Masashi Miyazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masashi Miyazaki has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Toshiki Takamizawa
Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
9 shared publications - Ryo Ishii
Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
4 shared publications Ryota Aoki
Department of Operative Dentistry Nihon University School of Dentistry Tokyo Japan
4 shared publications- Atsushi Kamimoto
Department of Comprehensive Dentistry and Clinical Education Nihon University School of Dentistry Tokyo Japan
3 shared publications - Mark Andrew Latta
Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
3 shared publications - Akimasa Tsujimoto
Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University, Nagoya 464-8651, Japan
2 shared publications
Latest Publications
- 21 April 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (9) , 1610-1618
Fatigue fracture resistance of a short fiber-reinforced flowable resin composite in single-layer and incremental-layer blocks
- 21 April 2026
- Published by Elsevier in Dental Materials
- Vol. 42 (9) , 1610-1618
Fatigue fracture resistance of a short fiber-reinforced flowable resin composite in single-layer and incremental-layer blocks
- 17 April 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1681-1691
Long‐Term Whitening Stability in Combined In‐Office and At‐Home Whitening Protocols: A Randomized Controlled Clinical Trial
Objective: This clinical study assessed the color stability of combined whitening protocols for up to 2 years when using prefilled at‐home whitening trays during intervals between in‐office whitening sessions.Materials and Methods: In‐office whitening containing 35% hydrogen peroxide was used. A prefilled tray with 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six participants were randomly assigned to three groups: group I, at‐home whitening was performed 10 times between three in‐office whitening sessions; group II, at‐home whitening was performed five times between three in‐office whitening sessions; group III, only in‐office whitening (three sessions) was performed. Tooth color was assessed before whitening treatment and at 1‐day, 3‐month, 6‐month, 1‐year, and 2‐year follow‐ups using a spectrophotometer. The color differences between the color before whitening and at each follow‐up measurement were evaluated based on CIELAB ΔE*ab, CIE DE2000 ΔE 00, and ΔW ID.Results: Although the ΔE*ab and ΔE 00 in all groups gradually decreased over time, the color stabilities vary in different whitening techniques. Groups II and III showed significantly decreased ΔW ID (p < 0.05) in the early follow‐up periods when compared with that of group I.Conclusions: The use of both in‐office whitening and at‐home whitening using prefilled trays resulted in longer‐lasting whitening efficacy than in‐office whitening alone.
- 17 April 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1681-1691
Long‐Term Whitening Stability in Combined In‐Office and At‐Home Whitening Protocols: A Randomized Controlled Clinical Trial
Objective: This clinical study assessed the color stability of combined whitening protocols for up to 2 years when using prefilled at‐home whitening trays during intervals between in‐office whitening sessions.Materials and Methods: In‐office whitening containing 35% hydrogen peroxide was used. A prefilled tray with 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six participants were randomly assigned to three groups: group I, at‐home whitening was performed 10 times between three in‐office whitening sessions; group II, at‐home whitening was performed five times between three in‐office whitening sessions; group III, only in‐office whitening (three sessions) was performed. Tooth color was assessed before whitening treatment and at 1‐day, 3‐month, 6‐month, 1‐year, and 2‐year follow‐ups using a spectrophotometer. The color differences between the color before whitening and at each follow‐up measurement were evaluated based on CIELAB ΔE*ab, CIE DE2000 ΔE 00, and ΔW ID.Results: Although the ΔE*ab and ΔE 00 in all groups gradually decreased over time, the color stabilities vary in different whitening techniques. Groups II and III showed significantly decreased ΔW ID (p < 0.05) in the early follow‐up periods when compared with that of group I.Conclusions: The use of both in‐office whitening and at‐home whitening using prefilled trays resulted in longer‐lasting whitening efficacy than in‐office whitening alone.
- 14 July 2024
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (2) , 423-439
Influence of in‐office whitening on the color matching and surface characteristics of single‐shade resin composites
Objective: The color matching of single‐shade resin composites after in‐office whitening was investigated.Materials and Methods: Four single‐shade resin composites were used. A total of 35% hydrogen peroxide was used as the whitening agent. The resin composite was placed in a cavity of an artificially discolored bovine tooth. The color differences between the restoration and surrounding enamel before and after whitening were determined based on ΔE*ab, ΔE00, and ΔWID. The color stability, surface roughness (Sa), and surface gloss (GU) of the resin composite alone were also evaluated. Statistical analyses were performed using repeated‐measures analysis of variance with the Tukey–Kramer test.Results: Based on the 50:50% of perceptibility and acceptability thresholds of ΔE*ab and ΔE00, none of the resin composite restorations were clinically acceptable before or after whitening. Regarding ΔWID, although all resin composites showed “acceptable match” in the baseline, they showed “mismatch” after the third session of whitening. Most of the resin composites alone were stable in color against whitening.Conclusions: Although the single‐shade resin composites failed to achieve the expected color matching on discolored teeth either before or after the whitening, the impact of the whitening on the color of the resin composite alone may be negligible.
- 14 July 2024
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (2) , 423-439
Influence of in‐office whitening on the color matching and surface characteristics of single‐shade resin composites
Objective: The color matching of single‐shade resin composites after in‐office whitening was investigated.Materials and Methods: Four single‐shade resin composites were used. A total of 35% hydrogen peroxide was used as the whitening agent. The resin composite was placed in a cavity of an artificially discolored bovine tooth. The color differences between the restoration and surrounding enamel before and after whitening were determined based on ΔE*ab, ΔE00, and ΔWID. The color stability, surface roughness (Sa), and surface gloss (GU) of the resin composite alone were also evaluated. Statistical analyses were performed using repeated‐measures analysis of variance with the Tukey–Kramer test.Results: Based on the 50:50% of perceptibility and acceptability thresholds of ΔE*ab and ΔE00, none of the resin composite restorations were clinically acceptable before or after whitening. Regarding ΔWID, although all resin composites showed “acceptable match” in the baseline, they showed “mismatch” after the third session of whitening. Most of the resin composites alone were stable in color against whitening.Conclusions: Although the single‐shade resin composites failed to achieve the expected color matching on discolored teeth either before or after the whitening, the impact of the whitening on the color of the resin composite alone may be negligible.
- Open Access
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 179-190
Scanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 179-190
Open AccessScanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
- 8 March 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 35 (6) , 821-833
Whitening efficacy and tooth sensitivity in a combined in‐office and at‐home whitening protocol: A randomized controlled clinical trial
Objective: This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at‐home whitening trays were used between in‐office whitening intervals.Materials and Methods: An in‐office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six subjects were randomly assigned to three groups. Group I: at‐home whitening was performed 10 times between the in‐office whitening treatments. Group II: at‐home whitening was performed five times between the in‐office whitening treatments. Group III: only in‐office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity.Results: All the groups showed increased ΔE*ab, ΔE00, and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00, and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening.Conclusions: Although dual whitening with the prefilled tray and in‐office whitening had higher whitening ability than in‐office whitening alone, the intensity and absolute risk of tooth sensitivity was similar.Clinical Relevance: The dual whitening might produce faster and stronger whitening effects than in‐office whitening alone.
- 8 March 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 35 (6) , 821-833
Whitening efficacy and tooth sensitivity in a combined in‐office and at‐home whitening protocol: A randomized controlled clinical trial
Objective: This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at‐home whitening trays were used between in‐office whitening intervals.Materials and Methods: An in‐office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six subjects were randomly assigned to three groups. Group I: at‐home whitening was performed 10 times between the in‐office whitening treatments. Group II: at‐home whitening was performed five times between the in‐office whitening treatments. Group III: only in‐office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity.Results: All the groups showed increased ΔE*ab, ΔE00, and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00, and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening.Conclusions: Although dual whitening with the prefilled tray and in‐office whitening had higher whitening ability than in‐office whitening alone, the intensity and absolute risk of tooth sensitivity was similar.Clinical Relevance: The dual whitening might produce faster and stronger whitening effects than in‐office whitening alone.
- 26 April 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (3) , e12868
Influence of bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer
This study investigated the effect of the bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer. The bonding durability of a universal adhesive was compared with those of two conventional two‐step adhesives by shear bond strength testing after thermal cycling. The primer was applied (with or without phosphoric acid pre‐etching), and the specimens were divided into three groups based on the bonding agent application method used as follows: (i) strong air‐flow application, (ii) gentle air‐flow application, and (iii) gentle air‐flow + second bonding application. The shear bond strength was determined after thermal cycling. All the factors (bonding agent application method, adhesive system, and storage condition) significantly influenced the dentin shear bond strength both with and without phosphoric acid pre‐etching. The specimens exposed to gentle air‐flow showed a higher shear bond strength than did those exposed to strong air‐flow and gentle air‐flow + second bonding. The bond durability of the tested adhesive systems was influenced by the bonding agent application method, and this trend was material dependent. The G2‐Bond Universal exhibited the same or greater dentin bond durability to the other two‐step adhesive systems.
- 26 April 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (3) , e12868
Influence of bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer
This study investigated the effect of the bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer. The bonding durability of a universal adhesive was compared with those of two conventional two‐step adhesives by shear bond strength testing after thermal cycling. The primer was applied (with or without phosphoric acid pre‐etching), and the specimens were divided into three groups based on the bonding agent application method used as follows: (i) strong air‐flow application, (ii) gentle air‐flow application, and (iii) gentle air‐flow + second bonding application. The shear bond strength was determined after thermal cycling. All the factors (bonding agent application method, adhesive system, and storage condition) significantly influenced the dentin shear bond strength both with and without phosphoric acid pre‐etching. The specimens exposed to gentle air‐flow showed a higher shear bond strength than did those exposed to strong air‐flow and gentle air‐flow + second bonding. The bond durability of the tested adhesive systems was influenced by the bonding agent application method, and this trend was material dependent. The G2‐Bond Universal exhibited the same or greater dentin bond durability to the other two‐step adhesive systems.
- 24 January 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (2) , e12854
Immediate bond performance of resin composite luting systems to saliva‐contaminated enamel and dentin in different curing modes
The purpose of this study was to evaluate the immediate shear bond strength of resin composite luting systems to tooth with or without saliva contamination in different curing modes. The Knoop hardness number of the resin composite luting agents was measured. Four combinations of resin composite luting systems were used. The shear bond strength to bovine teeth was measured with and without saliva contamination in different curing modes at different storage periods. The Knoop hardness number of the resin composite luting agents was also evaluated. Significantly lower enamel and dentin shear bond strengths and Knoop hardness number values were observed in all resin composite luting systems at 5 min versus 24 h, regardless of the curing mode or saliva contamination. The influence of the curing mode of the resin composite luting systems on shear bond strengths and Knoop hardness number was dependent on material. For the saliva contamination conditions, only G‐CEM ONE EM did not show any significant difference in shear bond strength among the groups with and without saliva contamination, regardless of curing mode, storage period, or tooth substrate. All the resin composite luting systems showed lower shear bond strengths and Knoop hardness number values immediately after setting.
- 24 January 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (2) , e12854
Immediate bond performance of resin composite luting systems to saliva‐contaminated enamel and dentin in different curing modes
The purpose of this study was to evaluate the immediate shear bond strength of resin composite luting systems to tooth with or without saliva contamination in different curing modes. The Knoop hardness number of the resin composite luting agents was measured. Four combinations of resin composite luting systems were used. The shear bond strength to bovine teeth was measured with and without saliva contamination in different curing modes at different storage periods. The Knoop hardness number of the resin composite luting agents was also evaluated. Significantly lower enamel and dentin shear bond strengths and Knoop hardness number values were observed in all resin composite luting systems at 5 min versus 24 h, regardless of the curing mode or saliva contamination. The influence of the curing mode of the resin composite luting systems on shear bond strengths and Knoop hardness number was dependent on material. For the saliva contamination conditions, only G‐CEM ONE EM did not show any significant difference in shear bond strength among the groups with and without saliva contamination, regardless of curing mode, storage period, or tooth substrate. All the resin composite luting systems showed lower shear bond strengths and Knoop hardness number values immediately after setting.
- Open Access
- 1 January 2018
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 37 (1) , 113-121
Influence of the number of cycles on shear fatigue strength of resin composite bonded to enamel and dentin using dental adhesives in self-etching mode
The influence of the number of cycles on shear fatigue strength to enamel and dentin using dental adhesives in self-etch mode was investigated. A two-step self-etch adhesive and two universal adhesives were used to bond to enamel and dentin in self-etch mode. Initial shear bond strength and shear fatigue strength to enamel and dentin using the adhesive in self-etch mode were determined. Fatigue testing was used with 20 Hz frequency and cycling periods of 50,000, 100,000 and 1,000,000 cycles, or until failure occurred. For each of the cycling periods, there was no significant difference in shear fatigue strength across the cycling periods for the individual adhesives. Differences in shear fatigue strength were found between the adhesives within the cycling periods. Regardless of the adhesive used in self-etch mode for bonding to enamel or dentin, shear fatigue strength was not influenced by the number of cycles used for shear fatigue strength testing.
- 1 January 2018
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 37 (1) , 113-121
Open AccessInfluence of the number of cycles on shear fatigue strength of resin composite bonded to enamel and dentin using dental adhesives in self-etching mode
The influence of the number of cycles on shear fatigue strength to enamel and dentin using dental adhesives in self-etch mode was investigated. A two-step self-etch adhesive and two universal adhesives were used to bond to enamel and dentin in self-etch mode. Initial shear bond strength and shear fatigue strength to enamel and dentin using the adhesive in self-etch mode were determined. Fatigue testing was used with 20 Hz frequency and cycling periods of 50,000, 100,000 and 1,000,000 cycles, or until failure occurred. For each of the cycling periods, there was no significant difference in shear fatigue strength across the cycling periods for the individual adhesives. Differences in shear fatigue strength were found between the adhesives within the cycling periods. Regardless of the adhesive used in self-etch mode for bonding to enamel or dentin, shear fatigue strength was not influenced by the number of cycles used for shear fatigue strength testing.
- Open Access
- 1 January 2004
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 23 (3) , 284-290
Application of the Laser Speckle-Correlation Method for Determining the Shrinkage Vector of a Light-cured Resin
The purpose of this study was to develop a method to monitor the free-shrinkage vectors of a light-cured resin using laser speckle contrast measurement. The laser speckle contrast measurement system comprised a semiconductor laser, a speckle analyzer, and a computer-controlled data acquisition system. A light-cured resin was condensed into a glass tube and irradiated using a curing unit, the light intensity of which was adjusted to either 100 or 600mW/cm2. The speckle patterns obtained from the lateral surface of the specimen were monitored using a CCD camera connected to a computer. The speckle images were analyzed using a phase-only correlation algorithm, and movements of the pattern were traced. The speckle pattern revealed rapid movement almost immediately after light exposure was initiated, and the orientation of free-shrinkage vectors is dependent on light intensity. When the specimens were irradiated at the lower light intensity, the free shrinkage vectors were oriented towards the light source. On the other hand, when irradiated at the higher light intensity, the free-shrinkage vectors of these specimens tended to orient towards the bottom surface. The effectiveness of the employed method to determine free-shrinkage vectors is thus proven through the results of this study.
- 1 January 2004
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 23 (3) , 284-290
Open AccessApplication of the Laser Speckle-Correlation Method for Determining the Shrinkage Vector of a Light-cured Resin
The purpose of this study was to develop a method to monitor the free-shrinkage vectors of a light-cured resin using laser speckle contrast measurement. The laser speckle contrast measurement system comprised a semiconductor laser, a speckle analyzer, and a computer-controlled data acquisition system. A light-cured resin was condensed into a glass tube and irradiated using a curing unit, the light intensity of which was adjusted to either 100 or 600mW/cm2. The speckle patterns obtained from the lateral surface of the specimen were monitored using a CCD camera connected to a computer. The speckle images were analyzed using a phase-only correlation algorithm, and movements of the pattern were traced. The speckle pattern revealed rapid movement almost immediately after light exposure was initiated, and the orientation of free-shrinkage vectors is dependent on light intensity. When the specimens were irradiated at the lower light intensity, the free shrinkage vectors were oriented towards the light source. On the other hand, when irradiated at the higher light intensity, the free-shrinkage vectors of these specimens tended to orient towards the bottom surface. The effectiveness of the employed method to determine free-shrinkage vectors is thus proven through the results of this study.