  • Ultimate load-bearing capacity of locally buckled Class 4 I-section steel beams in moment-resisting frames under fire

    by Xiaomin Zhao, Naoya Yotsumoto, Fuminobu Ozaki, Takeo Hirashima, Kei Kimura, Yukio Murakami, Jun-Ichi Suzuki

  • Open Access

    Cyclic behavior of large tensile bolted joints for mass timber structures

    by Minami Suzuki, Marina Totsuka, Yukito Nakayama, Takeo Hirashima, Yoshihiro Yamazaki

    Owing to their high load-bearing capacity and ease of assembly, tensile-bolted joints are widely used in applications ranging from conventional wooden houses to mass timber buildings. However, the current design method contains several critical gaps that may compromise structural integrity, especially for mass timber structures under cyclic loadings: (i) disregarding cyclic effects, (ii) equating compressive yielding with splitting, and (iii) applying the embedment stiffness formula for dowel-type fasteners. Therefore, the aim of this study is to address these gaps through cyclic bending tests. All tests were conducted on column-base connections using glulam members of the same grade. Experimental results showed three failure modes of timber: compressive yielding, bending failure, and splitting failure. In specimens with longer bolt anchorage lengths, the most ductile compressive yielding was observed. The load-bearing capacity determined by compressive yielding could be predicted by the bearing strength of the material. However, regarding the bending failure, the experimental values were smaller than those calculated by the design method. This result could be attributed to both stress concentration around the specimen and the effects of cyclic loading; the latter reduced the modulus of rupture. In the case of splitting failure, although the failure moments for compressive yielding and splitting were similar, the splitting failure was more brittle. Moreover, the specimen that failed in splitting had dimensions identical to that of the specimen that failed in compressive yielding. The rotational stiffness was approximately twice the calculated values for all specimens. This discrepancy can be attributed to the underestimation of embedment stiffness beneath the washers and in the column end grain, as the current calculation is based on dowel-type fasteners. These findings emphasize the need to revise the design method to more accurately account for embedment stiffness in such joints.

  • Open Access

    Influence of laps on the behaviour of a composite slab under membrane action in fire

    by Moe Horie, Takeo Hirashima, Haruka Kanada, Yusuke Shintani, Kei Kimura

  • Open Access

    Analytical Model for Non-linear $\user2{M - }\,\,{\varvec{\theta}}$ Relationships of Dowel-Type Timber Connections Exposed to Fire

    by Yukito Nakayama, Takayuki Kikuchi, Marina Totsuka, Takeo Hirashima

    Recent experimental evidence has shown that wood–steel–wood dowel-type connections exhibit a semi-rigid behaviour even after 90 min of fire exposure. Because a semi-rigid behaviour influences the bending moment distribution among structural members, considering the moment–rotation relationships within frame analyses in which structural members are modelled as beam elements can enable a realistic fire response analysis that is significantly simpler than the three-dimensional finite element method. This study proposes an analytical methodology that accounts for the thermo-mechanical behaviour of timber and dowels, enabling the simulation of the non-linear moment–rotation relationships under fire conditions. The proposed analytical model divides dowels into a series of elements on an elastoplastic foundation and performs a direct stiffness method in a time-incremental procedure using an element stiffness matrix derived from beam-on-elastic-foundation theory. This study also presents the results of load-carrying tests on timber frames with dowel-type connections performed under ambient and fire conditions. The analytical results were consistent with the fire test results. Additionally, the analyses were also performed under three conditions in which the dowels were rigid, linear elastic, and elastoplastic bodies. These three results converged to the same value after 65 min of heating, which suggests that the ultimate states of beams with dowel-type connections exposed to fire can be modelled by assuming that dowels are rigid bodies.


  • Open Access

    MEMBRANE ACTION OF FLOOR SLABS IN FIRE (PART 3): NUMERICAL ANALYSIS OF LOAD-BEARING FIRE TESTS OF A FLOORING SYSTEM COMPOSED OF COMPOSITE SLABS AND AN UNPROTECTED STEEL BEAM

    by Eishi Mano, Takeo Hirashima, Kei Kimura

    A numerical analysis is conducted for the load-bearing fire test of flooring system composed of deck composite slabs and an unprotected secondary beam, and the test results and numerical analysis results are compared. The main aims are to verify the validity of the analytical model and to analyze the stress distribution inside the composite slab, which is difficult to obtain experimentally. In addition, the influence of the effective depth of the welding wire mesh on the deflection behavior of the slab is discussed.


  • Open Access

    Elastoplastic Analysis of Timber Connections with Dowel-Type Fasteners at Ambient and High Temperatures

    by Yuga Kawai, Marina Totsuka, Takeo Hirashima

    Three-dimensional elastoplastic finite element (FE) analysis models considering a damage zone and cleavage were developed, including plastic behavior of embedment tests parallel and perpendicular to the grain at ambient and high temperatures, in order to study the embedment behavior of timber. In a numerical analysis of compression tests to define material properties of timber, the post-yield behavior of the X-axis in the axial direction was larger than the test values when the post-yield slope of the test result were set to the plastic modulus. The reason was that the stress on the Y-axis and Z-axis increased after the yield point; thus, the equivalent yield stress decreased. In the numerical analysis of the embedment tests, the effect of the damage zone must be considered in the analytical models because the initial stiffness of the numerical results in compression parallel to the grain was considerably higher than that of the test results when the damage zone was not considered. In the numerical analysis of the embedment tests in compression perpendicular to the grain, the two models reproduced the stiffness and behavior after the yield point of the test results. The model that considered cleaving showed the stress distribution after cleavage.


  • Bending-strength evaluation of wide-flange steel beams subjected to local buckling at elevated temperatures

    by Xiaomin Zhao, Fuminobu Ozaki, Takeo Hirashima, Kei Kimura, Yukio Murakami, Jun-Ichi Suzuki, Naoya Yotsumoto

    Purpose: The main purpose of this study was to propose theoretical calculation models to evaluate the theoretical bending strengths of welded wide-flange section steel beams with local buckling at elevated temperatures.Design/methodology/approach: Steady-state tests using various test parameters, including width-thickness ratios (Class 2–4) and specimen temperatures (ambient temperature, 400, 500, 600, 700, and 800°C), were performed on 18 steel beam specimens using roller supports to examine the maximum bending moment and bending strength after local buckling. A detailed calculation model (DCM) based on the equilibrium of the axial force in the cross-section and a simple calculation model (SCM) for a practical fire-resistant design were proposed. The validity of the calculation models was verified using the bending test results.Findings: The strain concentration at the local buckling cross-section was mitigated in the elevated-temperature region, resulting in a small bending moment degradation after local buckling. The theoretical bending strengths after local buckling, evaluated from the calculation models, were in good agreement with the test results at elevated temperatures.Originality/value: The effect of local buckling on the bending behaviour after the maximum bending strength in high-temperature regions was quantified. Two types of calculation models were proposed to evaluate the theoretical bending strength after local buckling.


  • Evaluation of the fire performance of unprotected composite beams with fin-plate joints

    by Naoya Yotsumoto, Takeo Hirashima, Koji Toyoda

    Purpose: This paper aims to investigate the fire performance of composite beams when considering the hogging moment resistance of the fin-plate beam-to-girder joints including the effect of continuity of reinforcements.Design/methodology/approach: Experiments on composite beams with fin-plate joints protected only at the beam ends are conducted. The test parameter is the specification of reinforcement, which affects the rotational restraint of the beam ends. In addition, a simple method for predicting the failure time of the beam using an evaluation model based on the bending moment resistance of the beam considering the hogging moment resistance of the fin-plate joint and the reinforcement is also presented.Findings: The test results indicate that the failure time of the beam is extended by the hogging moment resistance of the joints. This is particularly noticeable when using a reinforcing bar with a large plastic deformation capability. The predicted failure times based on the evaluation method corresponded well with the test results.Originality/value: Recent studies have proposed large deformation analysis methods using FEM that can be used for fire-resistant design of beams including joints, but these cannot always be applicable in practice due to the cost and its complexity. Our method can consider the hogging moment resistance of the joint and the temperature distribution in the axial direction using a simple method without requirement of FEM.


  • Small-Scale Tests on Tensile Membrane Action of Reinforced Mortar Slabs at Elevated Temperature

    by Shiko Fukatsu, Zijing Liu, Toru Yoshida, Kenta Watanabe, Takeo Hirashima

  • Open Access

    BENDING MOMENT RESISTANCE OF COMPOSITE BEAMS PROTECTED ONLY AT THE BEAM ENDS WITH CONTINUOUS FLOOR SLAB IN FIRE

    by Naoya Yotsumoto, Takeo Hirashima, Koji Toyoda

    In the case of steel-concrete composite beams pinned with steel girders, and the beam ends are rotationally restrained by the girders, reinforcing bars in the concrete slab work effectively so that the hogging moment resistance at the pin joints can be exerted considerably. Considering this effect, there is a possibility that fire protections of the steel beams can be omitted or reduced when the load level is low. However, the hogging moment resistance at pin joints considering rebars and the influence of the rebar specification on it have not been clarified. This paper presents the results of load-bearing fire tests of composite beams protected only at the beam end with continuous floor slab conducted to clarify the hogging moment resistance at pin joints considering rebars and the influence of the rebar specification on it. 3 specimens (Pure steel beam, Composite beam using composite slab, Composite beam using RC slab) were tested, and the main test parameter was the specifications of the rebars in the concrete slab (the amount of main rebar, the type of rebar, the fixing method). The load level was 40% of the long-term allowable moment, and the heating was in accordance with ISO 834 standard curve. In this study, the hogging moment resistance of the joints and steel temperature of composite beam in fire were discussed. The main conclusions from the test results were as follows: 1) In the case of the cross section of the steel beam used in this tests, it was confirmed that the temperature of the joints during heating for 1 hour remained at about 600 ℃ by protecting at the joints using the fire resistive materials for 1 hour. 2) The pin joints have sufficient rotational ability at elevated temperature without fracture of the bolts even in bending collapse. 3) The pure steel beam with protected pin joints had the same ultimate strength as that of unprotected fixed end. 4) In the case of composite beam using RC slab, the calculated value by the evaluation model of the hogging moment resistance at pin joints considering the rebars shown in Fig. 17(d) corresponded with the experimental values well. 5) In the case of composite beam using composite slab, the rebars did not contribute to the hogging moment resistance at pin joints because the rebars were fractured at the initial stage of heating. It is necessary to evaluate the hogging moment resistance at the beam ends as simple steel beam without the effect of rebar when the rebars are fractured prematurely.