BHBo He

Bo He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo He has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single-pulse characterization of the focal spot size of X-ray free-electron lasers using coherent diffraction imaging

    by Zichen Gao, Jiadong Fan, Yajun Tong, Jianhua Zhang, Bo He, Yonggan Nie, Hui Luan, Donghao Lu, Difei Zhang, Xinye Yuan, et al.

    The characterization of X-ray focal spots is of great significance for the diagnosis and performance optimization of focusing systems. X-ray free-electron lasers (XFELs) are the latest generation of X-ray sources with ultrahigh brilliance, ultrashort pulse duration and nearly full transverse coherence. Because each XFEL pulse is unique and has an ultrahigh peak intensity, it is difficult to characterize its focal spot size individually with full power. Herein, a method for characterizing the spot size at the focus position is proposed based on coherent diffraction imaging. A numerical simulation was conducted to verify the feasibility of the proposed method. The focal spot size of the Coherent Scattering and Imaging endstation at the Shanghai Soft X-ray Free Electron Laser Facility was characterized using the method. The full width at half-maxima of the focal spot intensity and spot size in the horizontal and vertical directions were calculated to be 2.10 ± 0.24 µm and 2.00 ± 0.20 µm, respectively. An ablation imprint on the silicon frame was used to validate the results of the proposed method.


  • Open Access

    Quantitative analysis of the effect of radiation on mitochondria structure using coherent diffraction imaging with a clustering algorithm

    by Dan Pan, Jiadong Fan, Zhenzhen Nie, Zhibin Sun, Jianhua Zhang, Yajun Tong, Bo He, Changyong Song, Yoshiki Kohmura, Makina Yabashi, et al.

    Radiation damage and a low signal-to-noise ratio are the primary factors that limit spatial resolution in coherent diffraction imaging (CDI) of biomaterials using X-ray sources. Introduced here is a clustering algorithm named ConvRe based on deep learning, and it is applied to obtain accurate and consistent image reconstruction from noisy diffraction patterns of weakly scattering biomaterials. To investigate the impact of X-ray radiation on soft biomaterials, CDI experiments were performed on mitochondria from human embryonic kidney cells using synchrotron radiation. Benefiting from the new algorithm, structural changes in the mitochondria induced by X-ray radiation damage were quantitatively characterized and analysed at the nanoscale with different radiation doses. This work also provides a promising approach for improving the imaging quality of biomaterials with XFEL-based plane-wave CDI.