James Hung
James Hung has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dan Miulli
Arrowhead Reg Med Ctr, Dept Neurosurg, Colton, CA USA
5 shared publications - James Brazdzionis
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
5 shared publications - James Wiginton
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
5 shared publications - Yongming Zhang
Medical Physics, Quasar Federal Systems, San Diego, USA
5 shared publications - Paras Savla
Department of Neurosurgery, Riverside University Health System, Moreno Valley, California, United States
4 shared publications - Tye Patchana
Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, USA
4 shared publications
Latest Publications
- Open Access
- 13 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24107
Measuring the Electromagnetic Field of Human Subjects Using Induction Sensors and a Shielded Helmet Without the Need for a Shielded Room
Neurologic activity is mediated by electrochemical signaling pathways that generate an electric charge. These electrical signals generate electromagnetic fields (EMF) that have been found to be measurable through magnetoencephalography and induction sensors. These technologies typically rely on expensive shielding via shielded rooms to remove influence from the external environment. We aimed to investigate the effects of a lightweight shielded helmet constructed of Mu-metal and interlaced copper mesh and Mu-metal EMF “channels” on shielding externally mediated EMF when measuring cortically generated EMF during human activity. Non-contact, non-invasive, proprietary induction sensors were utilized with a combination of a dual-layer Mu-metal and interlaced copper mesh helmet with sensors placed within EMF channels connected to the helmet. Five human volunteers participated in motor activities, verbalization activities, and visual object naming to evaluate the effectiveness of shielding solely via the helmet and EMF channel construct on generated EMF without placement of individuals within a shielded room. Background data without a subject were obtained. Differences in fast Fourier transformed data were noted in the background compared to rest and various activities throughout all trials. There were differences in rest phases and activity phases in each individual identifying active measurement of differences in cortically generated EMF during each activity. It appears that eliminating a Mu-metal shielded room is possible when shielding is isolated to the helmet and EMF channels with induction sensors. The external EMF was appropriately excluded with differences in background data in all trials. During the activity, differences were noted between rest phases and activity phases in all activities noting the discernibility of these induction sensors in measuring cortically generated EMF. Measured activity through motor tapping with changes between 4 and 6 Hz appeared to correlate with previously documented changes during motor activity using these sensors in conjunction with shielded rooms.
- 13 April 2022
- Published by Springer Nature in Cureus
- Vol. 14 (4) , e24107
Open AccessMeasuring the Electromagnetic Field of Human Subjects Using Induction Sensors and a Shielded Helmet Without the Need for a Shielded Room
Neurologic activity is mediated by electrochemical signaling pathways that generate an electric charge. These electrical signals generate electromagnetic fields (EMF) that have been found to be measurable through magnetoencephalography and induction sensors. These technologies typically rely on expensive shielding via shielded rooms to remove influence from the external environment. We aimed to investigate the effects of a lightweight shielded helmet constructed of Mu-metal and interlaced copper mesh and Mu-metal EMF “channels” on shielding externally mediated EMF when measuring cortically generated EMF during human activity. Non-contact, non-invasive, proprietary induction sensors were utilized with a combination of a dual-layer Mu-metal and interlaced copper mesh helmet with sensors placed within EMF channels connected to the helmet. Five human volunteers participated in motor activities, verbalization activities, and visual object naming to evaluate the effectiveness of shielding solely via the helmet and EMF channel construct on generated EMF without placement of individuals within a shielded room. Background data without a subject were obtained. Differences in fast Fourier transformed data were noted in the background compared to rest and various activities throughout all trials. There were differences in rest phases and activity phases in each individual identifying active measurement of differences in cortically generated EMF during each activity. It appears that eliminating a Mu-metal shielded room is possible when shielding is isolated to the helmet and EMF channels with induction sensors. The external EMF was appropriately excluded with differences in background data in all trials. During the activity, differences were noted between rest phases and activity phases in all activities noting the discernibility of these induction sensors in measuring cortically generated EMF. Measured activity through motor tapping with changes between 4 and 6 Hz appeared to correlate with previously documented changes during motor activity using these sensors in conjunction with shielded rooms.
- Open Access
- 29 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23626
Measuring the Electromagnetic Field of the Human Brain at a Distance Using a Shielded Electromagnetic Field Channel
The electromagnetic field (EMF) of the human brain generated by the movement of ions in the brain can be measured in a novel manner. The measurement can be completed through the skull, in a non-contact, non-invasive, continuous manner using a lightweight helmet. This investigation was conducted to determine if brain activity from movement and thoughts of movement can be measured at a distance and if that measurement can be readily evaluated at a distance using shielding with a shielded helmet and a shielded EMF channel surrounding a sensor. Non-clinical human subject volunteers donned a lightweight sensor helmet and performed a variety of specific tasks synchronized with an audible tone generated by a metronome. Constructs were created to determine if the human subjects’ brain EMF can be recorded at a distance using sensors surrounded by shielding acting similar to a waveguide in an EMF channel connected to a shielded helmet. The EMF sensors appeared to record brain electromagnetic activity as it is funneled into a shielded channel acting as a waveguide at a considerable distance including distances as far as 63 cm away. Specific brain EMFs from movement, thoughts of movement, and emotional thought can be continuously measured in a non-contact fashion at a distance using an EMF waveguide approach with an EMF channel and shielded helmet.
- 29 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23626
Open AccessMeasuring the Electromagnetic Field of the Human Brain at a Distance Using a Shielded Electromagnetic Field Channel
The electromagnetic field (EMF) of the human brain generated by the movement of ions in the brain can be measured in a novel manner. The measurement can be completed through the skull, in a non-contact, non-invasive, continuous manner using a lightweight helmet. This investigation was conducted to determine if brain activity from movement and thoughts of movement can be measured at a distance and if that measurement can be readily evaluated at a distance using shielding with a shielded helmet and a shielded EMF channel surrounding a sensor. Non-clinical human subject volunteers donned a lightweight sensor helmet and performed a variety of specific tasks synchronized with an audible tone generated by a metronome. Constructs were created to determine if the human subjects’ brain EMF can be recorded at a distance using sensors surrounded by shielding acting similar to a waveguide in an EMF channel connected to a shielded helmet. The EMF sensors appeared to record brain electromagnetic activity as it is funneled into a shielded channel acting as a waveguide at a considerable distance including distances as far as 63 cm away. Specific brain EMFs from movement, thoughts of movement, and emotional thought can be continuously measured in a non-contact fashion at a distance using an EMF waveguide approach with an EMF channel and shielded helmet.
- Open Access
- 20 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23332
Measuring Electromagnetic Field Activity Generated by Neurons In Vivo by Humans With Thoughts of Repetitive Motor Activities and Emotional Thoughts
In this study, a novel method of electromagnetic field (EMF) measurements of the human brain has been performed to evaluate neuronal activity. This measurement in a non-contact, non-invasive, continuous manner through the human skull and scalp in the standard environment is completed through a lightweight inexpensive helmet. We sought to further delineate whether specific activities of complex thought can be identified using this non-invasive technique. Non-clinical human subject volunteers donned a lightweight helmet with attached sensors and performed activities of motor movement, specific motor imagery, and specific emotional imagery synchronized to an audible tone for consistency. The human subjects’ brain EMF was recorded and analyzed. The novel method of continuously recording real-time human brain EMF was able to determine differing brain activity between individuals performing motor movement, motor imagery, and emotional imagery in a non-contact manner at different distances from the scalp. It may be possible to measure specific human brain activity using EMF in a non-invasive fashion. Emotional imagery, motor imagery, and motor movement generate different EMFs that have different discernible forms compared to baseline activity.
- 20 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23332
Open AccessMeasuring Electromagnetic Field Activity Generated by Neurons In Vivo by Humans With Thoughts of Repetitive Motor Activities and Emotional Thoughts
In this study, a novel method of electromagnetic field (EMF) measurements of the human brain has been performed to evaluate neuronal activity. This measurement in a non-contact, non-invasive, continuous manner through the human skull and scalp in the standard environment is completed through a lightweight inexpensive helmet. We sought to further delineate whether specific activities of complex thought can be identified using this non-invasive technique. Non-clinical human subject volunteers donned a lightweight helmet with attached sensors and performed activities of motor movement, specific motor imagery, and specific emotional imagery synchronized to an audible tone for consistency. The human subjects’ brain EMF was recorded and analyzed. The novel method of continuously recording real-time human brain EMF was able to determine differing brain activity between individuals performing motor movement, motor imagery, and emotional imagery in a non-contact manner at different distances from the scalp. It may be possible to measure specific human brain activity using EMF in a non-invasive fashion. Emotional imagery, motor imagery, and motor movement generate different EMFs that have different discernible forms compared to baseline activity.
- Open Access
- 9 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23006
Evaluating the Intrinsic Electromagnetic Field Generated by Neurons From Repetitive Motor Activities in Humans With a Non-contact Non-invasive Electromagnetic Helmet
The actions of neurons are dependent on electrochemical signal pathways mediated by neurotransmitters and create measurable electrical charges. These charges have been found to be measurable through neuroimaging technologies and now through a novel non-contact non-invasive sensor without supercooling. Identifying whether this technology can be appropriately interpreted with synchronized motor well-defined activities in vivo may allow for further clinical applications. A non-contact, non-invasive helmet constructed and modified using shielding technology with proprietary magnetic field sensors was utilized to measure the brain’s electromagnetic field (EMF). Human volunteers donned helmets and were asked to perform repetitive tapping exercises in order to identify waves consistent with tapping from the left and right hemispheres. A gyroscope was utilized to ensure that measured waves were not from micro-movement but were from neuronal firing. Multiple individuals were tested to evaluate the reproducibility of tapping and commonalities between individuals Right and left-sided tapping generated discernible wave changes from baseline measurements obtained by the helmet without a subject as well as differed from when the subject was at rest. Wave patterns varied from person to person but were overall similar in each subject individually. Shielding was necessary to identify signals but EMF was identified when shielding was transitioned from around the helmet to within the helmet design. It is possible to measure in-vivo electromagnetic fields generated by the human brain generated by stereotyped tasks in a non-contact non-invasive manner. These waves were reliably obtained within each individual with some variability in morphology from subject to subject however were similar in each subject. Signals varied based on activity and stereotyped motor activities were identified. A helmet using shielding technology within the helmet itself was able to effectively identify EMF signals. Future analysis may focus on translating these waves into functional mapping for clinical applications.
- 9 March 2022
- Published by Springer Nature in Cureus
- Vol. 14 (3) , e23006
Open AccessEvaluating the Intrinsic Electromagnetic Field Generated by Neurons From Repetitive Motor Activities in Humans With a Non-contact Non-invasive Electromagnetic Helmet
The actions of neurons are dependent on electrochemical signal pathways mediated by neurotransmitters and create measurable electrical charges. These charges have been found to be measurable through neuroimaging technologies and now through a novel non-contact non-invasive sensor without supercooling. Identifying whether this technology can be appropriately interpreted with synchronized motor well-defined activities in vivo may allow for further clinical applications. A non-contact, non-invasive helmet constructed and modified using shielding technology with proprietary magnetic field sensors was utilized to measure the brain’s electromagnetic field (EMF). Human volunteers donned helmets and were asked to perform repetitive tapping exercises in order to identify waves consistent with tapping from the left and right hemispheres. A gyroscope was utilized to ensure that measured waves were not from micro-movement but were from neuronal firing. Multiple individuals were tested to evaluate the reproducibility of tapping and commonalities between individuals Right and left-sided tapping generated discernible wave changes from baseline measurements obtained by the helmet without a subject as well as differed from when the subject was at rest. Wave patterns varied from person to person but were overall similar in each subject individually. Shielding was necessary to identify signals but EMF was identified when shielding was transitioned from around the helmet to within the helmet design. It is possible to measure in-vivo electromagnetic fields generated by the human brain generated by stereotyped tasks in a non-contact non-invasive manner. These waves were reliably obtained within each individual with some variability in morphology from subject to subject however were similar in each subject. Signals varied based on activity and stereotyped motor activities were identified. A helmet using shielding technology within the helmet itself was able to effectively identify EMF signals. Future analysis may focus on translating these waves into functional mapping for clinical applications.
- Open Access
- 7 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e21982
Novel Method of Electromagnetic Field Measurements of the Human Brain
Advancements in neuroimaging have changed the field of medicine. Computed tomography (CT) and magnetic resonance imaging (MRI) typically produce a static image of the brain, while continuous electroencephalogram (EEG) data is limited to the cortical surface. The brain’s chemical reactions produce an electric circuit that generates a magnetic field. We seek to test the ability of a non-contact sensor to measure the human brain’s electromagnetic field (EMF). A lightweight, inexpensive construct was designed to hold EMF sensors to non-invasively measure the human brain’s dynamic EMF. Measurements were conducted on non-clinical human volunteers. Background data without the human subjects was obtained, followed by introducing human subjects. Motionless human subject data was obtained, followed by a subject performing a task. Finally, a subject received auditory stimulation, and data was obtained. Our non-contact sensor was able to detect a difference between background activity without a human subject and the electromagnetic field of a human brain within the scalp and skull. Detectable differences in magnetic field potential were also obtained when the subject performed a task and received auditory stimulation. It is possible to continuously measure living human brain dynamic electromagnetic fields throughout the entire brain in a non-contact, non-invasive, continuous manner through the human scalp and skull in the standard environment. The signals are unique to the individual human and can be differentiated from background activity.
- 7 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e21982
Open AccessNovel Method of Electromagnetic Field Measurements of the Human Brain
Advancements in neuroimaging have changed the field of medicine. Computed tomography (CT) and magnetic resonance imaging (MRI) typically produce a static image of the brain, while continuous electroencephalogram (EEG) data is limited to the cortical surface. The brain’s chemical reactions produce an electric circuit that generates a magnetic field. We seek to test the ability of a non-contact sensor to measure the human brain’s electromagnetic field (EMF). A lightweight, inexpensive construct was designed to hold EMF sensors to non-invasively measure the human brain’s dynamic EMF. Measurements were conducted on non-clinical human volunteers. Background data without the human subjects was obtained, followed by introducing human subjects. Motionless human subject data was obtained, followed by a subject performing a task. Finally, a subject received auditory stimulation, and data was obtained. Our non-contact sensor was able to detect a difference between background activity without a human subject and the electromagnetic field of a human brain within the scalp and skull. Detectable differences in magnetic field potential were also obtained when the subject performed a task and received auditory stimulation. It is possible to continuously measure living human brain dynamic electromagnetic fields throughout the entire brain in a non-contact, non-invasive, continuous manner through the human scalp and skull in the standard environment. The signals are unique to the individual human and can be differentiated from background activity.