Changsheng Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Changsheng Hu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Dehong Xu
Zhejiang University
9 shared publications - Min Chen
College of Electrical Engineering, Institute of Power Electronics, Zhejiang University, Hangzhou, China
5 shared publications Xiaoyu Jia
Institute of Power Electronics, Zhejiang University, Hangzhou, China
3 shared publications- Keyan Shi
College of Electrical Engineering, Institute of Power Electronics, Zhejiang University, Hangzhou, China
2 shared publications - Min Chen
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Ping Lin
School of Control Science and Engineering, Dalian University of Technology, Dalian 116024, China
2 shared publications
Latest Publications
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9811-9823
An Optimized Fault-Tolerant Control Strategy Based on Dynamic Modulation Voltage Adjustment for Solid-State Transformers
Solid-state transformers (SSTs) have broad application prospects in medium-voltage dc distribution systems. However, the large number of switching devices in SSTs makes it prone to failure. The cascaded structure of SSTs facilitates redundant fault-tolerant control in the event of a failure. Nevertheless, traditional redundancy-based fault-tolerant control methods will lead to current surges when bypassing or inserting a module. In this article, an optimized fault-tolerant control strategy based on modulation voltage correction is proposed. To reduce the voltage and current fluctuations caused by the removal of the faulty module, the new modulation voltage signal is calculated by the bus voltage of the normal operating modules, the bus voltage of the redundant module and the original modulation voltage signal. The principle of dynamic adjustment of modulation voltage is analyzed. Furthermore, during the fault-tolerant shifting process, the control mode is changed to achieve smooth fault-tolerant shifting while ensuring control continuity. The effectiveness of the proposed fault-tolerant control strategy is verified through simulation and experiments.
- 18 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9811-9823
An Optimized Fault-Tolerant Control Strategy Based on Dynamic Modulation Voltage Adjustment for Solid-State Transformers
Solid-state transformers (SSTs) have broad application prospects in medium-voltage dc distribution systems. However, the large number of switching devices in SSTs makes it prone to failure. The cascaded structure of SSTs facilitates redundant fault-tolerant control in the event of a failure. Nevertheless, traditional redundancy-based fault-tolerant control methods will lead to current surges when bypassing or inserting a module. In this article, an optimized fault-tolerant control strategy based on modulation voltage correction is proposed. To reduce the voltage and current fluctuations caused by the removal of the faulty module, the new modulation voltage signal is calculated by the bus voltage of the normal operating modules, the bus voltage of the redundant module and the original modulation voltage signal. The principle of dynamic adjustment of modulation voltage is analyzed. Furthermore, during the fault-tolerant shifting process, the control mode is changed to achieve smooth fault-tolerant shifting while ensuring control continuity. The effectiveness of the proposed fault-tolerant control strategy is verified through simulation and experiments.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1254-1258
A Hybrid Control Method for High Power LLC Converter with Wide Output Voltage Range
The power supply source for electroplating, hydrogen production etc. have the characteristics of wide output voltage range, very large output current. The LLC topology is applied widely for its efficiency advantage. The paper introduced a full-bridge LLC resonant converter with input-series output-parallel structure to satisfy the circumstances of large output current. A hybrid control method is applied in the full-bridge LLC resonant converter to meet the widely output voltage range, which include the frequency modulation (FM) in high output voltage range and Phase-shifting (PS) modulation in low output voltage range. The full-bridge LLC resonant converter is designed and set up to verify the control methods.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1254-1258
A Hybrid Control Method for High Power LLC Converter with Wide Output Voltage Range
The power supply source for electroplating, hydrogen production etc. have the characteristics of wide output voltage range, very large output current. The LLC topology is applied widely for its efficiency advantage. The paper introduced a full-bridge LLC resonant converter with input-series output-parallel structure to satisfy the circumstances of large output current. A hybrid control method is applied in the full-bridge LLC resonant converter to meet the widely output voltage range, which include the frequency modulation (FM) in high output voltage range and Phase-shifting (PS) modulation in low output voltage range. The full-bridge LLC resonant converter is designed and set up to verify the control methods.
- 4 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 14942-14955
Efficiency Enhancement of DC Solid-State Transformers by Dynamically Adjusting Active Cells
A dc solid-state transformer (DCSST) is a key building block for future medium-voltage dc systems, and its efficiency is important to the entire system. High-voltage semiconductor devices enable substantial reduction of the power conversion cell count in a DCSST. The number of active (in-use) cells will influence the DCSST efficiency. In this article, the number of active cells is dynamically adjusted based on the load condition to enhance DCSST efficiency. A mapping between the number of active cells and DCSST efficiency is developed. A smooth shifting control strategy is proposed to avoid large perturbations and ensure safe operation when dynamically bypassing or inserting certain cells. An average model of a DCSST is derived to facilitate control design. Simulations and experiments are provided to verify the proposed solution.
- 4 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 14942-14955
Efficiency Enhancement of DC Solid-State Transformers by Dynamically Adjusting Active Cells
A dc solid-state transformer (DCSST) is a key building block for future medium-voltage dc systems, and its efficiency is important to the entire system. High-voltage semiconductor devices enable substantial reduction of the power conversion cell count in a DCSST. The number of active (in-use) cells will influence the DCSST efficiency. In this article, the number of active cells is dynamically adjusted based on the load condition to enhance DCSST efficiency. A mapping between the number of active cells and DCSST efficiency is developed. A smooth shifting control strategy is proposed to avoid large perturbations and ensure safe operation when dynamically bypassing or inserting certain cells. An average model of a DCSST is derived to facilitate control design. Simulations and experiments are provided to verify the proposed solution.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 7993-7999
Study of Charging Current Ripple Suppression for Battery Energy Storage Converter Under Distorted Grid Voltages
This letter proposes a charging current ripple suppression strategy for battery energy storage T-type three-level converter. Under distorted grid voltage scenarios, the harmonic contents of grid voltage lead to current ripple during battery charging. Theoretical analysis and mathematical derivations of the charging current ripple are presented. Based on the analysis, a control scheme for suppressing the charging current ripple is proposed by simplified calculating to obtain the amplitude and phase of harmonic reference current, and adding a charging current suppression loop. The suppression performance is verified via a 100-kW three-phase three-wire T-type three-level converter with battery. The experimental results prove that the charging current ripple can be effectively eliminated with the proposed strategy.
- 29 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (7) , 7993-7999
Study of Charging Current Ripple Suppression for Battery Energy Storage Converter Under Distorted Grid Voltages
This letter proposes a charging current ripple suppression strategy for battery energy storage T-type three-level converter. Under distorted grid voltage scenarios, the harmonic contents of grid voltage lead to current ripple during battery charging. Theoretical analysis and mathematical derivations of the charging current ripple are presented. Based on the analysis, a control scheme for suppressing the charging current ripple is proposed by simplified calculating to obtain the amplitude and phase of harmonic reference current, and adding a charging current suppression loop. The suppression performance is verified via a 100-kW three-phase three-wire T-type three-level converter with battery. The experimental results prove that the charging current ripple can be effectively eliminated with the proposed strategy.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10530-10534
Metal Object Detection With Detection Coils Perpendicular to Power Coils for Wireless Power Transfer Systems
In this letter, a metal object detection (MOD) method with detection coils perpendicular to power coils is proposed. Without a metal object, the induced voltage in the detection coils is ideally zero. When a metal object falls on the top of the Tx pad, an eddy current is induced, and this eddy current in the metal object will induce a voltage in the detection coils. The proposed method can perform well with misalignments between the Tx and Rx pads. No adjustments are required for different winding positions. The concept is well verified with experimental results.
- 14 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10530-10534
Metal Object Detection With Detection Coils Perpendicular to Power Coils for Wireless Power Transfer Systems
In this letter, a metal object detection (MOD) method with detection coils perpendicular to power coils is proposed. Without a metal object, the induced voltage in the detection coils is ideally zero. When a metal object falls on the top of the Tx pad, an eddy current is induced, and this eddy current in the metal object will induce a voltage in the detection coils. The proposed method can perform well with misalignments between the Tx and Rx pads. No adjustments are required for different winding positions. The concept is well verified with experimental results.
- Open Access
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 17576-17583
Power Factor Correction Modulated Wireless Power Transfer System With Series-Series Compensation
Power factor correction (PFC) is usually realized with a boost converter in a traditional power converter. This paper introduces a PFC modulated WPT method which can realize PFC function through phase-shift modulation of the primary-side inverter of a series-series (SS) WPT system. A close-loop control method of the phase-shift modulated system is also proposed for practical implementations. Without using a PFC converter, the structure of a WPT system can be simplified. Theoretical analysis and experimental results are provided to verify the idea.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 17576-17583
Open AccessPower Factor Correction Modulated Wireless Power Transfer System With Series-Series Compensation
Power factor correction (PFC) is usually realized with a boost converter in a traditional power converter. This paper introduces a PFC modulated WPT method which can realize PFC function through phase-shift modulation of the primary-side inverter of a series-series (SS) WPT system. A close-loop control method of the phase-shift modulated system is also proposed for practical implementations. Without using a PFC converter, the structure of a WPT system can be simplified. Theoretical analysis and experimental results are provided to verify the idea.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 2865-2878
Adaptive Soft-Switching Control of Active-Clamping Three-Phase Inverters
Energy stored in the resonant inductor is critical to the zero-voltage switching (ZVS) of power semiconductor devices in soft-switching active-clamping three-phase inverters. Traditionally, the soft-switching PWM timing parameters are designed based on calibrated data table. However, for motor drives or general-purpose AC power supplies, their fundamental output amplitude and frequency may vary, which makes control of the soft-switching inverter complex. It would be time-consuming and tiring to manually calibrate soft-switching timing control parameters under various operation conditions. In this paper, an adaptive soft-switching control of active-clamping three-phase inverters is proposed. The resonant inductor energy storage is adjusted to the optimal value automatically. Principles and implementation of the control are introduced. Parameters design of the adaptive control is discussed. Finally, the proposed method is verified by experiments.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 2865-2878
Adaptive Soft-Switching Control of Active-Clamping Three-Phase Inverters
Energy stored in the resonant inductor is critical to the zero-voltage switching (ZVS) of power semiconductor devices in soft-switching active-clamping three-phase inverters. Traditionally, the soft-switching PWM timing parameters are designed based on calibrated data table. However, for motor drives or general-purpose AC power supplies, their fundamental output amplitude and frequency may vary, which makes control of the soft-switching inverter complex. It would be time-consuming and tiring to manually calibrate soft-switching timing control parameters under various operation conditions. In this paper, an adaptive soft-switching control of active-clamping three-phase inverters is proposed. The resonant inductor energy storage is adjusted to the optimal value automatically. Principles and implementation of the control are introduced. Parameters design of the adaptive control is discussed. Finally, the proposed method is verified by experiments.
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (3) , 3951-3964
A ZVS-PWM Scheme for Three-Phase Active-Clamping T-Type Inverters
For increasing power density and other performance of T-type three-level inverters, the soft-switching technique is studied. This article proposes a novel zero-voltage switching (ZVS) PWM scheme for active clamping three-phase T-type inverters, which can realize the ZVS operation of all switches and reduce the switching loss. The proposed ZVS PWM scheme is evolved from discontinuous PWM and modified for the requirements of T-type inverter. It enables all switches, including main switches and auxiliary switches, operate at a fixed frequency. However, a larger current on the power semiconductor devices occurs at 60° zone transition. To suppress this current surge, the carriers used in the ZVS PWM scheme are phase shifted. Finally, the novel ZVS PWM scheme is verified on a 10 kW/150 kHz SiC-based ZVS T-type inverter prototype.
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (3) , 3951-3964
A ZVS-PWM Scheme for Three-Phase Active-Clamping T-Type Inverters
For increasing power density and other performance of T-type three-level inverters, the soft-switching technique is studied. This article proposes a novel zero-voltage switching (ZVS) PWM scheme for active clamping three-phase T-type inverters, which can realize the ZVS operation of all switches and reduce the switching loss. The proposed ZVS PWM scheme is evolved from discontinuous PWM and modified for the requirements of T-type inverter. It enables all switches, including main switches and auxiliary switches, operate at a fixed frequency. However, a larger current on the power semiconductor devices occurs at 60° zone transition. To suppress this current surge, the carriers used in the ZVS PWM scheme are phase shifted. Finally, the novel ZVS PWM scheme is verified on a 10 kW/150 kHz SiC-based ZVS T-type inverter prototype.
- Open Access
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 3, 75-83
A Fixed Frequency Zero-Voltage-Switching On-Board EV Charger
For electric vehicle (EV) onboard charging, high efficiency and power density of the charger is required. Soft switching technique is an effective way to increase On-Board Charger (OBC) power density and efficiency. This paper presents a fixed frequency zero-voltage-switching OBC topology which can realize Zero-Voltage-Switching (ZVS) of all the power semiconductor devices. An auxiliary resonant branch is used to realize Zero-Voltage-Switching for both front-end full-bridge rectifier and phase-shift full-bridge dc-dc converter. A novel PWM scheme is proposed for the OBC topology. ZVS conditions are derived. Finally, the proposed OBC is verified by the experiment.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 3, 75-83
Open AccessA Fixed Frequency Zero-Voltage-Switching On-Board EV Charger
For electric vehicle (EV) onboard charging, high efficiency and power density of the charger is required. Soft switching technique is an effective way to increase On-Board Charger (OBC) power density and efficiency. This paper presents a fixed frequency zero-voltage-switching OBC topology which can realize Zero-Voltage-Switching (ZVS) of all the power semiconductor devices. An auxiliary resonant branch is used to realize Zero-Voltage-Switching for both front-end full-bridge rectifier and phase-shift full-bridge dc-dc converter. A novel PWM scheme is proposed for the OBC topology. ZVS conditions are derived. Finally, the proposed OBC is verified by the experiment.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 92-99
DC-link voltage control strategy of a bi-directional DC/DC converter for electric vehicles
In electric vehicle (EV) systems, bi-directional DC/DC converters are applied to interface the battery bank with the high voltage DC-link of the inverter. The control of the DC-link voltage is important for the high performance of the system. A DC-link voltage control strategy for the bidirectional DC/DC converter is proposed, which eliminates the need for detecting the operating mode and do not need to change the control loop when the modes transfer between the motor driving mode and the regenerative braking mode. The dynamic model of the bi-directional DC/DC converter with the constant power load is built. Afterward design of the proposed control is presented. Finally, a prototype is built to validate the proposed DC-link voltage control strategy and evaluate the dynamic performance.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 92-99
DC-link voltage control strategy of a bi-directional DC/DC converter for electric vehicles
In electric vehicle (EV) systems, bi-directional DC/DC converters are applied to interface the battery bank with the high voltage DC-link of the inverter. The control of the DC-link voltage is important for the high performance of the system. A DC-link voltage control strategy for the bidirectional DC/DC converter is proposed, which eliminates the need for detecting the operating mode and do not need to change the control loop when the modes transfer between the motor driving mode and the regenerative braking mode. The dynamic model of the bi-directional DC/DC converter with the constant power load is built. Afterward design of the proposed control is presented. Finally, a prototype is built to validate the proposed DC-link voltage control strategy and evaluate the dynamic performance.