CCClaudio Eligio Calosso

Claudio Eligio Calosso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claudio Eligio Calosso has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Frequency Shifts in a Coherent Population Trapping Cs Vapor Cell Atomic Clock

    by Juliette Breurec, Moustafa Abdel Hafiz, Claudio E. Calosso, Oriane Lelièvre, Rodolphe Boudot

    We report on measurements of frequency shifts in a microwave cesium vapor cell atomic clock based on coherent population trapping (CPT). The dependence of the clock frequency on numerous experimental parameters, such as the laser power, the laser frequency, the microwave power, the cell temperature, the static magnetic field, but also the temperature of some key components, or the translation and rotation of critical wave plates and optical elements, is investigated. The stability budget of the clock frequency at one day is reported and discussed. This study constitutes a solid database for the future demonstration of a CPT-based cell clock with enhanced mid- and long-term stability performances.


  • Open Access

    Laser-frequency stabilization using light shift in compact atomic clocks

    by Claudio E. Calosso, Michele Gozzelino, Filippo Levi, Salvatore Micalizio

    This paper describes the light-shift laser-lock (LSLL) technique, an alternative method intended for laser-based compact atomic clocks. The technique greatly simplifies the laser setup by stabilizing the pumping-laser frequency to the same atoms involved in the clock operation, without the need of an external reference. By alternating two clock sequences, the method estimates and cancels out a controlled amount of induced light shift, acting on the laser frequency. The LSLL technique is compatible with state-of-the-art three-level clocks and was demonstrated with field-programmable-gate-array-based electronics on a pulsed-optically-pumped vapor-cell clock developed at INRIM. The results have shown that the LSLL technique operates robustly, having a capture range of gigahertz without significantly compromising clock stability. In our tests, the clock exhibited a white frequency noise of 3.2×10−13τ−1/2 for averaging times τ up to 4000 s, reaching a floor below 1×10−14 up to 100 000 s. This level of performance meets the requirements of future global navigation satellite systems on-board clocks, adding the benefits of a reduced clock footprint, as well as increased reliability and robustness.


  • Open Access

    A cryogenic sapphire resonator oscillator with 10−16 mid-term fractional frequency stability

    by C. Fluhr, B. Dubois, C. E. Calosso, F. Vernotte, E. Rubiola, V. Giordano

    We report in this Letter the outstanding frequency stability performance of an autonomous cryogenic sapphire oscillator (CSO) presenting a flicker frequency noise floor below 2×10−16 near 1000 s of integration time and a long-term Allan deviation limited by a random walk process of ∼1×10−18τ. The frequency stability qualification at this level called for the implementation of sophisticated instrumentation associated with ultra-stable frequency references. This result is technologically sound as it demonstrates the potentiality of the CSO technology. From the physical point of view, it sets an upper limit to the ultimate noise floor of the cryogenic microwave resonator that is competitive to that of the ultra-stable optical Fabry–Pérot cavities.


  • Open Access

    The Digital Revolution, also for Time Scales

    by Claudio E. Calosso

    This work focuses on the generation of a composite clock for time scales and shows the advantages of a more recent digital approach with respect to a traditional analog one. A digital approach directly processes the information contained into the clock sinusoids, instead of the sinusoids themselves and leads to significant advantages in terms of reliability, performance, complexity, flexibility, size, power consumption and cost. A practical example based on a new digital instrument is provided to show how it is possible to combine state-of-the-art clocks from the Oscillator Imp platform at FEMTO-ST and FEMTO Engineering (Besançon, France).

  • Frequency Noise Characterization of Diode Lasers for Vapor-Cell Clock Applications

    by Gaspare Antona, Michele Gozzelino, Salvatore Micalizio, Claudio E. Calosso, Giovanni A. Costanzo, Filippo Levi

    The knowledge of the frequency noise spectrum of a diode laser is of interest in several high-resolution experiments. Specifically, in laser-pumped vapor cell clocks, it is well established that the laser frequency noise plays a role in affecting clock performances. It is then relevant to characterize the frequency noise of a diode laser since such measurements are rarely found in the literature and hardly ever provided by vendors. In this paper, we describe a technique based on a frequency-to-voltage converter that transforms the laser frequency fluctuations into voltage fluctuations. In this way, it is possible to characterize the laser frequency noise power spectral density in a wide range of Fourier frequencies, as required in cell clock applications.


  • Light-shift mitigation in a microcell-based atomic clock with symmetric auto-balanced Ramsey spectroscopy

    by M. Abdel Hafiz, C. Carlé, N. Passilly, J. M. Danet, C. E. Calosso, R. Boudot

    The mid-term fractional frequency stability of miniaturized atomic clocks can be limited by light-shift effects. In this Letter, we demonstrate the implementation of a symmetric auto-balanced Ramsey (SABR) interrogation sequence in a microcell-based atomic clock based on coherent population trapping. Using this advanced protocol, the sensitivity of the clock frequency to laser power, microwave power, and laser frequency variations is reduced, at least by one order of magnitude, in comparison with continuous-wave or Ramsey interrogation schemes. Light-shift mitigation obtained with the SABR sequence benefits greatly to the clock Allan deviation for integration times between 102 and 105 s. These results demonstrate that such interrogation techniques are of interest to enhance the timekeeping performance of chip-scale atomic clocks.


  • All-optical microwave feedback oscillator with atomic cell resonator

    by R. Boudot, M. Abdel Hafiz, M. Petersen, C. E. Calosso, E. Rubiola

    We report the demonstration of an all-optical self-sustained cell-based microwave feedback oscillator. In this scheme, a microwave resonance, optically induced in a buffer-gas filled vapor cell resonator through coherent population trapping (CPT), is detected by a fast photodiode, amplified, and used to drive back, through a frequency divider, a Mach–Zehnder electro-optic modulator in a sustaining loop configuration. The total gain and phase of the system was measured in an open-loop configuration with a network analyzer. In good agreement with values predicted by the Leeson effect, the CPT feedback oscillator demonstrates an absolute phase noise of −24 dB rad2/Hz at 1 Hz offset frequency, compatible with a fractional frequency stability of 8 × 10−12 at 1 s, and a phase noise floor of −112 dB rad2/Hz, limited by the low microwave power available at the photodiode output. The amplitude noise of the oscillator shows a comparable noise floor and, for offset frequencies lower than 200 Hz, a 1/f dependence, due to the presence of the frequency divider in the loop.


  • Open Access

    Phase-Noise and Amplitude-Noise Measurement of DACs and DDSs

    by Claudio E. Calosso, A. Carolina Cardenas Olaya, Enrico Rubiola

    This article proposes a method for the measurement of Phase Noise (PN, or PM noise) and Amplitude Noise (AN, or AM noise) of Digital-to-Analog Converters (DAC) and Direct Digital Synthesizers (DDS) based on modulation-index amplification. The carrier is first reduced by a controlled amount (30-40 dB) by adding a reference signal of nearly equal amplitude and opposite in phase. Then, residual carrier and noise sidebands are amplified and sent to a conventional PN analyzer. The main virtues of our method are: (i) the noise specs of the PN analyzer are relaxed by a factor equal to the carrier suppression ratio; and, (ii) the capability to measure the AN using a PN analyzer, with no need for the analyzer to feature AN measurement. An obvious variant enables AN and PN measurements using an AN analyzer with no PN measurement capability. Such instrument is extremely simple and easy to implement with a power-detector diode followed by a FFT analyzer. Unlike the classical bridge (interferometric) method, there is no need for external line stretcher and variable attenuators because phase and amplitude control is implemented in the device under test. In one case (AD9144), we could measure the noise over 10 decades of frequency. The flicker noise matches the exact 1/f law with a maximum discrepancy of ±1 dB over 7.5 decades. Thanks to simplicity, reliability, and low background noise, this method has the potential to become the standard method for the AN and PN measurement of DACs and DDSs.


  • Open Access

    A scalable hardware and software control apparatus for experiments with hybrid quantum systems

    by Elia Perego, Marco Pomponio, Amelia Detti, Lucia Duca, Carlo Sias, Claudio E. Calosso

    Modern experiments with fundamental quantum systems - like ultracold atoms, trapped ions, single photons - are managed by a control system formed by a number of input/output electronic channels governed by a computer. In hybrid quantum systems, where two or more quantum systems are combined and made to interact, establishing an efficient control system is particularly challenging due to the higher complexity, especially when each single quantum system is characterized by a different timescale. Here we present a new control apparatus specifically designed to efficiently manage hybrid quantum systems. The apparatus is formed by a network of fast communicating Field Programmable Gate Arrays (FPGAs), the action of which is administrated by a software. Both hardware and software share the same tree-like structure, which ensures a full scalability of the control apparatus. In the hardware, a master board acts on a number of slave boards, each of which is equipped with an FPGA that locally drives analog and digital input/output channels and radiofrequency (RF) outputs up to 400 MHz. The software is designed to be a general platform for managing both commercial and home-made instruments in a user-friendly and intuitive Graphical User Interface (GUI). The architecture ensures that complex control protocols can be carried out, such as performing of concurrent commands loops by acting on different channels, the generation of multi-variable error functions and the implementation of self-optimization procedures. Although designed for managing experiments with hybrid quantum systems, in particular with atom-ion mixtures, this control apparatus can in principle be used in any experiment in atomic, molecular, and optical physics.

  • A scalable hardware and software control apparatus for experiments with hybrid quantum systems

    by Elia Perego, Marco Pomponio, Amelia Detti, Lucia Duca, Carlo Sias, Claudio E. Calosso

    Modern experiments with fundamental quantum systems — like ultracold atoms, trapped ions, and single photons — are managed by a control system formed by a number of input/output electronic channels governed by a computer. In hybrid quantum systems, where two or more quantum systems are combined and made to interact, establishing an efficient control system is particularly challenging due to the higher complexity, especially when each single quantum system is characterized by a different time scale. Here we present a new control apparatus specifically designed to efficiently manage hybrid quantum systems. The apparatus is formed by a network of fast communicating Field Programmable Gate Arrays (FPGAs), the action of which is administrated by a software. Both hardware and software share the same tree-like structure, which ensures a full scalability of the control apparatus. In the hardware, a master board acts on a number of slave boards, each of which is equipped with an FPGA that locally drives analog and digital input/output channels and radiofrequency outputs up to 400 MHz. The software is designed to be a general platform for managing both commercial and home-made instruments in a user-friendly and intuitive graphical user interface. The architecture ensures that complex control protocols can be carried out, such as performing of concurrent commands loops by acting on different channels, the generation of multi-variable error functions, and the implementation of self-optimization procedures. Although designed for managing experiments with hybrid quantum systems, in particular with atom-ion mixtures, this control apparatus can in principle be used in any experiment in atomic, molecular, and optical physics.