DSDario De Simone
Dario De Simone
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dario De Simone has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Betancourt
Physik-Institut, UZH
1 shared publication - Giulio Pellegrini
Instituto de Microelectrónica de Barcelona, CNM-CSIC, Campus UAB
1 shared publication - Gregor Kramberger
University of Ljubljana
1 shared publication - Maria Manna
Centro Nacional de Microeletronica (IMB-CNM-CSIC), 08193 Barcelona, Spain
1 shared publication - Nicola Serra
Universität Zürich
1 shared publication
Latest Publications
- Open Access
- 5 February 2022
- Published by MDPI AG in Instruments
- Vol. 6 (1) , 12
Time Resolution of an Irradiated 3D Silicon Pixel Detector
We report on the measurements of time resolution for double-sided 3D pixel sensors with a single cell of 50 m 50 m and thickness of 285 m, fabricated at IMB-CNM and irradiated with reactor neutrons from 8 1MeV /cm to 1.0 1MeV /cm. The time resolution measurements were conducted using a radioactive source at a temperature of −20 and 20 °C in a bias voltage range of 50–250 V. The reference time was provided by a low gain avalanche detector produced by Hamamatsu. The results are compared to measurements conducted prior to irradiation where a temporal resolution of about 50 ps was measured. These are the first ever timing measurements on an irradiated 3D sensor and which serve as a basis for understanding their performance and to explore the possibility of performing 4D tracking in high radiation environments, such as the innermost tracking layers of future high energy physics experiments.- 5 February 2022
- Published by MDPI AG in Instruments
- Vol. 6 (1) , 12
Open AccessTime Resolution of an Irradiated 3D Silicon Pixel Detector
We report on the measurements of time resolution for double-sided 3D pixel sensors with a single cell of 50 m 50 m and thickness of 285 m, fabricated at IMB-CNM and irradiated with reactor neutrons from 8 1MeV /cm to 1.0 1MeV /cm. The time resolution measurements were conducted using a radioactive source at a temperature of −20 and 20 °C in a bias voltage range of 50–250 V. The reference time was provided by a low gain avalanche detector produced by Hamamatsu. The results are compared to measurements conducted prior to irradiation where a temporal resolution of about 50 ps was measured. These are the first ever timing measurements on an irradiated 3D sensor and which serve as a basis for understanding their performance and to explore the possibility of performing 4D tracking in high radiation environments, such as the innermost tracking layers of future high energy physics experiments.