YTYajun Tong

Yajun Tong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yajun Tong has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Wavefront-preserved thermal–optical design of a high-heat-load grazing-incidence X-ray mirror

    by Zhen Wang, Fang Liu, Weizhen Lei, Xiaohao Dong, Yuzhu Wang, Yajun Tong

    High-repetition-rate X-ray free-electron laser facilities impose stringent requirements on the thermal stability and wavefront preservation of beamline mirrors. In this work, a coupled thermal–optical optimization method is developed for the first reflective mirror of the FEL-III beamline at the SHINE facility under an absorbed heat load of up to 11.12 W at a photon energy of 15 keV and a repetition rate of 200 kHz, with a peak absorbed power density of 0.0718W/mm 2 . The cooling length and cooling-groove distance from the optical surface are jointly optimized, and their effects on residual height error, slope error, and focal-plane Strehl ratio are evaluated using thermal–structural analysis and X-ray tracing. The results show that the mirror performance is governed by the coupled cooling geometry rather than by either parameter alone. Compared with the initial full-length cooling design, the optimized design reduces the RMS residual height error by 73.7% and the RMS slope error by 68.9%. The system-level Strehl ratio increases from 0.45 to 0.993, exceeding the target value of 0.96, while stray-light features are suppressed and a compact focal intensity distribution is recovered at the sample plane. These results demonstrate that deformation-based thermal optimization, when combined with system-level X-ray tracing, provides an effective thermal–optical design route for preserving wavefront quality in high-heat-load grazing-incidence X-ray optical systems.

  • Open Access

    Damage study on B4C mirrors induced by single-shot x-ray free electron laser at SXFEL

    by Shuhui Li, Wenbin Li, Zhanglin Hu, Chao Yun, Danqiao Xu, Xinyi Liu, Mengmeng Zhang, Jiadong Fan, Yajun Tong, Zhen Wang, et al.

    Boron carbide (B4C) is widely used as a coating material for x-ray optics in X-ray Free Electron Laser (XFEL) beamlines. In this study, single-shot damage experiments were conducted on B4C/Si-sub and B4C/Cr/Si-sub mirrors at 517 eV using the Shanghai Soft x-ray free electron laser. The damage thresholds were determined to be 0.49 ± 0.13 and 0.32 ± 0.08 J/cm2 for B4C/Si-sub and B4C/Cr/Si-sub, respectively. Morphological and microstructural characterizations reveal that XFEL-induced damage in both samples is closely related to thermal melting of the Si substrate. Based on the silicon melting criterion, the theoretical damage threshold simulated by the finite element method for B4C/Si-sub is in good agreement with the experimental result. The bump damage morphology observed at a fluence of 0.66 J/cm2 for this sample is attributed to the volumetric expansion of the molten Si substrate. In contrast, the silicon melting criterion overestimates the damage threshold for the B4C mirror with a Cr adhesive layer. The lower experimental threshold of B4C/Cr/Si-sub is attributed to the interfacial diffusion reaction and the femtosecond XFEL-induced cavitation, which leads to a more readily observable damage morphology.

  • Experimental protocol for single-shot irradiation studies on optical materials at the SXFEL facility

    by Shuhui Li, Zhanglin Hu, Chao Yun, Zichen Gao, Danqiao Xu, Jiadong Fan, Zhen Wang, Chao Feng, Yajun Tong, Qiushi Huang, et al.

    Ultra-intense and ultra-short x-ray free-electron lasers (XFELs) impose rigorous requirements on the damage resistance of optical materials. The investigations of interactions between XFELs and optical materials are vital for both evaluating the durability of optical components applied in XFEL beamlines and elucidating the fundamental physics of light–matter interaction under extreme conditions. In this paper, we report an experimental protocol for single-shot irradiation studies on optical materials at the Shanghai Soft X-ray Free-Electron Laser (SXFEL) facility, including detailed descriptions of the XFEL beamline layout, experimental setup, incident angle calibration, pulse-energy measurement, focused FEL spot size characterization, and irradiation procedures. Following this experimental protocol, single-shot irradiation was performed on a Si wafer at the SXFEL under normal incidence. A damage threshold of 0.22 ± 0.06 J/cm2 was determined at a photon energy of 517 eV. It is in good agreement with the fluence calculated based on the melting dose of Si, confirming thermal ablation as the dominant damage mechanism.


  • Open Access

    Additive Manufacturing Based Polymer Compounded Refractive Lenses for X-Ray Focusing at Synchrotron Light Sources

    by Boyong Wang, Rongcheng Yang, Pingping Wen, Zhihao Guan, Yajun Tong, Zhi Qiao, Huaidong Jiang

    Additive manufacturing offers a promising route to low-cost, rapidly deployable X-ray focusing optics with geometries that are difficult to realize by conventional machining. Here, we report polymer compound refractive lenses (CRLs) for hard X-ray focusing fabricated by projection micro-stereolithography (PµSL, DLP-based) and by two-photon polymerization (2PP). Two-dimensional bi-parabolic CRL elements were produced in multiple photopolymer resins (HTL, Tough, ST1400 for PμSL; IP-S for 2PP) and evaluated by at-wavelength metrology at the Shanghai Synchrotron Radiation Facility. The single-lens residual phase errors (RMS) less than 0.1 λ were measured for PµSL-fabricated HTL, and Toughlenses, respectively, while 2PP-fabricated IP-S lenses achieved 0.008 λ. And the analysis indicates that PµSL lenses are primarily limited by systematic mid-order aberrations, whereas 2PP substantially suppresses coma but shows residual spherical aberration attributable to process calibration and shrinkage. Leveraging the higher fidelity of 2PP, a 65-element parabolic CRL array (radius of curvature of 100 µm) was fabricated and demonstrated hard X-ray focusing at 15 keV with focal spot sizes of 6.4 ± 1 µm (H) and 6.8 ± 1 µm (V), and a flux gain of 220. The measured performance agrees with theoretical expectations when accounting for X-ray source properties, detector resolution and chromatic aberration. These results establish a practical pathway for additively manufactured polymer CRLs with DLP and 2PP techniques as compact, customization focusing optics for synchrotron beamlines.


  • Open Access

    High-speed quantitative X-ray multi-contrast imaging with deep learning based modulated pattern analysis

    by Zhi Qiao, Yudong Yao, Hongyu Chen, Guohao Du, Pingping Wen, Zhihao Guan, Yajun Tong, Xianbo Shi, Huaidong Jiang

    The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.

  • Open Access

    Development of arrival-time diagnostic tool for X-ray pump–probe experiments at Shanghai Soft X-ray Free Electron Laser

    by Zhi Qiao, Jiadong Fan, Zichen Gao, Yonggan Nie, Pingping Wen, Xinyuan Wang, Kun Yan, Hang Ren, Boyong Wang, Jiaming Jiang, et al.

    X-ray free electron lasers (XFELs) serve as advanced light sources and have become essential for investigating ultrafast dynamic phenomena in physics and materials with extraordinary resolution. Owing to the XFEL's ultrafast characteristics and short wavelengths, an arrival-timing tool is crucial for pump–probe experiments. To address this, we have developed a timing diagnostic tool employing both spectral-encoding and spatial-imaging methods at the SBP beamline for the newly constructed Shanghai Soft X-ray Free Electron Laser Facility (SXFEL). This timing tool was experimentally validated, proving that the spectral-encoding technique could achieve single-pulse measurement with an accuracy of under 40 fs [root mean square (RMS)], and exhibited a timing-jitter measurement of 90.3 fs (RMS) at the CSI endstation of SXFEL. Furthermore, the spatial-imaging approach used both polished- and rough-surface GaAs crystals, which simplifies implementation in X-ray pump–probe experiments, and allows for the characterization of X-ray pulse arrival times at the endstation without rotating the sample stage. These findings confirm that the timing diagnostic tool provides dependable high-precision temporal characterization of X-ray pulses at SXFEL, facilitating high-accuracy X-ray pump–probe experiments.


  • Open Access

    An atomic-scale investigation of structural transitions in ruthenium induced by x-ray free-electron lasers

    by Xue Hai, Ya-Ru Yin, Ya-Jun Tong, Xiao-Feng Zhang, Han Wang, Fei-Fei Zhang, A-Li Wen, Cui-Lan Ren, Ping Huai

    The surface thermodynamic properties of ruthenium (Ru) targets were systematically investigated under different laser energy fluences to elucidate the irradiation damage mechanisms of the grazing incidence mirror in x-ray free-electron laser (XFEL) facilities, by combining the two-temperature model and molecular dynamics method. Initially, the 50 nm Ru thin film was irradiated by a 20 fs laser pulse at an absorbed laser fluence of 40 mJ cm−2, and surface dynamic processes with rapid heating and homogeneous melting lasting picosecond-timescale were observed. However, the ultra-short laser-induced surface dynamic responses in 600 nm Ru thick film were lasting much longer time. With the increasing energy fluence of the laser pulse, the intensified irradiation effects characterized by the surface morphology changes were observed, followed by homogeneous melting of the Ru thick film. As the laser fluence approaches the damage threshold, an unconventional ablation effect was observed in the irradiated thick film, featuring the formation of point defects, voids, and subsequent nanometer-scale splitting in the front surface (approximately 5 nm). It indicates that, at laser fluences ranging from 20 to 320 mJ cm−2, the surface morphology undergoes expansion at angstrom to nanometer scales, accompanied by nanoscale splitting. The results provide valuable insights into the irradiation damage mechanism of the high-Z coating materials for x-ray optics in XFELs.


  • Open Access

    Multi-segment cooling design of a reflection mirror based on the finite-element method

    by Zhen Wang, Yajun Tong, Fang Liu, Chaofan Xue, Limin Jin, Zhi Liu

    High-repetition-rate free-electron lasers impose stringent requirements on thermal deformations of optics in the beamline. The Shanghai HIgh-repetition-rate XFEL aNd Extreme light facility (SHINE) experiences high average thermal power and demands wavefront preservation. To effectively manage thermal deformation in the first reflection mirrors M1, we optimized the cooling length and position of the cooling groove with numerical calculations. For example, the root mean square of the height error of the thermal deformation of the mirror at a photon energy of 900 eV was optimized, resulting in a 12.7× reduction, from 13.76 nm to 1.08 nm. This optimized design also eliminated stray light in the focus spot at the sample and resulted in a 177% increase in the peak intensity of the beam's focus spot at the sample, from 3.08 × 105 to 8.53 × 105. The multi-segment cooling design of the mirror advanced the quality of the beam's focus spot at the sample and ensured the stable operation of SHINE under high repetition rates.


  • Open Access

    Design and first-round commissioning result of the SASE beamline at the Shanghai Soft X-ray FEL facility

    by Chaofan Xue, Zhi Guo, Haigang Liu, Jiahua Chen, Yajun Tong, Jiadong Fan, Huaidong Jiang, Zhi Liu, Ximing Zhang, Renzhong Tai

    The Shanghai Soft X-ray Free-Electron Laser (SXFEL) is the first X-ray free-electron laser facility in China. The SASE beamline, which consists of a pink-beam branch and a mono-beam branch, is one of the two beamlines in the Phase-I construction. The pink-beam branch opened for users in 2023 after successful first-round beamline commissioning. In this paper, the design of the beamline is presented and the performance of the pink-beam branch is reported. The measured energy-resolving power of the online spectrometer is over 6000 @ 400 eV. The focusing spot size of the pink beam is less than 3 µm in both the horizontal and vertical at the endstation.