Max Engler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Max Engler has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Hoppe
Universitatsklinikum Erlangen, Germany
3 shared publications - Cynthia Glaubitz
CICERO Cochlear Implant Center, ENT–clinic of the University of Erlangen–Nuremberg, Erlangen, Germany
2 shared publications - Effi Katharina Lehmann
CICERO Cochlear Implant Center, ENT–clinic of the University of Erlangen–Nuremberg, Erlangen, Germany
2 shared publications Frank Digeser
Department of Audiology, ENT Clinic, University of Erlangen-Nürnberg
2 shared publications- Katharina Heinze
CICERO Cochlear Implant Center, ENT–clinic of the University of Erlangen–Nuremberg, Erlangen, Germany
2 shared publications - Tim Liebscher
CICERO Cochlear Implant Center, ENT–clinic of the University of Erlangen–Nuremberg, Erlangen, Germany
2 shared publications
Latest Publications
- Open Access
- 3 January 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (2) , 991
Correction: Illness perceptions in cochlear implant users – a longitudinal study
- 3 January 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (2) , 991
Open AccessCorrection: Illness perceptions in cochlear implant users – a longitudinal study
- 10 December 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (7) , 834-845
Speech recognition and real-ear-measured amplification in hearing-aid users with various grades of hearing loss
The relationship between aided speech recognition and hearing-aid (HA) amplification was investigated in a retrospective study. Pure-tone thresholds, aided and unaided speech recognition and real-ear measurements of 635 ears in 374 HA users were reviewed. Ears were classified according to pure-tone average (PTA) and real-ear aided response (REAR) in relation to the targets of NAL-NL2 and DSL v5.0. For DSL v5.0, compared with NAL-NL2, higher amplification was calculated almost consistently for input levels of 65 and 80 dB SPL. Speech-recognition scores were best when the REAR reached ±5 dB or exceeded 5 dB the DSL v5.0 target and were lowest when the REAR fell more than 5 dB below the NAL-NL2 target. The greatest impact of the REAR on speech recognition was observed at hearing losses between 50 and 80 dB HL. It was found that to optimise speech recognition and audibility for patients in this range HA fittings should target DSL v5.0 prescription values. For hearing losses below 50 dB HL, both NAL-NL2 and DSL v5.0 may be considered for HA fitting. However, for hearing losses above 80 dB HL, aided speech recognition is insufficient in most cases.
- 10 December 2024
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 65 (7) , 834-845
Speech recognition and real-ear-measured amplification in hearing-aid users with various grades of hearing loss
The relationship between aided speech recognition and hearing-aid (HA) amplification was investigated in a retrospective study. Pure-tone thresholds, aided and unaided speech recognition and real-ear measurements of 635 ears in 374 HA users were reviewed. Ears were classified according to pure-tone average (PTA) and real-ear aided response (REAR) in relation to the targets of NAL-NL2 and DSL v5.0. For DSL v5.0, compared with NAL-NL2, higher amplification was calculated almost consistently for input levels of 65 and 80 dB SPL. Speech-recognition scores were best when the REAR reached ±5 dB or exceeded 5 dB the DSL v5.0 target and were lowest when the REAR fell more than 5 dB below the NAL-NL2 target. The greatest impact of the REAR on speech recognition was observed at hearing losses between 50 and 80 dB HL. It was found that to optimise speech recognition and audibility for patients in this range HA fittings should target DSL v5.0 prescription values. For hearing losses below 50 dB HL, both NAL-NL2 and DSL v5.0 may be considered for HA fitting. However, for hearing losses above 80 dB HL, aided speech recognition is insufficient in most cases.
- Open Access
- 19 September 2024
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (2) , 981-989
Illness perceptions in cochlear implant users – a longitudinal study
Purpose ‘Illness perceptions’ refers to the thoughts and ideas a person has about an illness. According to Leventhal’s Self-Regulatory Model (SRM), changing the threatening illness perceptions of cochlear implant (CI) recipients can be a further step in optimizing hearing outcomes with the CI. The aims of the present study were to assess users’ illness perceptions and to determine whether perceptions change during six months of CI rehabilitation. Methods One hundred and thirty-eight participants completed the Brief Illness Perception Questionnaire (Brief IPQ), assessing their illness perceptions on nine scales. Data were collected at a German CI center at first CI fitting and six-month follow-up. After first fitting, participants underwent intensive rehabilitation including auditory training, medical, audiological and psychological treatments. Results At both assessments, participants tended to view their hearing impairment as a severe threat. On the Brief IPQ, the ‘consequences’ assessment improved during CI rehabilitation, which can be explained by the CI-induced hearing improvement. However, ‘understanding’ and ‘identity’ assessments worsened. This could be because CI recipients only come to realize the full complexity of their hearing impairment during rehabilitation. The other scales and the total score remained unaffected. Conclusions Current practice in CI rehabilitation seems to be insufficient to improve threatening illness perceptions (except for perceived consequences). This may be because standard information often fails to reach the patients. The development and empirical validation of an intervention program to address individual illness perceptions in CI recipients could be helpful in this context. Further research will be needed to confirm the results.
- 19 September 2024
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 282 (2) , 981-989
Open AccessIllness perceptions in cochlear implant users – a longitudinal study
Purpose ‘Illness perceptions’ refers to the thoughts and ideas a person has about an illness. According to Leventhal’s Self-Regulatory Model (SRM), changing the threatening illness perceptions of cochlear implant (CI) recipients can be a further step in optimizing hearing outcomes with the CI. The aims of the present study were to assess users’ illness perceptions and to determine whether perceptions change during six months of CI rehabilitation. Methods One hundred and thirty-eight participants completed the Brief Illness Perception Questionnaire (Brief IPQ), assessing their illness perceptions on nine scales. Data were collected at a German CI center at first CI fitting and six-month follow-up. After first fitting, participants underwent intensive rehabilitation including auditory training, medical, audiological and psychological treatments. Results At both assessments, participants tended to view their hearing impairment as a severe threat. On the Brief IPQ, the ‘consequences’ assessment improved during CI rehabilitation, which can be explained by the CI-induced hearing improvement. However, ‘understanding’ and ‘identity’ assessments worsened. This could be because CI recipients only come to realize the full complexity of their hearing impairment during rehabilitation. The other scales and the total score remained unaffected. Conclusions Current practice in CI rehabilitation seems to be insufficient to improve threatening illness perceptions (except for perceived consequences). This may be because standard information often fails to reach the patients. The development and empirical validation of an intervention program to address individual illness perceptions in CI recipients could be helpful in this context. Further research will be needed to confirm the results.
- Open Access
- 21 January 2022
- Published by Springer Nature in HNO
- Vol. 70 (7) , 520-532
Wirksamkeit der Hörgeräteversorgung bei hochgradigem Hörverlust
Zusammenfassung: Hintergrund: In der Praxis liegt das unilaterale Einsilberverstehen mit Hörgerät bei 65 dB SPL (EV 65 (HG)) häufig unter dem maximalen Einsilberverstehen aus dem Sprachaudiogramm (mEV), insbesondere bei Hörgeräteträgern mit hochgradigem Hörverlust. Diese Arbeit zielte darauf ab, den Wirkungsgrad Q der Hörgeräteversorgung, den Quotienten aus EV 65 (HG) und mEV, bei Hörgeräteträgern mit hochgradigem bis an Taubheit grenzendem Hörverlust zu untersuchen. Material und Methoden: Es wurden Daten aus In-situ-Messungen, dem Reinton- und Sprachaudiogramm und dem Sprachverstehen mit und ohne Hörgerät von 93 Ohren von 64 Patienten ausgewertet. Die Patienten stellten sich im Jahr 2019 für eine Hörgerätekontrolle in unserem Hörzentrum vor. Es wurden die Abweichung der in-situ gemessenen frequenzabhängigen Ausgangspegelwerte von den Zielvorgaben der präskriptiven Anpassformeln NAL-NL2 und DSL v5.0 analysiert. Für die Parameter EV 65 (HG) und Q wurden jeweils die Spearman-Korrelationskoeffizienten für den Sprachverständlichkeitsindex (SII) berechnet. Ergebnisse: Bei mehr als 67 % der Hörgeräteeinstellungen stimmten die Ausgangspegelwerte mit den Zielkurven für NAL-NL2 oder DSL v5.0 im Bereich von ±5 dB für Frequenzen von 0,5 bis 4 kHz für 65 dB SPL überein. Trotzdem wurde das mEV mit Hörgerät bei 65 dB SPL nicht erreicht (mittlere Abweichungen: 34,4 %). EV 65 (HG) und Q waren jedoch am besten, wenn Zielwerte für DSL v5.0 bei 65 dB SPL erreicht wurden, was mit einem höheren SII einhergeht. Schlussfolgerung: Für Hörgeräteträger mit hochgradigem bis an Taubheit grenzendem Hörverlust führen die Anpassformeln NAL-NL2 und DSL v5.0 nicht zu einer solchen Verstärkung, dass bei Alltagssprache von 65 dB SPL das mEV erreicht wird. Es bleibt zu untersuchen, ob alternative Präskriptionen mit besserer Hörbarkeit für Eingangspegel von 50 und 65 dB SPL den Wirkungsgrad der Hörgeräteversorgung verbessern könnten.
- 21 January 2022
- Published by Springer Nature in HNO
- Vol. 70 (7) , 520-532
Open AccessWirksamkeit der Hörgeräteversorgung bei hochgradigem Hörverlust
Zusammenfassung: Hintergrund: In der Praxis liegt das unilaterale Einsilberverstehen mit Hörgerät bei 65 dB SPL (EV 65 (HG)) häufig unter dem maximalen Einsilberverstehen aus dem Sprachaudiogramm (mEV), insbesondere bei Hörgeräteträgern mit hochgradigem Hörverlust. Diese Arbeit zielte darauf ab, den Wirkungsgrad Q der Hörgeräteversorgung, den Quotienten aus EV 65 (HG) und mEV, bei Hörgeräteträgern mit hochgradigem bis an Taubheit grenzendem Hörverlust zu untersuchen. Material und Methoden: Es wurden Daten aus In-situ-Messungen, dem Reinton- und Sprachaudiogramm und dem Sprachverstehen mit und ohne Hörgerät von 93 Ohren von 64 Patienten ausgewertet. Die Patienten stellten sich im Jahr 2019 für eine Hörgerätekontrolle in unserem Hörzentrum vor. Es wurden die Abweichung der in-situ gemessenen frequenzabhängigen Ausgangspegelwerte von den Zielvorgaben der präskriptiven Anpassformeln NAL-NL2 und DSL v5.0 analysiert. Für die Parameter EV 65 (HG) und Q wurden jeweils die Spearman-Korrelationskoeffizienten für den Sprachverständlichkeitsindex (SII) berechnet. Ergebnisse: Bei mehr als 67 % der Hörgeräteeinstellungen stimmten die Ausgangspegelwerte mit den Zielkurven für NAL-NL2 oder DSL v5.0 im Bereich von ±5 dB für Frequenzen von 0,5 bis 4 kHz für 65 dB SPL überein. Trotzdem wurde das mEV mit Hörgerät bei 65 dB SPL nicht erreicht (mittlere Abweichungen: 34,4 %). EV 65 (HG) und Q waren jedoch am besten, wenn Zielwerte für DSL v5.0 bei 65 dB SPL erreicht wurden, was mit einem höheren SII einhergeht. Schlussfolgerung: Für Hörgeräteträger mit hochgradigem bis an Taubheit grenzendem Hörverlust führen die Anpassformeln NAL-NL2 und DSL v5.0 nicht zu einer solchen Verstärkung, dass bei Alltagssprache von 65 dB SPL das mEV erreicht wird. Es bleibt zu untersuchen, ob alternative Präskriptionen mit besserer Hörbarkeit für Eingangspegel von 50 und 65 dB SPL den Wirkungsgrad der Hörgeräteversorgung verbessern könnten.