MHMoustafa Abdel Hafiz

Moustafa Abdel Hafiz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Moustafa Abdel Hafiz has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and metrological characterization of a high-performance Cs cell atomic clock based on coherent population trapping

    by Moustafa Abdel Hafiz

    Développement et caractérisation métrologique d'une horloge atomique à cellule de Cs à piégeage cohérent de population de haute performance: Ce travail de thèse, effectué dans le cadre du projet européen MClocks (http://www.inrim.it/mclocks), reporte le développement et la caractérisation métrologique d’une horloge atomique à cellule de césium de haute performance basée sur le phénomène de piégeage cohérent de population (CPT). Cette horloge exploite un schéma de pompage CPT optimisé nommé push-pull optical pumping (PPOP), permettant la détection de résonances CPT à fort contraste sur la transition d’horloge 0-0. Une caractérisation détaillée des différents éléments de l’horloge est reportée. L’horloge fut exploitée en mode continu (CW) et en mode impulsionnel de type Ramsey. Dans les deux modes de fonctionnement, l’horloge démontre une stabilité relative de fréquence de l’ordre de 2 10−13 τ−1/2 jusque 100 s d’intégration, principalement limitée par des effets de puissance laser. Cette horloge atomique, parmi les meilleures horloges à cellule développées à travers le monde, pourrait trouver des applications pour les systèmes de télécommunications, d’instrumentation, de défense ou navigation par satellite.Cette thèse reporte aussi une technique originale de stabilisation de fréquence laser par spectroscopie sub-Dopplerbi-fréquence en cellule. La plateforme constituée par l’horloge a été utilisée pour mener des tests de physique plus amont incluant la caractérisation par spectroscopie CPT d’une cellule de césium avec un revêtement anti-relaxant OTS (octadecyltrichlorosilane) ou la caractérisation de microcellules à vapeur de césium avec gaz tampon développées à FEMTO-ST pour des horloges atomiques miniatures.

  • Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

    by Juliette Breurec, Moustafa Abdel Hafiz, Claudio E. Calosso, Oriane Lelièvre, Rodolphe Boudot

    We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.


  • Open Access

    On the reduction of gas permeation through the glass windows of micromachined vapor cells using Al2O3 coatings

    by C. Carlé, A. Mursa, P. Karvinen, S. Keshavarzi, M. Abdel Hafiz, V. Maurice, R. Boudot, N. Passilly

    Stability and precision of atomic devices are closely tied to the quality and stability of the internal atmosphere of the atomic vapor cells on which they rely. Such an atmosphere can be stabilized by building the cell with low permeation materials such as sapphire or aluminosilicate glass in microfabricated devices. Recently, we have shown that permeation barriers made of Al2O3 thin-film coatings deposited on standard borosilicate glass could be an alternative for buffer gas pressure stabilization. In this study, we, hence, investigate how helium permeation is influenced by the thickness, ranging from 5 to 40 nm, of such Al2O3 thin films coated by atomic layer deposition. Permeation rates are derived from long-term measurements of the pressure-shifted transition frequency of a coherent population trapping (CPT) atomic clock. From thicknesses of 20 nm onward, a significant enhancement of the cell hermeticity is experienced, corresponding to two orders of magnitude lower helium permeation rate. In addition, we test cesium vapor cells filled with neon as a buffer gas and whose windows are coated with 20 nm of Al2O3. As for helium, the permeation rate of neon is significantly reduced, thanks to alumina coatings, leading to a fractional frequency stability of 4×10−12 at 1 day when the cell is used in a CPT clock. These features outperform the typical performances of uncoated Cs–Ne borosilicate cells and highlight the significance of Al2O3 coatings for buffer gas pressure stabilization.


  • Operation of a Ramsey-CPT microcell atomic clock with driving current-based power modulation of a VCSEL

    by C. M. Rivera-Aguilar, M. Callejo, A. Mursa, C. Carlé, R. Vicarini, M. Abdel Hafiz, J.-M. Friedt, N. Passilly, R. Boudot

    We report on the operation of a coherent population trapping (CPT) microcell atomic clock using a pulsed Ramsey-like interrogation. The Ramsey-CPT sequence, defined by two-step optical pulses separated by a free-evolution dark time, is produced by switching on and off the output power of a low-power vertical-cavity surface-emitting laser, through direct modulation of its driving current. High-contrast and narrow Ramsey-CPT fringes are detected without the use of any external optical modulator stage. We demonstrate closed-loop operation of the clock based on high-speed digital signal processing implemented in a field programmable gate array board. The clock's short-term fractional frequency stability is 1.3 × 10−10τ−1/2 until 2000 s. A power light-shift coefficient of 8 × 10−11/μW, in relative value, is obtained for a dark time of 150 μs. This value is about ten times lower than in the continuous regime. These results show the feasibility of fully integrated atomic clocks based on Ramsey spectroscopy, which could provide enhanced long-term stability.


  • Open Access

    Reduction of helium permeation in microfabricated cells using aluminosilicate glass substrates and Al2O3 coatings

    by C. Carlé, S. Keshavarzi, A. Mursa, P. Karvinen, R. Chutani, S. Bargiel, S. Queste, R. Vicarini, P. Abbé, M. Abdel Hafiz, et al.

    The stability and accuracy of atomic devices can be degraded by the evolution of their cell inner atmosphere. Hence, the undesired entrance or leakage of background or buffer gas, respectively, that can permeate through the cell walls, should be slowed down. In this work, we investigate helium permeation in microfabricated alkali vapor cells filled with He and whose windows are made of borosilicate glass (BSG) or aluminosilicate glass (ASG). The permeation is then derived from routine measurements of the pressure-shifted hyperfine transition frequency of an atomic clock. We first confirm that ASG reduces the He permeation rate by more than two orders of magnitude, in comparison to BSG. In addition, we demonstrate that Al2O3 thin-film coatings, known to avoid alkali consumption in vapor cells, can also significantly reduce He permeation. The permeation through BSG is thereby reduced by a factor up to 130, whereas the one through ASG is decreased by a factor up to 5.0 compared to uncoated substrates. These results may contribute to the development of miniaturized atomic clocks and sensors with improved long-term stability or sensitivity.


  • Open Access

    Heating rate measurement and characterization of a prototype surface-electrode trap for optical frequency metrology

    by Thomas Lauprêtre, Bachir Achi, Lucas Groult, Yann Kersalé, Marion Delehaye, Moustafa Abdel Hafiz, Clément Lacroûte

    We present the characterization of a prototype surface-electrode (SE) trap as a first step towards the realization of a compact, single-ion optical clock based on Yb$^+$. The use of a SE trap will be a key factor to benefit from clean-room fabrication techniques and technological advances made in the field of quantum information processing. We succesfully demonstrated trapping at a 500 $\mu$m electrodes distance and characterized our trap in terms of lifetime and heating rate. This is to our knowledge the highest distance achieved for heating rates measurements in SE traps. This simple 5-wire design realized with simple materials yields a heating rate of $\mathbf{8\times 10^3}$ phonons/s. We provide an analysis of the performances of this prototype trap for optical frequency metrology.

  • Light-shift mitigation in a microcell-based atomic clock with symmetric auto-balanced Ramsey spectroscopy

    by M. Abdel Hafiz, C. Carlé, N. Passilly, J. M. Danet, C. E. Calosso, R. Boudot

    The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.


  • All-optical microwave feedback oscillator with atomic cell resonator

    by R. Boudot, M. Abdel Hafiz, M. Petersen, C. E. Calosso, E. Rubiola

    We report the demonstration of an all-optical self-sustained cell-based microwave feedback oscillator. In this scheme, a microwave resonance, optically induced in a buffer-gas filled vapor cell resonator through coherent population trapping (CPT), is detected by a fast photodiode, amplified, and used to drive back, through a frequency divider, a Mach–Zehnder electro-optic modulator in a sustaining loop configuration. The total gain and phase of the system was measured in an open-loop configuration with a network analyzer. In good agreement with values predicted by the Leeson effect, the CPT feedback oscillator demonstrates an absolute phase noise of −24 dB rad2/Hz at 1 Hz offset frequency, compatible with a fractional frequency stability of 8 × 10−12 at 1 s, and a phase noise floor of −112 dB rad2/Hz, limited by the low microwave power available at the photodiode output. The amplitude noise of the oscillator shows a comparable noise floor and, for offset frequencies lower than 200 Hz, a 1/f dependence, due to the presence of the frequency divider in the loop.