Heba Yuksel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Heba Yuksel has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Christopher C. Davis
Univ. of Maryand, College Park (United States)
4 shared publications- Erman Kibritoglu
Department of Electrical and Electronics Engineering, Bogazici University , Bebek, Istanbul 34342
4 shared publications - Azad Ozan Korkan
Department of Electrical and Electronics Engineering, Bogazici University, Istanbul 34342, Türkiye
3 shared publications - Ahmet Deniz
Department of Electrical and Electronics Engineering, Bogazici University, Bebek 34342, Istanbul, Turkey
2 shared publications Demet Yuksel
Bogaziçi Univ. (Turkey)
2 shared publicationsGülşen Kösoğlu
Department of Physics, Boğaziçi University, Bebek, Istanbul 34342, Turkey
2 shared publications
Latest Publications
- Open Access
A High-Resolution FPGA-Based Time-to-Amplitude Converter (TAC) with Integrated Pulse-Width-Based Walk Error Compensation: Design and Experimental LiDAR Validation
LiDAR is a key sensor for depth perception in applications ranging from autonomous vehicles and industrial robotics to robotic vacuum cleaners and topographic mapping, with its depth resolution determined by the timing electronics. This article, to the best of our knowledge, presents the first implementation of an FPGA-based time-to-amplitude converter (TAC) in a LiDAR system alongside the first integration of walk error compensation into such an architecture. The threshold-crossing time shifts with the echo amplitude, causing walk error. This walk error can reach tens of centimeters depending on target reflectivity and range. Pulse-width-based correction has been demonstrated, but reported implementations obtain the time-of-flight (ToF) and the pulse width with time-to-digital converters (TDCs), whose high resolution relies on high-speed clocks for coarse time and delay lines for fine-time measurements, which suffer from coarse-count ambiguity, bin calibration requirements, sensitivity to process, voltage, and temperature (PVT) variations, and portability limitations. This article enhances the novel FPGA-based TAC previously introduced by the authors for pulse-width-based walk error compensation without using a clock or a delay line. Each ToF channel requires only one D flip-flop in the FPGA and a low-cost external passive circuit coupled to the multichannel analog-to-digital converter (ADC) of the FPGA. Using our FPGA-based TAC in our LiDAR experimental setup, the walk-induced distance error is successfully reduced from 42 cm to 2 cm, and target distances of up to 3 m are measured within a 2 cm maximum error.
Open AccessA High-Resolution FPGA-Based Time-to-Amplitude Converter (TAC) with Integrated Pulse-Width-Based Walk Error Compensation: Design and Experimental LiDAR Validation
LiDAR is a key sensor for depth perception in applications ranging from autonomous vehicles and industrial robotics to robotic vacuum cleaners and topographic mapping, with its depth resolution determined by the timing electronics. This article, to the best of our knowledge, presents the first implementation of an FPGA-based time-to-amplitude converter (TAC) in a LiDAR system alongside the first integration of walk error compensation into such an architecture. The threshold-crossing time shifts with the echo amplitude, causing walk error. This walk error can reach tens of centimeters depending on target reflectivity and range. Pulse-width-based correction has been demonstrated, but reported implementations obtain the time-of-flight (ToF) and the pulse width with time-to-digital converters (TDCs), whose high resolution relies on high-speed clocks for coarse time and delay lines for fine-time measurements, which suffer from coarse-count ambiguity, bin calibration requirements, sensitivity to process, voltage, and temperature (PVT) variations, and portability limitations. This article enhances the novel FPGA-based TAC previously introduced by the authors for pulse-width-based walk error compensation without using a clock or a delay line. Each ToF channel requires only one D flip-flop in the FPGA and a low-cost external passive circuit coupled to the multichannel analog-to-digital converter (ADC) of the FPGA. Using our FPGA-based TAC in our LiDAR experimental setup, the walk-induced distance error is successfully reduced from 42 cm to 2 cm, and target distances of up to 3 m are measured within a 2 cm maximum error.
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Non-contact dielectrophoretic forcing of particle-laden flow: Momentum transfer and flow modulation in a blood-mimicking suspension
Dielectrophoresis (DEP) provides a non-contact forcing mechanism for polarizable particles suspended in non-uniform electric fields. While DEP is commonly used for particle manipulation, trapping, and separation, its role as a distributed hydrodynamic forcing mechanism in particle-laden suspension flow remains less explored. This study investigates DEP-assisted flow modulation in a diluted glycerol–SiO2 suspension used as a controllable blood-mimicking particle-laden phantom. The fracture-healing context provides the transport motivation, whereas the central focus is the particle–fluid momentum-transfer mechanism. Three external coil geometries, Catenary, Lintearia, and Valeria, were evaluated at excitation currents of 0.50, 0.75, and 1.00 A, respectively. DEP-induced particle forcing was interpreted through a momentum-transfer framework, in which particle acceleration, particle–fluid slip, and viscous coupling contribute to macroscopic flow enhancement. The displaced volume was treated as an integral flow response relative to a nominal 100 ml no-DEP baseline. The results showed a clear coil- and current-dependent enhancement. At 0.75 A, displaced volumes of 120±4, 140±6, and 200±10 ml were obtained for the Catenary, Lintearia, and Valeria coils, respectively. The strongest response occurred for the Valeria coil at 1.00 A, reaching 215±9 ml. Model predictions agreed closely with experiments, with a root-mean square error (RMSE) of 5.14 ml, a mean absolute error (MAE) of 4.22 ml, a maximum absolute error (MaxAE) of 8.00 ml, and a Pearson correlation coefficient of r=0.995. These findings demonstrate that DEP can modulate particle-laden suspension flow through field-induced particle forcing and hydrodynamic momentum transfer.
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Non-contact dielectrophoretic forcing of particle-laden flow: Momentum transfer and flow modulation in a blood-mimicking suspension
Dielectrophoresis (DEP) provides a non-contact forcing mechanism for polarizable particles suspended in non-uniform electric fields. While DEP is commonly used for particle manipulation, trapping, and separation, its role as a distributed hydrodynamic forcing mechanism in particle-laden suspension flow remains less explored. This study investigates DEP-assisted flow modulation in a diluted glycerol–SiO2 suspension used as a controllable blood-mimicking particle-laden phantom. The fracture-healing context provides the transport motivation, whereas the central focus is the particle–fluid momentum-transfer mechanism. Three external coil geometries, Catenary, Lintearia, and Valeria, were evaluated at excitation currents of 0.50, 0.75, and 1.00 A, respectively. DEP-induced particle forcing was interpreted through a momentum-transfer framework, in which particle acceleration, particle–fluid slip, and viscous coupling contribute to macroscopic flow enhancement. The displaced volume was treated as an integral flow response relative to a nominal 100 ml no-DEP baseline. The results showed a clear coil- and current-dependent enhancement. At 0.75 A, displaced volumes of 120±4, 140±6, and 200±10 ml were obtained for the Catenary, Lintearia, and Valeria coils, respectively. The strongest response occurred for the Valeria coil at 1.00 A, reaching 215±9 ml. Model predictions agreed closely with experiments, with a root-mean square error (RMSE) of 5.14 ml, a mean absolute error (MAE) of 4.22 ml, a maximum absolute error (MaxAE) of 8.00 ml, and a Pearson correlation coefficient of r=0.995. These findings demonstrate that DEP can modulate particle-laden suspension flow through field-induced particle forcing and hydrodynamic momentum transfer.
- 29 May 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 655
Accelerating bone fracture healing using magnetophoretic forces: A numerical analysis
- 29 May 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 655
Accelerating bone fracture healing using magnetophoretic forces: A numerical analysis
- Open Access
- 20 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 364
SAR-Based Thermal Assessment of Dielectrophoretic Pulsed Electromagnetic Stimulation in Tibia Fractures with Metallic Implants
Electromagnetic field-based stimulation has emerged as a promising noninvasive approach for enhancing bone fracture healing. Beyond conventional pulsed electromagnetic field (PEMF) therapies employing spatially uniform fields, dielectrophoretic-force-based (DEPF) stimulation exploits electromagnetic field non-uniformities to induce localized interactions to enhance fracture healing. However, the thermal behavior associated with DEPF-driven PEMF exposure in the presence of metallic orthopedic implants remains largely unexplored. In this study, the thermal response of tissue-like tibia phantoms with and without metallic implants is investigated using an integrated experimental and numerical framework. A custom-designed conical coil is employed to generate non-uniform DEPF excitation capable of affecting the fracture site. Surface temperature evolution is measured using infrared thermal imaging, while electromagnetic power absorption is quantified through specific absorption rate (SAR)-based thermal measurement coupled with a bio-heat formulation. Anatomically realistic tibia phantoms reconstructed from computed tomography data are fabricated via a 3D printer to represent clinically relevant fracture configurations. Experimental results show that the metallic implant exhibits a rapid temperature increase of approximately within the first few minutes of exposure, followed by thermal stabilization, corresponding to an effective absorbed power of inferred from the initial temperature slope. In contrast, the non-conductive resin phantom displays a temperature rise of only over the same interval, yielding . These findings demonstrate that implant-related eddy-current losses dominate localized heating under DEPF excitation, while tissue-like media remain weakly affected. This work provides SAR-based experimental evaluation of DEPF stimulation in implanted tibia fracture models, offering new insight into implant-induced electromagnetic heating and its implications for the safety and optimization of DEPF-based bone-healing therapies.- 20 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 364
Open AccessSAR-Based Thermal Assessment of Dielectrophoretic Pulsed Electromagnetic Stimulation in Tibia Fractures with Metallic Implants
Electromagnetic field-based stimulation has emerged as a promising noninvasive approach for enhancing bone fracture healing. Beyond conventional pulsed electromagnetic field (PEMF) therapies employing spatially uniform fields, dielectrophoretic-force-based (DEPF) stimulation exploits electromagnetic field non-uniformities to induce localized interactions to enhance fracture healing. However, the thermal behavior associated with DEPF-driven PEMF exposure in the presence of metallic orthopedic implants remains largely unexplored. In this study, the thermal response of tissue-like tibia phantoms with and without metallic implants is investigated using an integrated experimental and numerical framework. A custom-designed conical coil is employed to generate non-uniform DEPF excitation capable of affecting the fracture site. Surface temperature evolution is measured using infrared thermal imaging, while electromagnetic power absorption is quantified through specific absorption rate (SAR)-based thermal measurement coupled with a bio-heat formulation. Anatomically realistic tibia phantoms reconstructed from computed tomography data are fabricated via a 3D printer to represent clinically relevant fracture configurations. Experimental results show that the metallic implant exhibits a rapid temperature increase of approximately within the first few minutes of exposure, followed by thermal stabilization, corresponding to an effective absorbed power of inferred from the initial temperature slope. In contrast, the non-conductive resin phantom displays a temperature rise of only over the same interval, yielding . These findings demonstrate that implant-related eddy-current losses dominate localized heating under DEPF excitation, while tissue-like media remain weakly affected. This work provides SAR-based experimental evaluation of DEPF stimulation in implanted tibia fracture models, offering new insight into implant-induced electromagnetic heating and its implications for the safety and optimization of DEPF-based bone-healing therapies. - 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
A 32-Channel, Low Resources and High-Precision FPGA Time-to-Digital Converter (TDC) Based on Dynamic Phase Shifting (DPS) for 3-D LiDAR Applications
This article demonstrates a low-cost, low-resource field-programmable gate array (FPGA) time-to-digital converter (TDC) method based on dynamic phase shifting (DPS) and high-speed counters with adjustable resolution down to 14.9 ps for 3D light detection and ranging (LiDAR) applications requiring multichannel TDCs. Delay line-based FPGA TDCs, such as tapped delay line implementations, provide excellent resolution. However, their high resource utilization and the need for detailed bin-by-bin online calibration limit multichannel implementation on low-cost FPGAs. Multiphase clock counter-based FPGA TDCs are a good alternative in terms of low resource consumption, but their resolution is noticeably lower than that of delay line-based FPGA TDCs. The proposed DPS-based FPGA TDC method achieves low resource consumption while maintaining high resolution and precision. To demonstrate the suitability of the proposed DPS-based FPGA TDC for multichannel operation, we implemented 32 TDC channels performing simultaneous pulse-width and time-off-flight (TOF) measurements. The proposed 32-channel DPS-based FPGA TDC consumes very low resources, requiring only 2519 look-up tables (LUTs) and 2700 D flip-flops (DFFs), corresponding to 3.97% of the LUTs and 2.13% of the DFFs of our low-cost AMD Xilinx XC7A100T-1CSG324C FPGA. In addition, only 70 LUTs and 68 DFFs are required for each additional channel. In addition to low resource consumption, the proposed method achieves high-performance TOF measurements with a precision of 11–16 ps and high linearity, with integral nonlinearity (INL) values between −0.57 and 0.67 least significant bit (LSB) and differential nonlinearity (DNL) values between −0.8 and 0.82 LSB, where the LSB is as small as 10 ps. We believe that the high precision and low resource utilization of the proposed DPS-based FPGA TDC will be a promising solution to design low-cost 3D LiDARs requiring high performance multichannel TDCs on a single chip.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
A 32-Channel, Low Resources and High-Precision FPGA Time-to-Digital Converter (TDC) Based on Dynamic Phase Shifting (DPS) for 3-D LiDAR Applications
This article demonstrates a low-cost, low-resource field-programmable gate array (FPGA) time-to-digital converter (TDC) method based on dynamic phase shifting (DPS) and high-speed counters with adjustable resolution down to 14.9 ps for 3D light detection and ranging (LiDAR) applications requiring multichannel TDCs. Delay line-based FPGA TDCs, such as tapped delay line implementations, provide excellent resolution. However, their high resource utilization and the need for detailed bin-by-bin online calibration limit multichannel implementation on low-cost FPGAs. Multiphase clock counter-based FPGA TDCs are a good alternative in terms of low resource consumption, but their resolution is noticeably lower than that of delay line-based FPGA TDCs. The proposed DPS-based FPGA TDC method achieves low resource consumption while maintaining high resolution and precision. To demonstrate the suitability of the proposed DPS-based FPGA TDC for multichannel operation, we implemented 32 TDC channels performing simultaneous pulse-width and time-off-flight (TOF) measurements. The proposed 32-channel DPS-based FPGA TDC consumes very low resources, requiring only 2519 look-up tables (LUTs) and 2700 D flip-flops (DFFs), corresponding to 3.97% of the LUTs and 2.13% of the DFFs of our low-cost AMD Xilinx XC7A100T-1CSG324C FPGA. In addition, only 70 LUTs and 68 DFFs are required for each additional channel. In addition to low resource consumption, the proposed method achieves high-performance TOF measurements with a precision of 11–16 ps and high linearity, with integral nonlinearity (INL) values between −0.57 and 0.67 least significant bit (LSB) and differential nonlinearity (DNL) values between −0.8 and 0.82 LSB, where the LSB is as small as 10 ps. We believe that the high precision and low resource utilization of the proposed DPS-based FPGA TDC will be a promising solution to design low-cost 3D LiDARs requiring high performance multichannel TDCs on a single chip.
- 24 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110213
Numerical analysis of coil designs to expedite fracture healing using dielectrophoresis with S method
- 24 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110213
Numerical analysis of coil designs to expedite fracture healing using dielectrophoresis with S method
- Open Access
- 23 October 2024
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 13 (6) , 69
Enhancing Signal-to-Noise Ratio in Vehicle-to-Vehicle Visible Light Communication Systems Through Diverse LED Array Transmitter Geometries
In this paper, a novel method is introduced to enhance the performance of vehicle-to-vehicle (V2V) visible light communication (VLC) by employing different transmitter (Tx) light-emitting diode (LED) array arrangements with different LED orientations. Improving the signal-to-noise ratio (SNR) is crucial for V2V VLC systems to provide long communication ranges. For this purpose, six transmitter configurations are proposed: single-LED transmitters, as well as 3 × 3 square-, single hexagonal-, octagonal-, 5 × 5 square-, and honeycomb hexagonal-shaped LED arrays. Indoor VLC studies using LED arrays offer a uniform SNR, while outdoor studies focus on optimizing the receiver side to enhance system performance. This paper optimizes system performance by increasing the SNR and communication range of V2V VLC systems by changing the geometry of the Tx LED array and LED orientations. A V2V VLC system using on–off keying (OOK) is modeled in MATLAB, and the SNR and bit error rate (BER) are simulated for different Tx configurations. Our results show that the honeycomb hexagonal transmitter design provides a 19% improvement in system performance with a spacing of 1 cm, and maintains a 16% improvement when the array size is reduced by a factor of 100, making it smaller than one of the smallest industrial headlight modules.
- 23 October 2024
- Published by MDPI AG in Journal of Sensor and Actuator Networks
- Vol. 13 (6) , 69
Open AccessEnhancing Signal-to-Noise Ratio in Vehicle-to-Vehicle Visible Light Communication Systems Through Diverse LED Array Transmitter Geometries
In this paper, a novel method is introduced to enhance the performance of vehicle-to-vehicle (V2V) visible light communication (VLC) by employing different transmitter (Tx) light-emitting diode (LED) array arrangements with different LED orientations. Improving the signal-to-noise ratio (SNR) is crucial for V2V VLC systems to provide long communication ranges. For this purpose, six transmitter configurations are proposed: single-LED transmitters, as well as 3 × 3 square-, single hexagonal-, octagonal-, 5 × 5 square-, and honeycomb hexagonal-shaped LED arrays. Indoor VLC studies using LED arrays offer a uniform SNR, while outdoor studies focus on optimizing the receiver side to enhance system performance. This paper optimizes system performance by increasing the SNR and communication range of V2V VLC systems by changing the geometry of the Tx LED array and LED orientations. A V2V VLC system using on–off keying (OOK) is modeled in MATLAB, and the SNR and bit error rate (BER) are simulated for different Tx configurations. Our results show that the honeycomb hexagonal transmitter design provides a 19% improvement in system performance with a spacing of 1 cm, and maintains a 16% improvement when the array size is reduced by a factor of 100, making it smaller than one of the smallest industrial headlight modules.
- Open Access
An Empirical Approach to Rerouting Visible Light Pathways Using an Adjustable-Angle Mirror to Sustain Communication between Vehicles on Curvy Roads
In this paper, a novel method is demonstrated to sustain vehicle-to-vehicle (V2V) communication on curvy roads via the arrangement of the lateral position of a self-angle-adjustable mirror–reflective road sign (SAAMRS) and light-direction-sensing wide-angle complementary photodiodes (CPDs). Visible light communication (VLC) between vehicles attracts attention as a complementary technology to radio-frequency-based (RF-based) communication technologies due to its wide, license-free spectrum and immunity to interferences. However, V2V VLC may be interrupted on curvy roads due to the limited field of view (FOV) of the receiver or the line of sight (LOS) being interrupted. To solve this problem, an experiment was developed using an SAAMRS along with wide-angle light-direction-sensing CPDs that used a precise peak detection (PPD) method to sustain communication between vehicles in dynamic environments by rerouting the incident light with the highest signal intensity level to the receiver vehicle on curvy roads. We also used real images of curvy roads simulated as polynomials to calculate the necessary rotation angles for the SAAMRS and regions where communication exist. Our experimental results overlapped almost completely with our simulations, with small errors of approximately 4.8% and 4.4% for the SAAMRS angle and communication region, respectively.
Open AccessAn Empirical Approach to Rerouting Visible Light Pathways Using an Adjustable-Angle Mirror to Sustain Communication between Vehicles on Curvy Roads
In this paper, a novel method is demonstrated to sustain vehicle-to-vehicle (V2V) communication on curvy roads via the arrangement of the lateral position of a self-angle-adjustable mirror–reflective road sign (SAAMRS) and light-direction-sensing wide-angle complementary photodiodes (CPDs). Visible light communication (VLC) between vehicles attracts attention as a complementary technology to radio-frequency-based (RF-based) communication technologies due to its wide, license-free spectrum and immunity to interferences. However, V2V VLC may be interrupted on curvy roads due to the limited field of view (FOV) of the receiver or the line of sight (LOS) being interrupted. To solve this problem, an experiment was developed using an SAAMRS along with wide-angle light-direction-sensing CPDs that used a precise peak detection (PPD) method to sustain communication between vehicles in dynamic environments by rerouting the incident light with the highest signal intensity level to the receiver vehicle on curvy roads. We also used real images of curvy roads simulated as polynomials to calculate the necessary rotation angles for the SAAMRS and regions where communication exist. Our experimental results overlapped almost completely with our simulations, with small errors of approximately 4.8% and 4.4% for the SAAMRS angle and communication region, respectively.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
A Novel Time-to-Amplitude Converter and a Low-Cost Wide Dynamic Range FPGA TDC for LiDAR Application
This article demonstrates a low-cost wide dynamic range field-programmable gate array (FPGA) time-to-digital converter (TDC) and a time-to-amplitude converter (TAC) based on an embedded XOR gate of the FPGA and a low-complexity circuitry. TACs and TDCs are important for distance measurements in light detection and ranging (LiDAR) systems in a wide range of applications from self-driving cars to topographic mapping. LiDAR’s high cost, relatively large size, and complexity are important implementation challenges that need to be addressed. In the literature, external circuits are used to provide low phase noise clock signals into the FPGA TDC to measure long-range time intervals adding to the complexity and cost. Our TDC can measure a wide dynamic range of 1 ms with high precision using a low-cost FPGA board. Calibration using dynamic phase-shifting (DPS) is conducted with a resolution of 18 ps. The performance measurements gave us insight on the relative temperature insensitive regions for operating the TDC. The ideal range was found to be 24 °C–39 °C. We also present a novel TAC design to demonstrate that one XOR gate of a low-cost Artix-7 FPGA and a simple low-cost circuitry can detect a phase difference as low as 18 ps. The TAC’s linearity is presented through integral nonlinearity (INL) and differential nonlinearity (DNL) test results. For every additional channel, our TAC requires only one XOR gate in the FPGA chip and a low complexity circuitry. This allows for multichannel operation and larger area availability for use in other implementations. Performance measurements show our TAC to be highly insensitive to temperature and voltage changes.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
A Novel Time-to-Amplitude Converter and a Low-Cost Wide Dynamic Range FPGA TDC for LiDAR Application
This article demonstrates a low-cost wide dynamic range field-programmable gate array (FPGA) time-to-digital converter (TDC) and a time-to-amplitude converter (TAC) based on an embedded XOR gate of the FPGA and a low-complexity circuitry. TACs and TDCs are important for distance measurements in light detection and ranging (LiDAR) systems in a wide range of applications from self-driving cars to topographic mapping. LiDAR’s high cost, relatively large size, and complexity are important implementation challenges that need to be addressed. In the literature, external circuits are used to provide low phase noise clock signals into the FPGA TDC to measure long-range time intervals adding to the complexity and cost. Our TDC can measure a wide dynamic range of 1 ms with high precision using a low-cost FPGA board. Calibration using dynamic phase-shifting (DPS) is conducted with a resolution of 18 ps. The performance measurements gave us insight on the relative temperature insensitive regions for operating the TDC. The ideal range was found to be 24 °C–39 °C. We also present a novel TAC design to demonstrate that one XOR gate of a low-cost Artix-7 FPGA and a simple low-cost circuitry can detect a phase difference as low as 18 ps. The TAC’s linearity is presented through integral nonlinearity (INL) and differential nonlinearity (DNL) test results. For every additional channel, our TAC requires only one XOR gate in the FPGA chip and a low complexity circuitry. This allows for multichannel operation and larger area availability for use in other implementations. Performance measurements show our TAC to be highly insensitive to temperature and voltage changes.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Experimental Optical Setup to Measure Power Loss versus Fiber Bent Radius for Tapping into Optical Fiber Communication Links
Optical fiber communication was widely believed that an optical network was a good way to prevent hacking through wiretaps which intercept network data. However, fiber optic cable is not particularly secure. Various tapping methods can be used to extract data from fiber optic networks with little or no risk of detection. One of the easiest ways of intruding into a fiber optic communication link is creating a bend on the fiber cable. Even small percentage of the transmitted light acquired with the bending method is enough for recovering the data by the attacker. Though there are some techniques and devices that can track the power and intensity inside the fiber cable, these methods cannot detect an attack exploiting small leakage. Therefore, it is critical to determine a range of radii of curvature for which tapping attacks are not detectable. Though there are some studies to quantify the power loss both theoretically and numerically, as of the authors' knowledge, there has not been any experimental validation of those studies. In this respect, an experimental optical setup and a technique relying on the ADC conversion capability of Arduino UNO to measure power loss resulting from different bending radii are proposed in this paper. A lower limit for radius of curvature for an attack to be undetected is obtained and the estimations in the literature for power loss resulting from fiber bending is validated.
- 9 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Experimental Optical Setup to Measure Power Loss versus Fiber Bent Radius for Tapping into Optical Fiber Communication Links
Optical fiber communication was widely believed that an optical network was a good way to prevent hacking through wiretaps which intercept network data. However, fiber optic cable is not particularly secure. Various tapping methods can be used to extract data from fiber optic networks with little or no risk of detection. One of the easiest ways of intruding into a fiber optic communication link is creating a bend on the fiber cable. Even small percentage of the transmitted light acquired with the bending method is enough for recovering the data by the attacker. Though there are some techniques and devices that can track the power and intensity inside the fiber cable, these methods cannot detect an attack exploiting small leakage. Therefore, it is critical to determine a range of radii of curvature for which tapping attacks are not detectable. Though there are some studies to quantify the power loss both theoretically and numerically, as of the authors' knowledge, there has not been any experimental validation of those studies. In this respect, an experimental optical setup and a technique relying on the ADC conversion capability of Arduino UNO to measure power loss resulting from different bending radii are proposed in this paper. A lower limit for radius of curvature for an attack to be undetected is obtained and the estimations in the literature for power loss resulting from fiber bending is validated.