Atsushi Kamimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Atsushi Kamimoto has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Masashi Miyazaki
Department of Operative Dentistry Nihon University School of Dentistry Tokyo Japan
3 shared publications - Toshiki Takamizawa
Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
3 shared publications - Munenori Yokoyama
Department of Operative Dentistry Nihon University School of Dentistry Tokyo Japan
2 shared publications Ryota Aoki
Department of Operative Dentistry, Nihon University School of Dentistry
2 shared publicationsEizo Hirokane
Department of Operative Dentistry Nihon University School of Dentistry Tokyo Japan
1 shared publicationKana Hayashi
Department of Operative Dentistry, Nihon University School of Dentistry
1 shared publication
Latest Publications
- Open Access
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 179-190
Scanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
- 25 March 2024
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 43 (2) , 179-190
Open AccessScanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
- 8 March 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 35 (6) , 821-833
Whitening efficacy and tooth sensitivity in a combined in‐office and at‐home whitening protocol: A randomized controlled clinical trial
Objective: This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at‐home whitening trays were used between in‐office whitening intervals.Materials and Methods: An in‐office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six subjects were randomly assigned to three groups. Group I: at‐home whitening was performed 10 times between the in‐office whitening treatments. Group II: at‐home whitening was performed five times between the in‐office whitening treatments. Group III: only in‐office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity.Results: All the groups showed increased ΔE*ab, ΔE00, and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00, and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening.Conclusions: Although dual whitening with the prefilled tray and in‐office whitening had higher whitening ability than in‐office whitening alone, the intensity and absolute risk of tooth sensitivity was similar.Clinical Relevance: The dual whitening might produce faster and stronger whitening effects than in‐office whitening alone.
- 8 March 2023
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 35 (6) , 821-833
Whitening efficacy and tooth sensitivity in a combined in‐office and at‐home whitening protocol: A randomized controlled clinical trial
Objective: This controlled randomized clinical trial determined the whitening efficacy and the intensity and absolute risk of tooth sensitivity in dual whitening when prefilled at‐home whitening trays were used between in‐office whitening intervals.Materials and Methods: An in‐office whitening agent containing 35% hydrogen peroxide was used. A prefilled tray with a whitening agent containing 6% hydrogen peroxide was used for at‐home whitening. Sixty‐six subjects were randomly assigned to three groups. Group I: at‐home whitening was performed 10 times between the in‐office whitening treatments. Group II: at‐home whitening was performed five times between the in‐office whitening treatments. Group III: only in‐office whitening was performed. The tooth color changes were evaluated using a spectrophotometer. A visual analog scale was used to express the pain intensity.Results: All the groups showed increased ΔE*ab, ΔE00, and ΔWID with increased whitening sessions. Group I at the 3rd whitening session showed significantly higher ΔE*ab, ΔE00, and ΔWID than group III. Tooth sensitivity showed higher values up to 24 h after whitening.Conclusions: Although dual whitening with the prefilled tray and in‐office whitening had higher whitening ability than in‐office whitening alone, the intensity and absolute risk of tooth sensitivity was similar.Clinical Relevance: The dual whitening might produce faster and stronger whitening effects than in‐office whitening alone.
- Open Access
- 8 November 2022
- Published by Elsevier in Journal of Dental Sciences
- Vol. 18 (2) , 911-912
Periapical granuloma with actinomycosis and medication-related osteonecrosis of the jaw in a patient prescribed high-dose ibandronate
- 8 November 2022
- Published by Elsevier in Journal of Dental Sciences
- Vol. 18 (2) , 911-912
Open AccessPeriapical granuloma with actinomycosis and medication-related osteonecrosis of the jaw in a patient prescribed high-dose ibandronate
- 26 April 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (3) , e12868
Influence of bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer
This study investigated the effect of the bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer. The bonding durability of a universal adhesive was compared with those of two conventional two‐step adhesives by shear bond strength testing after thermal cycling. The primer was applied (with or without phosphoric acid pre‐etching), and the specimens were divided into three groups based on the bonding agent application method used as follows: (i) strong air‐flow application, (ii) gentle air‐flow application, and (iii) gentle air‐flow + second bonding application. The shear bond strength was determined after thermal cycling. All the factors (bonding agent application method, adhesive system, and storage condition) significantly influenced the dentin shear bond strength both with and without phosphoric acid pre‐etching. The specimens exposed to gentle air‐flow showed a higher shear bond strength than did those exposed to strong air‐flow and gentle air‐flow + second bonding. The bond durability of the tested adhesive systems was influenced by the bonding agent application method, and this trend was material dependent. The G2‐Bond Universal exhibited the same or greater dentin bond durability to the other two‐step adhesive systems.
- 26 April 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (3) , e12868
Influence of bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer
This study investigated the effect of the bonding agent application method on the dentin bond durability of a two‐step adhesive utilizing a universal‐adhesive‐derived primer. The bonding durability of a universal adhesive was compared with those of two conventional two‐step adhesives by shear bond strength testing after thermal cycling. The primer was applied (with or without phosphoric acid pre‐etching), and the specimens were divided into three groups based on the bonding agent application method used as follows: (i) strong air‐flow application, (ii) gentle air‐flow application, and (iii) gentle air‐flow + second bonding application. The shear bond strength was determined after thermal cycling. All the factors (bonding agent application method, adhesive system, and storage condition) significantly influenced the dentin shear bond strength both with and without phosphoric acid pre‐etching. The specimens exposed to gentle air‐flow showed a higher shear bond strength than did those exposed to strong air‐flow and gentle air‐flow + second bonding. The bond durability of the tested adhesive systems was influenced by the bonding agent application method, and this trend was material dependent. The G2‐Bond Universal exhibited the same or greater dentin bond durability to the other two‐step adhesive systems.