AGAiwen Guo

Aiwen Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aiwen Guo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Correlation of placental thickness and placenta percreta in patients with placenta previa: findings from MRI

    by Tao Lu, Yishuang Wang, Aiwen Guo, Yan Deng, Chengqian Wu, Xiangqi Li, Siyun Liu

    Introduction This study aimed to identify if placental thickness measured from MRI images correlated with placenta percreta in patients with placenta previa. Methods Placental thickness was retrospectively measured in 161 patients from July 2018 to August 2020. The measurements were performed at the thickest part of the placenta in the lower uterine segment on the mid-sagittal plane MR images by two independent radiologists. Intraoperative and pathologic findings were the standard of reference. Univariate and multivariate analyses were performed to identify the relationship between clinical features, placental thickness, and placenta percreta. The predictive ability of placental thickness was demonstrated using receiver operating characteristic curve analysis. Results Placental thickness in patients with placenta percreta was significantly higher than in patients with placenta increta, placenta accreta, and normal placentas (p < 0.05). Multivariate analysis revealed that placental thickness was the only independent risk factor for placenta percreta. The cutoff value of placental thickness was 4.35 cm for differentiating placenta percreta in patients with placenta previa. Discussion Patients with placenta percreta had the highest placental thickness. Placental thickness was correlated with placenta percreta.


  • Open Access

    Monoexponential, biexponential and diffusion kurtosis MR imaging models: quantitative biomarkers in the diagnosis of placenta accreta spectrum disorders

    by Tao Lu, Yishuang Wang, Aiwen Guo, Wei Cui, Yazheng Chen, Shaoyu Wang, Guotai Wang

    Background: To investigate the diagnostic value of monoexponential, biexponential, and diffusion kurtosis MR imaging (MRI) in differentiating placenta accreta spectrum (PAS) disorders. Methods: A total of 65 patients with PAS disorders and 27 patients with normal placentas undergoing conventional DWI, IVIM, and DKI were retrospectively reviewed. The mean, minimum, and maximum parameters including the apparent diffusion coefficient (ADC) and exponential ADC (eADC) from standard DWI, diffusion kurtosis (MK), and mean diffusion coefficient (MD) from DKI and pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) from IVIM were measured from the volumetric analysis and compared between patients with PAS disorders and patients with normal placentas. Univariate and multivariated logistic regression analyses were used to evaluate the value of the above parameters for differentiating PAS disorders. Receiver operating characteristics (ROC) curve analyses were used to evaluate the diagnostic efficiency of different diffusion parameters for predicting PAS disorders. Results: Multivariate analysis demonstrated that only D mean and D max differed significantly among all the studied parameters for differentiating PAS disorders when comparisons between accreta lesions in patients with PAS (AP) and whole placentas in patients with normal placentas (WP-normal) were performed (all p < 0.05). For discriminating PAS disorders, a combined use of these two parameters yielded an AUC of 0.93 with sensitivity, specificity, and accuracy of 83.08, 88.89, and 83.70%, respectively. Conclusion: The diagnostic performance of the parameters from accreta lesions was better than that of the whole placenta. D mean and D max were associated with PAS disorders.


  • Correlation of placental thickness and PAS disorders: findings from MRI

    by Tao Lu, Yishuang Wang, Aiwen Guo, Yan Deng, Chengqian Wu, Xiangqi Li, Siyun Liu

    Objective To identify if placental thickness measured from MRI images correlates with placenta accreta spectrum (PAS) disorders. Methods Placental thickness of 245 patients was retrospectively measured from October 2016 to March 2020. The measurement was made at the thickest portion of the placenta on the mid-sagittal plane of the placenta from MRI by two independent radiologists. Surgical report and pathology of the delivered placenta were used as a reference standard. Association between clinical features, placental thickness, and PAS disorders was evaluated with univariate and multivariate analyses. The inter-reader and intra-reader reproducibility of the measurements and receiver operating characteristic curve analysis were also performed. Results Placental thickness was significantly higher in patients with PAS disorders (3.45 cm) than that in patients without PAS disorders (2.90 cm) (p < 0.05). Multivariate analyses revealed that prior cesarean section, placenta previa, and placental thickness > 4 cm were independent risk factors for PAS disorders. The inter-reader and intra-reader reproducibility of placental thickness measurement were 0.979 (95% CI 0.960–0.989) and 0.981 (95% CI 0.9640–0.990), respectively. Conclusion The reproducibility of the measurement made from MRI images was high between two radiologists. Patients with PAS disorders had increased placental thickness. Placental thickness > 4 cm correlated with PAS disorders.