Micaela Almeida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Micaela Almeida has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Donald Elliot Ingber
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
3 shared publications - Nina LoGrande
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, USA
3 shared publications - Adama Marie Sesay
Wyss Institute for Biologically Inspired Engineering at Harvard University
2 shared publications - David T. Breault
Division of Endocrinology, Boston Children’s Hospital, Boston, USA
2 shared publications - Elizabeth Lee
Scripps Research 10550 N. Torrey Pines Rd.
2 shared publications Rachelle Prantil-Baun
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 17 August 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 265, 116683
Organ chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels
- 17 August 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 265, 116683
Top Cited PapersOpen AccessOrgan chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels
- 12 April 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (8) , 1584-1593
Establishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host–microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethylsiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
- 12 April 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (8) , 1584-1593
Establishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host–microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethylsiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
- Open Access
Establishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
Open AccessEstablishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.