Yong-Seok Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yong-Seok Lee has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Kwi-Dug Yun
Department of Prosthodontics, School of Dentistry, Chonnam National University, Gwangju, Republic of Korea
4 shared publications - Yoo-Na Jung
Department of Prosthodontics, School of Dentistry, Chonnam National University, Gwangju 61186, Republic of Korea
3 shared publications - Dong-Won Jang
Division of Mechanical Systems Engineering, Myongji University, Yongin 17058, Republic of Korea
2 shared publications - Geelsu Hwang
Department of Preventive and Restorative Sciences, School of Dental Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publications - Jinhyoung Park
Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
2 shared publications - Seong-Won Choi
Industry Support Center for Convergence Medical Devices, Chonnam National University Hospital, Gwangju 61469, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 31 October 2025
- Published by MDPI AG in Electronics
- Vol. 14  (21) , 4293
Crack Diagnosis of Surface-Mount Capacitors Using AI Classification Models with Multi-Parameter Impedance Spectra
Surface-mounted devices (SMDs) are essential components that enable the miniaturization and enhanced performance in electronic products, significantly impacting both circuit performance and reliability. In this study, we propose a non-destructive evaluation method for cracks in SMD capacitors using the artificial intelligence of impedance spectra. To achieve this, cracks were induced in 132 specimens through incremental displacement using a shear module of a bond tester. At each crack level, frequency-domain spectra were acquired for 14 parameters using an impedance analyzer. Meaningful changes in parameter patterns corresponding to each crack stage were observed, confirming impedance spectroscopy as an effective tool for crack assessment. Through data augmentation, we generated 87,800 datasets representing various crack stages, which were used to train AI models that output crack stages from input impedance spectra. Based on this dataset, six AI models, ConvNeXt, LSTM, Transformer, Logistic Regression, SVM, and Random Forest, were developed to classify crack severity into nine stages. Model-wise, the Random Forest classifier consistently outperformed the other approaches. When trained with single parameters, it achieved its best performance using the dissipation factor, reaching 98.5% accuracy. Furthermore, when the dissipation factor was combined with any of the remaining impedance parameters, the Random Forest model achieved perfect diagnostic performance (100%) across all combinations, highlighting both its robustness and its suitability for multi-parameter learning. These results provide practical guidance for selecting effective parameters and model architectures for impedance spectrum-based crack diagnostics.
- 31 October 2025
- Published by MDPI AG in Electronics
- Vol. 14  (21) , 4293
Open AccessCrack Diagnosis of Surface-Mount Capacitors Using AI Classification Models with Multi-Parameter Impedance Spectra
Surface-mounted devices (SMDs) are essential components that enable the miniaturization and enhanced performance in electronic products, significantly impacting both circuit performance and reliability. In this study, we propose a non-destructive evaluation method for cracks in SMD capacitors using the artificial intelligence of impedance spectra. To achieve this, cracks were induced in 132 specimens through incremental displacement using a shear module of a bond tester. At each crack level, frequency-domain spectra were acquired for 14 parameters using an impedance analyzer. Meaningful changes in parameter patterns corresponding to each crack stage were observed, confirming impedance spectroscopy as an effective tool for crack assessment. Through data augmentation, we generated 87,800 datasets representing various crack stages, which were used to train AI models that output crack stages from input impedance spectra. Based on this dataset, six AI models, ConvNeXt, LSTM, Transformer, Logistic Regression, SVM, and Random Forest, were developed to classify crack severity into nine stages. Model-wise, the Random Forest classifier consistently outperformed the other approaches. When trained with single parameters, it achieved its best performance using the dissipation factor, reaching 98.5% accuracy. Furthermore, when the dissipation factor was combined with any of the remaining impedance parameters, the Random Forest model achieved perfect diagnostic performance (100%) across all combinations, highlighting both its robustness and its suitability for multi-parameter learning. These results provide practical guidance for selecting effective parameters and model architectures for impedance spectrum-based crack diagnostics.
- Open Access
- 3 September 2025
- Published by MDPI AG in Biomimetics
- Vol. 10  (9) , 583
Micro-CT and Histomorphometric Analysis of Degradability and New Bone Formation of Anodized Mg-Ca System
The surface treatments and various magnesium alloys are applied to improve the fast degradation rate and resulting negative effects of magnesium alloys. This study aimed to assess the effect of anodic oxidation treatment of magnesium–calcium (Mg-Ca) systems by creating artificial bone defects in the tibia of rats. The cylinder magnesium implants were fabricated using a Mg-xCa (x = 0, 1, 5 wt.%) binary alloy. Degradability and new bone formation were observed at two and six weeks using micro-CT. Histomorphometric parameters were evaluated with Goldner’s trichrome staining. The degradation rate decreased depending on the amount of calcium added. The parameters related to bone formation revealed an increasing pattern depending on the addition of calcium, anodic oxidation, and time. The amount of absorbed magnesium to assess degradability of magnesium implants by the histomorphometric analysis revealed a high value in the untreated group at two and six weeks. Bone healing parameters increased depending on the amount of calcium added, anodic oxidation treatment, and region of interest (ROI—0.5 mm, 1.00 mm, 1.5 mm, and 2.0 mm). Biodegradable magnesium systems have the potential to replace bone screws and plates. Combination with calcium combined with anodization surface treatment can improve initial corrosion resistance and promote bone formation.
- 3 September 2025
- Published by MDPI AG in Biomimetics
- Vol. 10  (9) , 583
Open AccessMicro-CT and Histomorphometric Analysis of Degradability and New Bone Formation of Anodized Mg-Ca System
The surface treatments and various magnesium alloys are applied to improve the fast degradation rate and resulting negative effects of magnesium alloys. This study aimed to assess the effect of anodic oxidation treatment of magnesium–calcium (Mg-Ca) systems by creating artificial bone defects in the tibia of rats. The cylinder magnesium implants were fabricated using a Mg-xCa (x = 0, 1, 5 wt.%) binary alloy. Degradability and new bone formation were observed at two and six weeks using micro-CT. Histomorphometric parameters were evaluated with Goldner’s trichrome staining. The degradation rate decreased depending on the amount of calcium added. The parameters related to bone formation revealed an increasing pattern depending on the addition of calcium, anodic oxidation, and time. The amount of absorbed magnesium to assess degradability of magnesium implants by the histomorphometric analysis revealed a high value in the untreated group at two and six weeks. Bone healing parameters increased depending on the amount of calcium added, anodic oxidation treatment, and region of interest (ROI—0.5 mm, 1.00 mm, 1.5 mm, and 2.0 mm). Biodegradable magnesium systems have the potential to replace bone screws and plates. Combination with calcium combined with anodization surface treatment can improve initial corrosion resistance and promote bone formation.
- Open Access
- 19 June 2025
- Published by Frontiers Media SA in Frontiers in Nanotechnology
- Vol. 7, 1634033
Omnidirectionally stretchable, biodegradable mesh electrode with re-entrant structure for spatial-stable functional position on dynamic organs
The electrode, interfacing with soft tissue, is vulnerable to mechanical failure caused by dynamic organ motions such as cardiac activity, respiration, and digestion. Mechanical mismatch can also lead to tissue damage and sensor displacement. However, existing strategies for conformal integration often fall short of preserving mechanical compliance across large-area, multi-electrode arrays. Most internal organs undergo complex, anisotropic volumetric expansion from physiological activity, requiring implanted systems that can withstand multidirectional strains without inducing stress concentration. Conventional elastomers and mesh-structured electrodes typically exhibit a positive Poisson’s ratio, which hinders multidirectional uniform stretching and results in mechanical mismatch at the tissue–electrode interface. This mismatch not only increases local mechanical load but also leads to electrode displacement. In this study, we propose a conformal electrode design that incorporates a re-entrant geometry into a stretchable and biodegradable polyurethane substrate. Mechanical testing confirmed that this geometry enhances stretchability and reduces the effective modulus of the electrode by approximately 64%. Furthermore, the device maintained electrical stability under cyclic deformation and preserved its structural integrity under dynamic, organ-mimicking volumetric expansion. This mechanical and electrical robustness highlights the potential of the proposed design for long-term integration into implantable electrode arrays for physiological monitoring and disease diagnosis on dynamic three-dimensional organ motion.
- 19 June 2025
- Published by Frontiers Media SA in Frontiers in Nanotechnology
- Vol. 7, 1634033
Open AccessOmnidirectionally stretchable, biodegradable mesh electrode with re-entrant structure for spatial-stable functional position on dynamic organs
The electrode, interfacing with soft tissue, is vulnerable to mechanical failure caused by dynamic organ motions such as cardiac activity, respiration, and digestion. Mechanical mismatch can also lead to tissue damage and sensor displacement. However, existing strategies for conformal integration often fall short of preserving mechanical compliance across large-area, multi-electrode arrays. Most internal organs undergo complex, anisotropic volumetric expansion from physiological activity, requiring implanted systems that can withstand multidirectional strains without inducing stress concentration. Conventional elastomers and mesh-structured electrodes typically exhibit a positive Poisson’s ratio, which hinders multidirectional uniform stretching and results in mechanical mismatch at the tissue–electrode interface. This mismatch not only increases local mechanical load but also leads to electrode displacement. In this study, we propose a conformal electrode design that incorporates a re-entrant geometry into a stretchable and biodegradable polyurethane substrate. Mechanical testing confirmed that this geometry enhances stretchability and reduces the effective modulus of the electrode by approximately 64%. Furthermore, the device maintained electrical stability under cyclic deformation and preserved its structural integrity under dynamic, organ-mimicking volumetric expansion. This mechanical and electrical robustness highlights the potential of the proposed design for long-term integration into implantable electrode arrays for physiological monitoring and disease diagnosis on dynamic three-dimensional organ motion.
- Open Access
- 14 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16  (4) , 139
Evaluation of the Characteristics of Digital Light Processing 3D-Printed Magnesium Calcium Phosphate for Bone Regeneration
Recent advancements in three-dimensional (3D) printing technology, particularly digital light processing (DLP) 3D printing, have enabled the customization of bone substitutes with specific shapes that match bone defect sizes and geometries. Magnesium calcium phosphate (MCP) has gained considerable attention due to its strong mechanical properties, degradability, and ability to promote bone regeneration. In this study, we prepared MCP samples with five different molar ratios via DLP 3D printing. We analyzed the physicochemical properties of these five groups, including phase compositions and microstructures, which were examined using X-ray diffraction and scanning electron microscopy, respectively. Additionally, we assessed the effects of MCP on material density and shrinkage. Biaxial flexural strength and degradation rate were evaluated; biological properties were examined through WST-8 analysis and alkaline phosphatase activity assays. Among the tested samples, MCP1/1 exhibited the highest strength. A higher proportion of magnesium phosphate in MCP corresponded to an increased degradation rate. Cell response observations in the WST-8 assay indicated that cell proliferation was better in the MCP1/1 group than in the other groups on days 4 and 7 of culturing. Alkaline phosphatase activity assays demonstrated that MCP1/1 exhibited higher activity than calcium phosphate. Our findings suggest that MCP1/1 can be used effectively in bone-tissue-engineering applications.
- 14 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16  (4) , 139
Open AccessEvaluation of the Characteristics of Digital Light Processing 3D-Printed Magnesium Calcium Phosphate for Bone Regeneration
Recent advancements in three-dimensional (3D) printing technology, particularly digital light processing (DLP) 3D printing, have enabled the customization of bone substitutes with specific shapes that match bone defect sizes and geometries. Magnesium calcium phosphate (MCP) has gained considerable attention due to its strong mechanical properties, degradability, and ability to promote bone regeneration. In this study, we prepared MCP samples with five different molar ratios via DLP 3D printing. We analyzed the physicochemical properties of these five groups, including phase compositions and microstructures, which were examined using X-ray diffraction and scanning electron microscopy, respectively. Additionally, we assessed the effects of MCP on material density and shrinkage. Biaxial flexural strength and degradation rate were evaluated; biological properties were examined through WST-8 analysis and alkaline phosphatase activity assays. Among the tested samples, MCP1/1 exhibited the highest strength. A higher proportion of magnesium phosphate in MCP corresponded to an increased degradation rate. Cell response observations in the WST-8 assay indicated that cell proliferation was better in the MCP1/1 group than in the other groups on days 4 and 7 of culturing. Alkaline phosphatase activity assays demonstrated that MCP1/1 exhibited higher activity than calcium phosphate. Our findings suggest that MCP1/1 can be used effectively in bone-tissue-engineering applications.
- Open Access
- 25 February 2025
- Published by MDPI AG in Biomimetics
- Vol. 10  (3) , 140
Effect of Axis Change on Shrinkage Rate of 3D-Printed Bioceramic Zirconia Fabricated via Digital Light Processing
Isotropic shrinkage is critical for producing dimensionally accurate prostheses using zirconia. However, the anisotropic shrinkage of 3D-printed zirconia limits its utility in clinical applications. We aimed to evaluate the impact of specimen axis alterations on the shrinkage of digital light processing (DLP)-printed zirconia. Cubes measuring 10 × 10 × 10 mm3 (similar in size to molar crowns) and cuboids measuring 10 × 10 × 20 mm (similar in size to a three-unit bridge) were manufactured using a DLP 3D printer. Zirconia specimens were pre-sintered at 1300 °C and 1400 °C. The Z-axis of some specimens was switched to the X-axis before the final sintering procedure. The X-axis, Y-axis, and Z-axis lengths of the green body, pre-sintered block, and fully sintered block were measured using digital calipers. The 3D-printed specimens showed lower shrinkage and higher deviation than the milled specimens, whose shrinkage rate was 26%. The shrinkage rates of the 3D-printed cubic specimens were 19.9% (length), 20.0% (width), and 21.99% (height), while those of the cuboidal specimens were 20.26%, 19.72%, and 21.81%, respectively. For the 3D-printed specimens, which shrink anisotropically during sintering, the axis change step had no significant impact on the shrinkage rate. In all groups, the shrinkage rate along the building direction during printing significantly exceeded that along the gravity direction during sintering.
- 25 February 2025
- Published by MDPI AG in Biomimetics
- Vol. 10  (3) , 140
Open AccessEffect of Axis Change on Shrinkage Rate of 3D-Printed Bioceramic Zirconia Fabricated via Digital Light Processing
Isotropic shrinkage is critical for producing dimensionally accurate prostheses using zirconia. However, the anisotropic shrinkage of 3D-printed zirconia limits its utility in clinical applications. We aimed to evaluate the impact of specimen axis alterations on the shrinkage of digital light processing (DLP)-printed zirconia. Cubes measuring 10 × 10 × 10 mm3 (similar in size to molar crowns) and cuboids measuring 10 × 10 × 20 mm (similar in size to a three-unit bridge) were manufactured using a DLP 3D printer. Zirconia specimens were pre-sintered at 1300 °C and 1400 °C. The Z-axis of some specimens was switched to the X-axis before the final sintering procedure. The X-axis, Y-axis, and Z-axis lengths of the green body, pre-sintered block, and fully sintered block were measured using digital calipers. The 3D-printed specimens showed lower shrinkage and higher deviation than the milled specimens, whose shrinkage rate was 26%. The shrinkage rates of the 3D-printed cubic specimens were 19.9% (length), 20.0% (width), and 21.99% (height), while those of the cuboidal specimens were 20.26%, 19.72%, and 21.81%, respectively. For the 3D-printed specimens, which shrink anisotropically during sintering, the axis change step had no significant impact on the shrinkage rate. In all groups, the shrinkage rate along the building direction during printing significantly exceeded that along the gravity direction during sintering.
- 5 October 2024
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 38  (10) , 5459-5465
Estimation of solder joint reliability in electronic packaging: Insights from finite element analysis on intermetallic compounds and voids
- 5 October 2024
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 38  (10) , 5459-5465
Estimation of solder joint reliability in electronic packaging: Insights from finite element analysis on intermetallic compounds and voids
- 5 July 2023
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 37  (7) , 1-7
Estimating elastic modulus using experimental data without strain measurement device and optimization technique of finite element analysis
- 5 July 2023
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 37  (7) , 1-7
Estimating elastic modulus using experimental data without strain measurement device and optimization technique of finite element analysis
- Open Access
- 13 April 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24  (8) , 7203
Fundamental Properties and Clinical Application of 3D-Printed Bioglass Porcelain Fused to Metal Dental Restoration
The purpose of this study is to evaluate the mechanical properties and clinical fitness of 3D-printed bioglass porcelain fused to metal (PFM) dental crowns. To evaluate the mechanical properties, tensile strength, Vickers microhardness, shear bond strength, and surface roughness tests of the SLM printed Co-Cr alloy was conducted. A right mandibular 1st molar tooth was prepared for a single dental crown (n = 10). For a three-unit metal crown and bridge, the right mandibular first premolar and first molar were prepared. Bioglass porcelain was fired to fabricate PFM dental restorations. A clinical gap was observed and measured during each of the four times porcelain was fired. A statistical analysis was conducted. The SLM technique showed the largest statistically significant tensile strength and a 0.2% yield strength value. The milling technique had the lowest statistically significant compressive strength value. The shear bond strength and surface roughness showed no statistically significant difference between the fabricated method. There was a statistically significant change in marginal discrepancy according to the porcelain firing step. The casting technique showed the greatest statistically significant margin discrepancy value. The SLM method showed better fitness than the traditional casting method and showed better mechanical properties as a dental material.
- 13 April 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24  (8) , 7203
Open AccessFundamental Properties and Clinical Application of 3D-Printed Bioglass Porcelain Fused to Metal Dental Restoration
The purpose of this study is to evaluate the mechanical properties and clinical fitness of 3D-printed bioglass porcelain fused to metal (PFM) dental crowns. To evaluate the mechanical properties, tensile strength, Vickers microhardness, shear bond strength, and surface roughness tests of the SLM printed Co-Cr alloy was conducted. A right mandibular 1st molar tooth was prepared for a single dental crown (n = 10). For a three-unit metal crown and bridge, the right mandibular first premolar and first molar were prepared. Bioglass porcelain was fired to fabricate PFM dental restorations. A clinical gap was observed and measured during each of the four times porcelain was fired. A statistical analysis was conducted. The SLM technique showed the largest statistically significant tensile strength and a 0.2% yield strength value. The milling technique had the lowest statistically significant compressive strength value. The shear bond strength and surface roughness showed no statistically significant difference between the fabricated method. There was a statistically significant change in marginal discrepancy according to the porcelain firing step. The casting technique showed the greatest statistically significant margin discrepancy value. The SLM method showed better fitness than the traditional casting method and showed better mechanical properties as a dental material.
- 28 January 2022
- Published by Elsevier in Mechanics of Materials
- Vol. 166, 104240
Mechanism of crack initiation and propagation in high-alloy steel slabs during the cooling and scarfing processes after the continuous casting process
- 28 January 2022
- Published by Elsevier in Mechanics of Materials
- Vol. 166, 104240
Mechanism of crack initiation and propagation in high-alloy steel slabs during the cooling and scarfing processes after the continuous casting process
- Open Access
- 29 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11  (17) , 8002
Optimization of Neural Network-Based Self-Tuning PID Controllers for Second Order Mechanical Systems
The feasibility of a neural network method was discussed in terms of a self-tuning proportional–integral–derivative (PID) controller. The proposed method was configured with two neural networks to dramatically reduce the number of tuning attempts with a practically achievable small amount of data acquisition. The first network identified the target system from response data, previous PID parameters, and response characteristics. The second network recommended PID parameters based on the results of the first network. The results showed that it could recommend PID parameters within 2 s of observing responses. When the number of trained data was as low as 1000, the performance efficiency of these methods was 92.9%, and the tuning was completed in an average of 2.94 attempts. Additionally, the robustness of these methods was determined by considering a system with noise or a situation when the target position was modified. These methods are also applicable for traditional PID controllers, thus enabling conservative industries to continue using PID controllers.
- 29 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11  (17) , 8002
Open AccessOptimization of Neural Network-Based Self-Tuning PID Controllers for Second Order Mechanical Systems
The feasibility of a neural network method was discussed in terms of a self-tuning proportional–integral–derivative (PID) controller. The proposed method was configured with two neural networks to dramatically reduce the number of tuning attempts with a practically achievable small amount of data acquisition. The first network identified the target system from response data, previous PID parameters, and response characteristics. The second network recommended PID parameters based on the results of the first network. The results showed that it could recommend PID parameters within 2 s of observing responses. When the number of trained data was as low as 1000, the performance efficiency of these methods was 92.9%, and the tuning was completed in an average of 2.94 attempts. Additionally, the robustness of these methods was determined by considering a system with noise or a situation when the target position was modified. These methods are also applicable for traditional PID controllers, thus enabling conservative industries to continue using PID controllers.