Xuze Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xuze Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Jingang Li
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
3 shared publicationsXiangqian Tong
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
2 shared publications- Jian Zhang
Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
1 shared publication - Jingang Li
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
1 shared publication Liyong Wei
State Grid Tianjin Electric Power Company (China)
1 shared publication- Qiang Wang
Key Laboratory of Electromagnetic Processing of Materials (Ministry of Education), Northeastern University, Shenyang 110819, China
1 shared publication
Latest Publications
- 23 January 2026
- Published by Springer Nature
- p. 729-736
Voltage Doubling and Current Doubling Electric Vehicle Wireless Power Transmission System Based on Hybrid Compensation Network
- 23 January 2026
- Published by Springer Nature
- p. 729-736
Voltage Doubling and Current Doubling Electric Vehicle Wireless Power Transmission System Based on Hybrid Compensation Network
- 25 September 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12788, 376-381
A quantitative assessment method for electric vehicle acceptance capacity considering orderly charging
In this paper, by studying the sensitivity of reliability indicators to the scale of electric vehicles, a new perspective can be found to quantitatively assess the electric vehicle acceptance capacity. Firstly, an EV charging load model and an optimization strategy for orderly peak and valley tariff periods are established; secondly, indicators such as maximum acceptance and reliability sensitivity are proposed to quantitatively characterize the system's ability to withstand EV access; finally, a quantitative assessment method for EV acceptance taking into account orderly charging is proposed in combination with traditional reliability assessment methods, and a significant sampling method is used to improve the sampling simulation efficiency. The quantitative assessment method and metrics can be extended and applied to the actual grid regulation of EV access scale to ensure the safety and reliability of the system.
- 25 September 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12788, 376-381
A quantitative assessment method for electric vehicle acceptance capacity considering orderly charging
In this paper, by studying the sensitivity of reliability indicators to the scale of electric vehicles, a new perspective can be found to quantitatively assess the electric vehicle acceptance capacity. Firstly, an EV charging load model and an optimization strategy for orderly peak and valley tariff periods are established; secondly, indicators such as maximum acceptance and reliability sensitivity are proposed to quantitatively characterize the system's ability to withstand EV access; finally, a quantitative assessment method for EV acceptance taking into account orderly charging is proposed in combination with traditional reliability assessment methods, and a significant sampling method is used to improve the sampling simulation efficiency. The quantitative assessment method and metrics can be extended and applied to the actual grid regulation of EV access scale to ensure the safety and reliability of the system.
- 14 September 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (6) , 4571-4579
A composite network model for load-independent output and near unit power factor in WPT system
- 14 September 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (6) , 4571-4579
A composite network model for load-independent output and near unit power factor in WPT system
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 1301-1313
Research and Design of Misalignment-Tolerant LCC–LCC Compensated IPT System With Constant-Current and Constant-Voltage Output
It is well known that loads of inductive power transfer systems are often energy storage devices. The major benefit of an LCC–LCC compensation topology is that without the additional compensation elements and control methods, the load-independent constant current (CC) and constant voltage (CV) outputs, required by energy storage load, can be achieved at different resonant frequencies. However, the misalignment between two coils at the transmitting and receiving sides is inevitable and can lead to the variation of the resonant frequency in CC or CV output. Therefore, a unique design approach to the LCC–LCC compensation topology is proposed in this article. With the presented method, the resonant frequency, at which load-independent output characteristics can be also implemented, is constant and unaffected by the coupling coefficient, whether in CC mode or CV mode. Furthermore, the transmission gain, which is only impacted by the coupling coefficient, can be conveniently modified by the conventional phase shift control in two modes. Finally, a 120-W prototype is designed to verify the validity of the theoretical analysis. The output current and output voltage fluctuate by only 2.4% and 1.0% in the coupling coefficient range from 0.23 to 0.3 and the large load range, according to experimental results.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 1301-1313
Research and Design of Misalignment-Tolerant LCC–LCC Compensated IPT System With Constant-Current and Constant-Voltage Output
It is well known that loads of inductive power transfer systems are often energy storage devices. The major benefit of an LCC–LCC compensation topology is that without the additional compensation elements and control methods, the load-independent constant current (CC) and constant voltage (CV) outputs, required by energy storage load, can be achieved at different resonant frequencies. However, the misalignment between two coils at the transmitting and receiving sides is inevitable and can lead to the variation of the resonant frequency in CC or CV output. Therefore, a unique design approach to the LCC–LCC compensation topology is proposed in this article. With the presented method, the resonant frequency, at which load-independent output characteristics can be also implemented, is constant and unaffected by the coupling coefficient, whether in CC mode or CV mode. Furthermore, the transmission gain, which is only impacted by the coupling coefficient, can be conveniently modified by the conventional phase shift control in two modes. Finally, a 120-W prototype is designed to verify the validity of the theoretical analysis. The output current and output voltage fluctuate by only 2.4% and 1.0% in the coupling coefficient range from 0.23 to 0.3 and the large load range, according to experimental results.
- 29 January 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2197-2204
A multi-objective-based parametric design method for WPT systems with double-sided LCC compensation network
- 29 January 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2197-2204
A multi-objective-based parametric design method for WPT systems with double-sided LCC compensation network