Matthias Linder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthias Linder has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- David Grundmann
Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications Hermann Reichenspurner
Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications- Moritz Seiffert
Department of Cardiology and Angiology (Medical Clinic II), University Hospital Bergmannsheil, Ruhr University Bochum , Bürkle-de-la-Camp-Platz 1, Bochum 44789
2 shared publications - Sebastian Ludwig
Department of Cardiology, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications A. Schaefer
Hamburg, Germany
1 shared publicationAndreas Schäfer
Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
1 shared publication
Latest Publications
- 8 February 2022
- Published by Elsevier in American Heart Journal
- Vol. 247, 112-122
Stroke events after transcatheter aortic valve implantation: Temporal relationships and affected brain regions
- 8 February 2022
- Published by Elsevier in American Heart Journal
- Vol. 247, 112-122
Stroke events after transcatheter aortic valve implantation: Temporal relationships and affected brain regions
- 1 January 2021
- Published by Georg Thieme Verlag KG
- Vol. 69 (S 01) , DGTHG-eP96
Comparison of Two Contemporary Balloon-Expandable Transcatheter Heart Valves: Sapien 3 versus Sapien 3 Ultra
Objectives: Transcatheter aortic valve implantation (TAVI) is an established therapy for severe aortic valve stenosis in patients at high or intermediate risk. Balloon-expandable (BE) transcatheter heart valves (THV) from the Sapien family (Edwards Lifesciences Inc., Irvine, California, USA) are among the most frequently used TAVI systems. We herein aimed to compare outcomes of patients receiving with Sapien 3 (S3) with S3 Ultra (S3U) at our center. Methods: Between 05/2018 and 05/2020, a total of 100 consecutive patients (41% female, 80.2 ± 6.7 years, logEuroSCORE I 15.7 ± 14.2%) received transfemoral TAVI using the S3 device and 100 consecutive patients (32% female, 79.8 ± 6.4 years, logEuroSCORE I 11.7 ± 10.3%) received S3U THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium (VARC-2) definitions. Result: Patients receiving a S3 THV were at significantly increased preoperative risk compared with the S3U cohort (logEuroSCORE I: S3 15.7 ± 14.2 vs. S3U 11.7 ± 10.3, p = 0.02). Device success (98 vs. 97%, p = 1.0), early safety (87 vs. 92%, p = 0.36), 30-day mortality (4 vs. 2%, p = 0.36), periprocedural stroke (2 vs. 2%, p = 1.0), myocardial Infarction (1 vs. 0%, p = 1.0), access site complications (5 vs. 3%, p = 0.72), acute kidney injury (6 vs. 1%, p = 0.12), postprocedural permanent pacemaker implantation (10 vs. 11%, p = 1.0) and postprocedural transvalvular pressure gradients (peak gradient: 20.9 ± 10.7 vs. 19.6 ± 8.3, p = 0.37; mean gradient: 10.5 ± 5.6 vs. 10.1 ± 4.7, p = 0.59) showed no significant differences between the two THV cohorts. Although rates of paravalvular leakage (PVL) ≥ moderate were not different at 30-day follow-up (1 vs. 0%, p = 1.0), incidence of mild PVL was observed more frequently in S3 patients (36 vs. 22%, p = 0.04). Conclusion: Both herein investigated THV demonstrated adequate 30-day outcomes and hemodynamic results. Comparison of the two systems revealed similar clinical results, despite a significantly higher preoperative risk profile in the S3 cohort. Incidence of mild PVL was significantly lower in the S3U cohort, which may be of particular importance for future indication of TAVI in younger patients with lower risk profiles. These results have to be confirmed in larger patient cohorts. Publication Date: 19 February 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 January 2021
- Published by Georg Thieme Verlag KG
- Vol. 69 (S 01) , DGTHG-eP96
Comparison of Two Contemporary Balloon-Expandable Transcatheter Heart Valves: Sapien 3 versus Sapien 3 Ultra
Objectives: Transcatheter aortic valve implantation (TAVI) is an established therapy for severe aortic valve stenosis in patients at high or intermediate risk. Balloon-expandable (BE) transcatheter heart valves (THV) from the Sapien family (Edwards Lifesciences Inc., Irvine, California, USA) are among the most frequently used TAVI systems. We herein aimed to compare outcomes of patients receiving with Sapien 3 (S3) with S3 Ultra (S3U) at our center. Methods: Between 05/2018 and 05/2020, a total of 100 consecutive patients (41% female, 80.2 ± 6.7 years, logEuroSCORE I 15.7 ± 14.2%) received transfemoral TAVI using the S3 device and 100 consecutive patients (32% female, 79.8 ± 6.4 years, logEuroSCORE I 11.7 ± 10.3%) received S3U THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium (VARC-2) definitions. Result: Patients receiving a S3 THV were at significantly increased preoperative risk compared with the S3U cohort (logEuroSCORE I: S3 15.7 ± 14.2 vs. S3U 11.7 ± 10.3, p = 0.02). Device success (98 vs. 97%, p = 1.0), early safety (87 vs. 92%, p = 0.36), 30-day mortality (4 vs. 2%, p = 0.36), periprocedural stroke (2 vs. 2%, p = 1.0), myocardial Infarction (1 vs. 0%, p = 1.0), access site complications (5 vs. 3%, p = 0.72), acute kidney injury (6 vs. 1%, p = 0.12), postprocedural permanent pacemaker implantation (10 vs. 11%, p = 1.0) and postprocedural transvalvular pressure gradients (peak gradient: 20.9 ± 10.7 vs. 19.6 ± 8.3, p = 0.37; mean gradient: 10.5 ± 5.6 vs. 10.1 ± 4.7, p = 0.59) showed no significant differences between the two THV cohorts. Although rates of paravalvular leakage (PVL) ≥ moderate were not different at 30-day follow-up (1 vs. 0%, p = 1.0), incidence of mild PVL was observed more frequently in S3 patients (36 vs. 22%, p = 0.04). Conclusion: Both herein investigated THV demonstrated adequate 30-day outcomes and hemodynamic results. Comparison of the two systems revealed similar clinical results, despite a significantly higher preoperative risk profile in the S3 cohort. Incidence of mild PVL was significantly lower in the S3U cohort, which may be of particular importance for future indication of TAVI in younger patients with lower risk profiles. These results have to be confirmed in larger patient cohorts. Publication Date: 19 February 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 5 April 2018
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (10) , 1245-1250
Differences in laser lead extraction of infected vs. non-infected leads
We investigated the effect of systemic infection or lead endocarditis on the complexity and the success of laser lead extraction (LLE) procedures. Medical records of all patients undergoing LLE between January 2012 and March 2017 were screened with regard to information on systemic infection or lead endocarditis. We treated 184 patients using high-frequency 80 Hz laser sheaths in patients with lead implant duration of ≥ 12 months. Indications for lead extraction were systemic infection and lead endocarditis in 52 cases (28.3%), local infection in 74 cases (40.2%), lead dysfunction in 37 cases (20.1%) and other indications in 21 cases (11.4%). 386 leads were scheduled for LLE: 235 (60.9%) pacing, 105 (27.2%) ICD and 46 (11.9%) CS leads. The mean time from initial lead implantation (systemic infection 96.8 ± 74.7 months vs. 102.1 ± 82.6 non-infected: months; p = 0.4155) and ratio of ICD leads (26.8 vs. 27.4%; p = 0.3411) did not differ significantly between the two groups. Complete procedural success was significantly higher in the systemic infection group (100 vs. 94.7%; p = 0.0077). The mean laser treatment (60.2 ± 48.7 vs. 72.4 ± 61.5 s; p = 0.2038) was numerically lower in the infection group, while fluoroscopy time (9.3 ± 7.6 vs. 12.8 ± 10.3 min; p = 0.0275) was significantly lower in this group. Minor and major complications were low in both groups and did not reveal any statistically significant difference (infected group: one minor complication; pocket hematoma, non-infected: three major complications; emergent sternotomy due to pericardial tamponade). No extraction related mortality was observed. The presence of systemic infection or lead endocarditis in LLE procedures allows for higher complete procedural success. When compared with LLE of non-infected leads, the infected leads require less laser and fluoroscopy times. Due to the scarcity of minor and major complications in general, no statistical significance was found in that regard.
- 5 April 2018
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (10) , 1245-1250
Differences in laser lead extraction of infected vs. non-infected leads
We investigated the effect of systemic infection or lead endocarditis on the complexity and the success of laser lead extraction (LLE) procedures. Medical records of all patients undergoing LLE between January 2012 and March 2017 were screened with regard to information on systemic infection or lead endocarditis. We treated 184 patients using high-frequency 80 Hz laser sheaths in patients with lead implant duration of ≥ 12 months. Indications for lead extraction were systemic infection and lead endocarditis in 52 cases (28.3%), local infection in 74 cases (40.2%), lead dysfunction in 37 cases (20.1%) and other indications in 21 cases (11.4%). 386 leads were scheduled for LLE: 235 (60.9%) pacing, 105 (27.2%) ICD and 46 (11.9%) CS leads. The mean time from initial lead implantation (systemic infection 96.8 ± 74.7 months vs. 102.1 ± 82.6 non-infected: months; p = 0.4155) and ratio of ICD leads (26.8 vs. 27.4%; p = 0.3411) did not differ significantly between the two groups. Complete procedural success was significantly higher in the systemic infection group (100 vs. 94.7%; p = 0.0077). The mean laser treatment (60.2 ± 48.7 vs. 72.4 ± 61.5 s; p = 0.2038) was numerically lower in the infection group, while fluoroscopy time (9.3 ± 7.6 vs. 12.8 ± 10.3 min; p = 0.0275) was significantly lower in this group. Minor and major complications were low in both groups and did not reveal any statistically significant difference (infected group: one minor complication; pocket hematoma, non-infected: three major complications; emergent sternotomy due to pericardial tamponade). No extraction related mortality was observed. The presence of systemic infection or lead endocarditis in LLE procedures allows for higher complete procedural success. When compared with LLE of non-infected leads, the infected leads require less laser and fluoroscopy times. Due to the scarcity of minor and major complications in general, no statistical significance was found in that regard.