Yishuang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yishuang Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Tao Lu
Department of Radiology, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
6 shared publications - Aiwen Guo
Department of Radiology, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Chengqian Wu
Department of Radiology, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Xiangqi Li
Department of Radiology, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Yan Deng
Department of Radiology, Sichuan Provincial People’s Hospital, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Guotai Wang
University of Electronic Science and Technology of China
3 shared publications
Latest Publications
- 29 November 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-40
Research process, recap, and prediction of Chiari malformation based on bicentennial history of nomenclature and terms misuse
There is an absent systematic analysis or review that has been conducted to clarify the topic of nomenclature history and terms misuse about Chiari malformations (CMs). We reviewed all reports on terms coined for CMs for rational use and provided their etymology and future development. All literature on the nomenclature of CMs was retrieved and extracted into core terms. Subsequently, keyword analysis, preceding and predicting (2023–2025) compound annual growth rate (CAGR) of each core term, was calculated using a mathematical formula and autoregressive integrated moving average model in Python. Totally 64,527 CM term usage was identified. Of these, 57 original terms were collected and then extracted into 24 core-terms. Seventeen terms have their own featured author keywords, while seven terms are homologous. The preceding CAGR of 24 terms showed significant growth in use for 18 terms, while 13, three, three, and five terms may show sustained growth, remain stable, decline, and rare in usage, respectively, in the future. Previously, owing to intricate nomenclature, Chiari terms were frequently misused, and numerous seemingly novel but worthless even improper terms have emerged. For a very basic neuropathological phenomenon tonsillar herniation by multiple etiology, a mechanism-based nosology seems to be more conducive to future communication than an umbrella eponym. However, a good nomenclature also should encapsulate all characteristics of this condition, but this is lacking in current CM research, as the pathophysiological mechanisms are not elucidated for the majority of CMs.
- 29 November 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-40
Research process, recap, and prediction of Chiari malformation based on bicentennial history of nomenclature and terms misuse
There is an absent systematic analysis or review that has been conducted to clarify the topic of nomenclature history and terms misuse about Chiari malformations (CMs). We reviewed all reports on terms coined for CMs for rational use and provided their etymology and future development. All literature on the nomenclature of CMs was retrieved and extracted into core terms. Subsequently, keyword analysis, preceding and predicting (2023–2025) compound annual growth rate (CAGR) of each core term, was calculated using a mathematical formula and autoregressive integrated moving average model in Python. Totally 64,527 CM term usage was identified. Of these, 57 original terms were collected and then extracted into 24 core-terms. Seventeen terms have their own featured author keywords, while seven terms are homologous. The preceding CAGR of 24 terms showed significant growth in use for 18 terms, while 13, three, three, and five terms may show sustained growth, remain stable, decline, and rare in usage, respectively, in the future. Previously, owing to intricate nomenclature, Chiari terms were frequently misused, and numerous seemingly novel but worthless even improper terms have emerged. For a very basic neuropathological phenomenon tonsillar herniation by multiple etiology, a mechanism-based nosology seems to be more conducive to future communication than an umbrella eponym. However, a good nomenclature also should encapsulate all characteristics of this condition, but this is lacking in current CM research, as the pathophysiological mechanisms are not elucidated for the majority of CMs.
- 15 February 2023
- Published by Springer Nature in Archives of Gynecology and Obstetrics
- Vol. 309 (2) , 503-514
Standard diffusion-weighted, diffusion kurtosis and intravoxel incoherent motion in differentiating invasive placentas
Purpose To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in distinguishing invasive placentas. Methods A total of 53 patients with invasive placentas and 47 patients with noninvasive placentas undergoing conventional diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), and diffusion kurtosis imaging (DKI) were retrospectively enrolled. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured and compared from the volumetric analysis. Receiver operating characteristics (ROC) curve and logistic regression analyses were conducted to evaluate the diagnostic efficiency of different diffusion parameters for distinguishing invasive placentas. Results Comparisons between accreta lesions in patients with invasive placentas (AL) and lower 1/3 part of the placenta in patients with noninvasive placentas (LP) demonstrated that MD mean, D mean, and D* mean were significantly lower while ADC max and D max were significantly higher in invasive placentas (all p < 0.05). Multivariate analysis demonstrated that D mean, D max and D* mean differed significantly among all the studied parameters for invasive placentas. A combined use of these three parameters yielded an AUC of 0.86 with sensitivity, specificity, and accuracy of 84.91%, 76.60%, and 80%, respectively. Conclusion The combined use of different IVIM parameters is helpful in distinguishing invasive placentas.
- 15 February 2023
- Published by Springer Nature in Archives of Gynecology and Obstetrics
- Vol. 309 (2) , 503-514
Standard diffusion-weighted, diffusion kurtosis and intravoxel incoherent motion in differentiating invasive placentas
Purpose To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in distinguishing invasive placentas. Methods A total of 53 patients with invasive placentas and 47 patients with noninvasive placentas undergoing conventional diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), and diffusion kurtosis imaging (DKI) were retrospectively enrolled. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured and compared from the volumetric analysis. Receiver operating characteristics (ROC) curve and logistic regression analyses were conducted to evaluate the diagnostic efficiency of different diffusion parameters for distinguishing invasive placentas. Results Comparisons between accreta lesions in patients with invasive placentas (AL) and lower 1/3 part of the placenta in patients with noninvasive placentas (LP) demonstrated that MD mean, D mean, and D* mean were significantly lower while ADC max and D max were significantly higher in invasive placentas (all p < 0.05). Multivariate analysis demonstrated that D mean, D max and D* mean differed significantly among all the studied parameters for invasive placentas. A combined use of these three parameters yielded an AUC of 0.86 with sensitivity, specificity, and accuracy of 84.91%, 76.60%, and 80%, respectively. Conclusion The combined use of different IVIM parameters is helpful in distinguishing invasive placentas.
- 17 September 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (12) , 4237-4244
Correlation of placental thickness and placenta percreta in patients with placenta previa: findings from MRI
Introduction This study aimed to identify if placental thickness measured from MRI images correlated with placenta percreta in patients with placenta previa. Methods Placental thickness was retrospectively measured in 161 patients from July 2018 to August 2020. The measurements were performed at the thickest part of the placenta in the lower uterine segment on the mid-sagittal plane MR images by two independent radiologists. Intraoperative and pathologic findings were the standard of reference. Univariate and multivariate analyses were performed to identify the relationship between clinical features, placental thickness, and placenta percreta. The predictive ability of placental thickness was demonstrated using receiver operating characteristic curve analysis. Results Placental thickness in patients with placenta percreta was significantly higher than in patients with placenta increta, placenta accreta, and normal placentas (p < 0.05). Multivariate analysis revealed that placental thickness was the only independent risk factor for placenta percreta. The cutoff value of placental thickness was 4.35 cm for differentiating placenta percreta in patients with placenta previa. Discussion Patients with placenta percreta had the highest placental thickness. Placental thickness was correlated with placenta percreta.
- 17 September 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (12) , 4237-4244
Correlation of placental thickness and placenta percreta in patients with placenta previa: findings from MRI
Introduction This study aimed to identify if placental thickness measured from MRI images correlated with placenta percreta in patients with placenta previa. Methods Placental thickness was retrospectively measured in 161 patients from July 2018 to August 2020. The measurements were performed at the thickest part of the placenta in the lower uterine segment on the mid-sagittal plane MR images by two independent radiologists. Intraoperative and pathologic findings were the standard of reference. Univariate and multivariate analyses were performed to identify the relationship between clinical features, placental thickness, and placenta percreta. The predictive ability of placental thickness was demonstrated using receiver operating characteristic curve analysis. Results Placental thickness in patients with placenta percreta was significantly higher than in patients with placenta increta, placenta accreta, and normal placentas (p < 0.05). Multivariate analysis revealed that placental thickness was the only independent risk factor for placenta percreta. The cutoff value of placental thickness was 4.35 cm for differentiating placenta percreta in patients with placenta previa. Discussion Patients with placenta percreta had the highest placental thickness. Placental thickness was correlated with placenta percreta.
- 8 July 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (6) , 1009-1020
Diffusion and perfusion MRI parameters in the evaluation of placenta accreta spectrum disorders in patients with placenta previa
Objectives To evaluate the placental function by monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in patients with placenta previa. Methods A total of 62 patients with placenta accreta spectrum (PAS) disorders and 11 patients with normal placentas were retrospectively enrolled, who underwent conventional diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), and diffusion kurtosis imaging (DKI). The apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, mean kurtosis (MK), and diffusion coefficient (MD) from DKI, and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured and compared from the volumetric analysis. Results Comparisons between patients with PAS disorders and patients with normal placentas demonstrated that MD mean, D mean, and D* mean values in patients with PAS disorders were significantly higher than those in patients with normal placentas (p < 0.05). Comparisons between patients with accreta, increta, and percreta, and patients with normal placentas showed that the D mean was significantly higher in patients with placenta increta and percreta than in patients with normal placentas (p < 0.05). Conclusion The accreta lesions in PAS disorders had deceased cellularity and increased blood movement. The alteration of placental cellularity was more prominent in placenta increta and percreta.
- 8 July 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (6) , 1009-1020
Diffusion and perfusion MRI parameters in the evaluation of placenta accreta spectrum disorders in patients with placenta previa
Objectives To evaluate the placental function by monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in patients with placenta previa. Methods A total of 62 patients with placenta accreta spectrum (PAS) disorders and 11 patients with normal placentas were retrospectively enrolled, who underwent conventional diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), and diffusion kurtosis imaging (DKI). The apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, mean kurtosis (MK), and diffusion coefficient (MD) from DKI, and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured and compared from the volumetric analysis. Results Comparisons between patients with PAS disorders and patients with normal placentas demonstrated that MD mean, D mean, and D* mean values in patients with PAS disorders were significantly higher than those in patients with normal placentas (p < 0.05). Comparisons between patients with accreta, increta, and percreta, and patients with normal placentas showed that the D mean was significantly higher in patients with placenta increta and percreta than in patients with normal placentas (p < 0.05). Conclusion The accreta lesions in PAS disorders had deceased cellularity and increased blood movement. The alteration of placental cellularity was more prominent in placenta increta and percreta.
- Open Access
- 22 April 2022
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 22 (1) , 1-12
Monoexponential, biexponential and diffusion kurtosis MR imaging models: quantitative biomarkers in the diagnosis of placenta accreta spectrum disorders
Background: To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in differentiating placenta accreta spectrum (PAS) disorders. Methods: A total of 65 patients with PAS disorders and 27 patients with normal placentas undergoing conventional DWI, IVIM, and DKI were retrospectively reviewed. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and mean diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured from the volumetric analysis and compared between patients with PAS disorders and patients with normal placentas. Univariate and multivariated logistic regression analyses were used to evaluate the value of the above parameters for differentiating PAS disorders. Receiver operating characteristics (ROC) curve analyses were used to evaluate the diagnostic efficiency of different diffusion parameters for predicting PAS disorders. Results: Multivariate analysis demonstrated that only D mean and D max differed significantly among all the studied parameters for differentiating PAS disorders when comparisons between accreta lesions in patients with PAS (AP) and whole placentas in patients with normal placentas (WP-normal) were performed (all p < 0.05). For discriminating PAS disorders, a combined use of these two parameters yielded an AUC of 0.93 with sensitivity, specificity, and accuracy of 83.08, 88.89, and 83.70%, respectively. Conclusion: The diagnostic performance of the parameters from accreta lesions was better than that of the whole placenta. D mean and D max were associated with PAS disorders.
- 22 April 2022
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 22 (1) , 1-12
Open AccessMonoexponential, biexponential and diffusion kurtosis MR imaging models: quantitative biomarkers in the diagnosis of placenta accreta spectrum disorders
Background: To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in differentiating placenta accreta spectrum (PAS) disorders. Methods: A total of 65 patients with PAS disorders and 27 patients with normal placentas undergoing conventional DWI, IVIM, and DKI were retrospectively reviewed. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and mean diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured from the volumetric analysis and compared between patients with PAS disorders and patients with normal placentas. Univariate and multivariated logistic regression analyses were used to evaluate the value of the above parameters for differentiating PAS disorders. Receiver operating characteristics (ROC) curve analyses were used to evaluate the diagnostic efficiency of different diffusion parameters for predicting PAS disorders. Results: Multivariate analysis demonstrated that only D mean and D max differed significantly among all the studied parameters for differentiating PAS disorders when comparisons between accreta lesions in patients with PAS (AP) and whole placentas in patients with normal placentas (WP-normal) were performed (all p < 0.05). For discriminating PAS disorders, a combined use of these two parameters yielded an AUC of 0.93 with sensitivity, specificity, and accuracy of 83.08, 88.89, and 83.70%, respectively. Conclusion: The diagnostic performance of the parameters from accreta lesions was better than that of the whole placenta. D mean and D max were associated with PAS disorders.
- 24 January 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (3) , 1150-1156
Correlation of placental thickness and PAS disorders: findings from MRI
Objective To identify if placental thickness measured from MRI images correlates with placenta accreta spectrum (PAS) disorders. Methods Placental thickness of 245 patients was retrospectively measured from October 2016 to March 2020. The measurement was made at the thickest portion of the placenta on the mid-sagittal plane of the placenta from MRI by two independent radiologists. Surgical report and pathology of the delivered placenta were used as a reference standard. Association between clinical features, placental thickness, and PAS disorders was evaluated with univariate and multivariate analyses. The inter-reader and intra-reader reproducibility of the measurements and receiver operating characteristic curve analysis were also performed. Results Placental thickness was significantly higher in patients with PAS disorders (3.45 cm) than that in patients without PAS disorders (2.90 cm) (p < 0.05). Multivariate analyses revealed that prior cesarean section, placenta previa, and placental thickness > 4 cm were independent risk factors for PAS disorders. The inter-reader and intra-reader reproducibility of placental thickness measurement were 0.979 (95% CI 0.960–0.989) and 0.981 (95% CI 0.9640–0.990), respectively. Conclusion The reproducibility of the measurement made from MRI images was high between two radiologists. Patients with PAS disorders had increased placental thickness. Placental thickness > 4 cm correlated with PAS disorders.
- 24 January 2022
- Published by Springer Nature in Abdominal Radiology
- Vol. 47 (3) , 1150-1156
Correlation of placental thickness and PAS disorders: findings from MRI
Objective To identify if placental thickness measured from MRI images correlates with placenta accreta spectrum (PAS) disorders. Methods Placental thickness of 245 patients was retrospectively measured from October 2016 to March 2020. The measurement was made at the thickest portion of the placenta on the mid-sagittal plane of the placenta from MRI by two independent radiologists. Surgical report and pathology of the delivered placenta were used as a reference standard. Association between clinical features, placental thickness, and PAS disorders was evaluated with univariate and multivariate analyses. The inter-reader and intra-reader reproducibility of the measurements and receiver operating characteristic curve analysis were also performed. Results Placental thickness was significantly higher in patients with PAS disorders (3.45 cm) than that in patients without PAS disorders (2.90 cm) (p < 0.05). Multivariate analyses revealed that prior cesarean section, placenta previa, and placental thickness > 4 cm were independent risk factors for PAS disorders. The inter-reader and intra-reader reproducibility of placental thickness measurement were 0.979 (95% CI 0.960–0.989) and 0.981 (95% CI 0.9640–0.990), respectively. Conclusion The reproducibility of the measurement made from MRI images was high between two radiologists. Patients with PAS disorders had increased placental thickness. Placental thickness > 4 cm correlated with PAS disorders.