapse and stress urinary incontinence: design and testing

    by D. D. Shkarupa, R. A. Shakhaliev, A. S. Shulgin, T. S. Filipenko, N. D. Kubin, D. A. Suchkov, O. A. Shkarupa

    Introduction. Up to 50.0% of postpartum women experience stress urinary incontinence (SUI) and pelvic organ prolapse (POP). One of the most common and pathogenetically substantiated methods for surgical correction of severe SIU and POP is prosthetic reconstruction of the pelvic floor, involves the use of monofilament polypropylene surgical meshes through vaginal or laparoscopic access.. However, this way is associated with specific problems, i.e., primarily mucosal erosions, and pelvic pain. This has served as a trigger for the development of new materials that reduce the likelihood of such side effects.Objective. To develop the new-generation synthetic implants for surgical correction of stress urinary incontinence and pelvic organ prolapse.Materials and methods. The main development stages: 1. design of an experimental sample of a synthetic implant (evaluation of basic, physical and mechanical properties). 2. test of an experimental sample obtained in vitro.Results. A bioresorbable polypropylene ligature delivery system was developed and manufactured in two variants: for the POP correction (mesh tape with a width of 13 – 15 mm) and for the SUI correction (mesh tape with a width of 10 – 11 mm).Conclusion. Based on the results of the in vitro tests, we can conclude that the synthetic implants developed are able to provide physiological longitudinal (axial) support of the necessary pelvic floor sections and reduce the risk of postoperative complications. Further in vivo studies are required to assess the response of living tissue to the implantation of this type of synthetic implants.


  • Open Access

    Imparting ion-exchange properties to fibrous polycaproamide materials by chemically initiated graft copolymerization

    by V. A. Zhukovskiy, V. A. Khokhlova, T. S. Filipenko, T. U. Anuschenko

    The study of the types and properties of surgical threads, as well as the experience in the production of suture surgical material and its use shows that the most promising for surgical practice are threads with antimicrobial properties. Of the methods for fixing medicinal compounds with chemical bonds for suture materials, the most expedient is their attachment by the reaction of ion-exchange interaction. Since polycaproamide (PCA) practically does not contain functional groups, a preliminary modification stage is required to impart ion-exchange properties to PCA fibrous materials. One of these stages of modification is the process of graft polymerization of methacrylic acid (MAA) in order to create active groups on the fiber, for example, peroxide or hydroperoxide. Modification of chemical fibers by graft copolymerization with inogenic monomers is one of the widespread methods of obtaining fibrous ion exchangers. Principles, new approaches and technologies for imparting ion-exchange properties to fibrous polycaproamide materials by chemically initiated graft copolymerization have been developed. Regularities in the production of fibrous PCA of sorption active materials by chemical initiation by a redox system (Fe2++H2O2) located in a modifying bath, as well as by pre-oxidation of fiber PCA in order to create peroxide and hydroperoxide groups on the fiber, are revealed.

  • Open Access

    Anti-adhesive membranes based on crosslinked carboxymethyl cellulose

    by V. A. Zhukovskiy, V. E. Nemilov, T. S. Filipenko, T. Y. Anuschenko

    In recent times, new anti-adhesion devices including devices based on carboxymethyl cellulose (CMC), which have “barrier” effect are being developed and actively introduced into surgical practice. The “barrier” should be completely resorbed after the time required to healing the morphofunctional integrity of the injured peritoneum, be economically available and easy to use (including laparoscopic technologies). But the time when the CMC is in the body is insufficient to prevent the formation of adhesions, particularly in the presence of non-absorbable rigid implants. The reactive functional groups in CMC allow to transform the CMC-macromolecule into a spatial structure. For this are required the using of bifunctional (bicarboxylic or aminocarboxylic) acids and the transform of a part of the carboxyl groups from the Na-form to the hardly soluble H-form, i.e., it is necessary to crosslink CMC-macromolecules. Adipic acid and glutaric acid, aminoacetic acid and amino capronic acid used are linking agents. The influence of modification parameters on the degree of polymers swelling in water is studied. As a result, to obtain membranes designed for the treatment of adhesive disease, it is recommended to use additives in CMC of bifunctional compounds.