Jingang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingang Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xiangqian Tong
School of Electrical Engineering, Xi’an University of Technology, Xi’an 710048, China
6 shared publications - Zhaowei Gong
School of Electronic Information Engineering Xi'an Technological University Xi'an China
4 shared publications Xuze Zhang
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
3 shared publicationsXiangqian Tong
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
2 shared publications- Ningchao Zhang
College of Electronics and Information Engineering, Xi'an Technological University, Xi'an 710021, China
1 shared publication - Xuze Zhang
School of Electrical Engineering, Xi’an University of Technology, Xi’an, China
1 shared publication
Latest Publications
- 23 January 2026
- Published by Springer Nature
- p. 729-736
Voltage Doubling and Current Doubling Electric Vehicle Wireless Power Transmission System Based on Hybrid Compensation Network
- 23 January 2026
- Published by Springer Nature
- p. 729-736
Voltage Doubling and Current Doubling Electric Vehicle Wireless Power Transmission System Based on Hybrid Compensation Network
- Open Access
- 10 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (8) , 1536
A Novel Optimization Method of the DS-LCC Compensation Topology to Reduce the Sensitivity of the Load-Independent Constant Current Output Characteristics to the Component Parametric Deviation
For the double-sided inductor–capacitor–capacitor (DS-LCC) compensation topology, the parametric deviation of compensation elements results in the mismatch between the resonant frequency and operating frequency. Furthermore, this mismatch leads to the loss of the load-independent constant output characteristics. Therefore, an innovative design approach based on the reduction in the capacitance ratio is proposed to attain the load-independent constant current under the parametric deviation. With the presented method, simply by reducing the compensation capacitor ratio, the load-independent constant current output characteristics can be preserved, and fluctuations in the transmission gain caused by the parametric deviation are minimized. This implies that when the constant transmission gain is achieved by the frequency modulation (FM) control, the required FM range can be reduced. Finally, from the experimental results, in the load range of 3 Ω to 33 Ω, compared to the high capacitance ratio, the load-independent constant current characteristics can be maintained at the low capacitance ratio. In addition, without parametric deviation, the transmission efficiencies at different capacitance ratios are basically the same at 93.5% and 94.2%, respectively. However, the transmission efficiencies under different parametric deviations at the low capacitance ratio are 87.4% and 84.9%, but only 73.9% and 68.2% at the high capacitance ratio.
- 10 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (8) , 1536
Open AccessA Novel Optimization Method of the DS-LCC Compensation Topology to Reduce the Sensitivity of the Load-Independent Constant Current Output Characteristics to the Component Parametric Deviation
For the double-sided inductor–capacitor–capacitor (DS-LCC) compensation topology, the parametric deviation of compensation elements results in the mismatch between the resonant frequency and operating frequency. Furthermore, this mismatch leads to the loss of the load-independent constant output characteristics. Therefore, an innovative design approach based on the reduction in the capacitance ratio is proposed to attain the load-independent constant current under the parametric deviation. With the presented method, simply by reducing the compensation capacitor ratio, the load-independent constant current output characteristics can be preserved, and fluctuations in the transmission gain caused by the parametric deviation are minimized. This implies that when the constant transmission gain is achieved by the frequency modulation (FM) control, the required FM range can be reduced. Finally, from the experimental results, in the load range of 3 Ω to 33 Ω, compared to the high capacitance ratio, the load-independent constant current characteristics can be maintained at the low capacitance ratio. In addition, without parametric deviation, the transmission efficiencies at different capacitance ratios are basically the same at 93.5% and 94.2%, respectively. However, the transmission efficiencies under different parametric deviations at the low capacitance ratio are 87.4% and 84.9%, but only 73.9% and 68.2% at the high capacitance ratio.
- Open Access
- 19 August 2024
- Published by Springer Nature in Research Square
A Novel Hybrid Control Strategy to Implement Constant Current Output with ZVS for the double-side LCC Compensation Topology
To implement stable output current and zero-voltage switching(ZVS) with the minimum reactive current over a range of load and coupling coefficient for the double-sided LCC(DS-LCC) compensated inductive power transfer(IPT) system, a hybrid phase shift control and switched controllable capacitor(SCC) strategy is proposed in this paper. In the proposed control strategy, the output current can be regulated through the phase shift modulation, and the reactive current can be lowered by SCC. Most importantly, for the simplification and enhancement of the control system, the function between the phase shift angle and the SCC associated control angle is established, which means that two control variables can be regulated through a single close loop. Further, with the proposed hybrid control strategy, ZVS at the minimum reactive current can be realized over the range of the load and coupling coefficient, which means that efficiency at the low power can be enhanced. In order to validate the rightness and practicality of the proposed hybrid control strategy, a 120 W experimental prototype of the proposed DS-LCC compensated IPT system is constructed. The stable output current and ZVS with the minimum reactive current can be achieved over the coupling coefficient between 0.2 and 0.3, and the DC-DC maximum efficiency is 94.5%, proven by experimental results.
- 19 August 2024
- Published by Springer Nature in Research Square
Open AccessA Novel Hybrid Control Strategy to Implement Constant Current Output with ZVS for the double-side LCC Compensation Topology
To implement stable output current and zero-voltage switching(ZVS) with the minimum reactive current over a range of load and coupling coefficient for the double-sided LCC(DS-LCC) compensated inductive power transfer(IPT) system, a hybrid phase shift control and switched controllable capacitor(SCC) strategy is proposed in this paper. In the proposed control strategy, the output current can be regulated through the phase shift modulation, and the reactive current can be lowered by SCC. Most importantly, for the simplification and enhancement of the control system, the function between the phase shift angle and the SCC associated control angle is established, which means that two control variables can be regulated through a single close loop. Further, with the proposed hybrid control strategy, ZVS at the minimum reactive current can be realized over the range of the load and coupling coefficient, which means that efficiency at the low power can be enhanced. In order to validate the rightness and practicality of the proposed hybrid control strategy, a 120 W experimental prototype of the proposed DS-LCC compensated IPT system is constructed. The stable output current and ZVS with the minimum reactive current can be achieved over the coupling coefficient between 0.2 and 0.3, and the DC-DC maximum efficiency is 94.5%, proven by experimental results.
- 23 March 2023
- Published by Springer Nature
- p. 1-7
Quadrature Six-Coils Wireless Charging with High Misalignment Tolerance and Constant Voltage Output
- 23 March 2023
- Published by Springer Nature
- p. 1-7
Quadrature Six-Coils Wireless Charging with High Misalignment Tolerance and Constant Voltage Output
- Open Access
- 26 February 2023
- Published by MDPI AG in Electronics
- Vol. 12 (5) , 1138
A Misalignment-Insensitive Hybrid IPT System with Constant Current Output Based on Parameter Optimization
High misalignment-insensitive capacity is of great importance for inductive power transfer (IPT) systems. A hybrid topology based on a parameter optimization design method is presented to obtain constant current output regardless of the coupling and load. DDQ coils are employed to protect against system key parameter changes, and a particle swarm optimization (PSO) method has been presented to achieve a nearly constant current output without using complex control schemes. A hybrid IPT system using DDQ coils has been built. The experimental results verify that the current fluctuation is within 5% when the load varies from 5 Ω to 10 Ω within 50% misalignment of the coupling pads. Moreover, the maximum system DC–DC efficiency is up to 91%.
- 26 February 2023
- Published by MDPI AG in Electronics
- Vol. 12 (5) , 1138
Open AccessA Misalignment-Insensitive Hybrid IPT System with Constant Current Output Based on Parameter Optimization
High misalignment-insensitive capacity is of great importance for inductive power transfer (IPT) systems. A hybrid topology based on a parameter optimization design method is presented to obtain constant current output regardless of the coupling and load. DDQ coils are employed to protect against system key parameter changes, and a particle swarm optimization (PSO) method has been presented to achieve a nearly constant current output without using complex control schemes. A hybrid IPT system using DDQ coils has been built. The experimental results verify that the current fluctuation is within 5% when the load varies from 5 Ω to 10 Ω within 50% misalignment of the coupling pads. Moreover, the maximum system DC–DC efficiency is up to 91%.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 1288-1300
A Unique Design Approach of Double-Sided LCC Compensated IPT System for Misalignment-Tolerant Characteristic
For double-sided LCC compensation topology, it is not easy to maintain the output current and output voltage constant over the variation of coupling coefficient and load. Consequently, in this article, a unique design approach is presented. With the presented method, whether during a constant current output procedure or constant voltage output procedure, the resonant frequency maintains constant and cannot be affected by the coupling coefficient and load condition. In addition, the transmission gain is kept constant in different misalignment by the phase shift modulation. Zero voltage switching with the minimum reactive current can be implemented by the switch-controlled capacitor (SCC) regardless of the coupling coefficient and owing to the constant phasor of the current flowing the SCC, the control system of SCC is greatly simplified. Finally, a 60 W prototype is designed to verify the validity of the theoretical analysis. From the results of the experiment, when the coupling coefficient range is between 0.13 and 0.2, the fluctuation factors of output current and output voltage are only 0.5% and 1.0%, respectively.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 1288-1300
A Unique Design Approach of Double-Sided LCC Compensated IPT System for Misalignment-Tolerant Characteristic
For double-sided LCC compensation topology, it is not easy to maintain the output current and output voltage constant over the variation of coupling coefficient and load. Consequently, in this article, a unique design approach is presented. With the presented method, whether during a constant current output procedure or constant voltage output procedure, the resonant frequency maintains constant and cannot be affected by the coupling coefficient and load condition. In addition, the transmission gain is kept constant in different misalignment by the phase shift modulation. Zero voltage switching with the minimum reactive current can be implemented by the switch-controlled capacitor (SCC) regardless of the coupling coefficient and owing to the constant phasor of the current flowing the SCC, the control system of SCC is greatly simplified. Finally, a 60 W prototype is designed to verify the validity of the theoretical analysis. From the results of the experiment, when the coupling coefficient range is between 0.13 and 0.2, the fluctuation factors of output current and output voltage are only 0.5% and 1.0%, respectively.
- Open Access
- 17 July 2022
- Published by MDPI AG in Electronics
- Vol. 11 (14) , 2228
A Hybrid Inductive Power Transfer System with High Misalignment Tolerance Using Double-DD Quadrature Pads
Inductive power transfer (IPT) has been widely adopted as an efficient and convenient charging manner for both static and in-motion EVs. In this paper, a new hybrid topology is presented to improve the coupling tolerance under pad misalignment. The double inductor–capacitor–capacitor (LCC-LCC) network and series hybrid network combining the LCC-LCC topology and series-series (SS) topology are connected in parallel to provide better tolerance against self- and mutual inductance changes, particularly with a large Z-axis transmission distance. A double-DD quadrature pad (DD2Q) consists of a Q pad, and double orthogonal DD pads are analyzed in detail, which are employed to decouple the cross-mutual inductance. Moreover, a parametric design method based on the misalignment characteristics of the DD2Q pads is also proposed to maintain relatively constant power output. A 650-W hybrid topology with a fixed operating frequency of 85 kHz was built to verify the system’s feasibility. The size of the DD2Q pads was 280 mm × 280 mm, and the air gap was 100 mm. The results clearly show that the proposed hybrid topology can achieve a fluctuation within 5% in the output current with load varying from 100% full load to 25% light load conditions when the Z-axis transmission distance varies from 80 mm to 150 mm, and the maximum efficiency can reach 91% when the Z-axis transmission distance is 80 mm.
- 17 July 2022
- Published by MDPI AG in Electronics
- Vol. 11 (14) , 2228
Open AccessA Hybrid Inductive Power Transfer System with High Misalignment Tolerance Using Double-DD Quadrature Pads
Inductive power transfer (IPT) has been widely adopted as an efficient and convenient charging manner for both static and in-motion EVs. In this paper, a new hybrid topology is presented to improve the coupling tolerance under pad misalignment. The double inductor–capacitor–capacitor (LCC-LCC) network and series hybrid network combining the LCC-LCC topology and series-series (SS) topology are connected in parallel to provide better tolerance against self- and mutual inductance changes, particularly with a large Z-axis transmission distance. A double-DD quadrature pad (DD2Q) consists of a Q pad, and double orthogonal DD pads are analyzed in detail, which are employed to decouple the cross-mutual inductance. Moreover, a parametric design method based on the misalignment characteristics of the DD2Q pads is also proposed to maintain relatively constant power output. A 650-W hybrid topology with a fixed operating frequency of 85 kHz was built to verify the system’s feasibility. The size of the DD2Q pads was 280 mm × 280 mm, and the air gap was 100 mm. The results clearly show that the proposed hybrid topology can achieve a fluctuation within 5% in the output current with load varying from 100% full load to 25% light load conditions when the Z-axis transmission distance varies from 80 mm to 150 mm, and the maximum efficiency can reach 91% when the Z-axis transmission distance is 80 mm.
- Open Access
Misalignment-Tolerant Series Hybrid with Active Adjustable Constant Current and Constant Voltage Output Wireless Charging System
This paper presents a series hybrid wireless charging system with an active adjustable circuitry offering constant current and constant voltage output characteristics. The series hybrid system consists of the inductor–capacitor–capacitor (LCC) and series-series (SS) networks are used for improving charging pad misalignment tolerance. An active switch is employed to provide an adjustable CC and CV output for different battery charging stages. To demonstrate the performance of the proposed method, a 310 W prototype was built. A systematic optimization in the parameter of the proposed topology to achieve relative constant output was analyzed within a certain range of the designed operating region. The experimental results indicate that the output current fluctuation is less than 5% with load variations, and the output voltage fluctuation is less than 5% with load varying from 19 to 70 Ω, as the pick-up pads misaligned within 50% of the pad outer diameter.
Open AccessMisalignment-Tolerant Series Hybrid with Active Adjustable Constant Current and Constant Voltage Output Wireless Charging System
This paper presents a series hybrid wireless charging system with an active adjustable circuitry offering constant current and constant voltage output characteristics. The series hybrid system consists of the inductor–capacitor–capacitor (LCC) and series-series (SS) networks are used for improving charging pad misalignment tolerance. An active switch is employed to provide an adjustable CC and CV output for different battery charging stages. To demonstrate the performance of the proposed method, a 310 W prototype was built. A systematic optimization in the parameter of the proposed topology to achieve relative constant output was analyzed within a certain range of the designed operating region. The experimental results indicate that the output current fluctuation is less than 5% with load variations, and the output voltage fluctuation is less than 5% with load varying from 19 to 70 Ω, as the pick-up pads misaligned within 50% of the pad outer diameter.